American Power Conversion MX28B400 user manual Introduction, General Information

Page 6

2 Introduction

2.1. General Information

Power Plants from APC have unique features that make them easy to install, maintain, and upgrade. The rectifier units are modular and truly “hot-pluggable” into the shelf assembly without any separate ac wiring. All system settings are made from the system control unit that provides monitoring and control functions for each component of the system as well as alarm listings for system diagnosis and maintenance.

The APC Model MX28B is a modular stand-alone + 24 Vdc power plant. It is configurable in such a manner that it will support most typical applications within the specified current ranges (400 amperes) without special application engineering or assistance. Distribution is included for up to 24 plug-in circuit breakers. These circuit breakers can be 1 to 100 amps, with 60-100 amp breakers requiring two positions and a circuit breaker adapter kit. An optional low voltage disconnect (LVD) can be provided on either the battery or the load side. An MX28B is shown in Figure 2.1-1. A system wiring diagram is shown in Figure 2.1-2.

Figure 2.1-1 MX28B-400 +24 Vdc Power Plant (with circuit breaker cover removed)

MX28B400 +24 VDC User’s Manual

Page 2

Image 6
Contents Page Table of Contents Remote Monitoring Revision History Revision Date DescriptionSafety First General PrecautionsIntroduction General Information2 MX28B-400 +24 Vdc System Wiring Diagram with Battery LVD How to Use This Manual Unpacking Equipment InstallationMechanical Installation Room / LocationAC Power Connections VentilationBattery Connections Planning the Battery installationConnecting the Cables Battery Temperature Probe Installation 2 Battery Temperature Probe InstallationDC System Grounding DC Power Output Over-Current Protection DC Circuit BreakersBreaker Part Number Adaptor Size Rating Plug-in Circuit Breaker Installation Load Cable Size ConsiderationsCircuit Breaker Connections 1 to 50 Amps Circuit Breaker Connections 60-100 AmpsFront Panel DB9 Connection Monitoring and Relay Output ConnectionsGMT Fuse Option Smart Cable DB9 ConnectionRJ45 Ethernet Connector Relay Output ConnectionsExternal Alarm Input Connections NO-NC-CRectifier Module Installation Initial Power-Up and CheckoutSystem Parameters Verification/Adjustment Battery Maximum Recharge Rate default = 12AFull System Power Up Operation Technical DescriptionRectifier Management System Output Capacity System Status and Alarm ReportingSystem Management System Voltage ControlBattery Temperature Compensation Battery ManagementBattery Charging and Protection DC DistributionControls and Indicators Battery/Load Low Voltage DisconnectFront Panel User Interface Status Alarms System Modules Batt PIN OEM Parameter Locations, Descriptions, and Default ValuesAddress Alarm ItemNo Alarms Switzer AvBatt Max Rechm+ Minor22.00 50 aComp TC Comp LkneeComp Method m+ 00mVHw Batt T Almm+ Fuse 1 AlmHw Batt C Almm+ Hw LVD AlmLamp Test DisableLVD Reset LVD OptionOut-Rly 1 Dly m+ Out-RlyRelay SecRect 1 Curr Rect CL AlmRect 1 CL 24.9Store Cfg Rect Stdby Almm+Rect 1 Stdby Sys CurrentSys Voltage Sys Temp26.7 Test Maj RlyStatus Alarms Control Unit Menu StructureV e l C o n d L e v e l I r d L e v e l U r t h L e v e l Sysout AP Alias MOD Modrec EM Modules Batt Rect Conv CIR SET-ALM Param MOD Modcir MOD Modlvd MT LVD SET-ALM Param Front Panel LED Indicators Alarm Outputs Output Relays External Alarm Inputs Input RelaysDescription Command and Monitoring ProtocolRemote Monitoring Physical Connections1MRF28H27BV Rectifiers SpecificationsAC Input 1MRF28H27BV50 RectifiersDC Output with either Rectifier RectifiersPower Shelf Control Unit PscuMechanical EnvironmentalCompliance APC Worldwide Customer Support Limited Product Warranty