Maintenance and Troubleshooting | |
|
|
| Use Your |
Provide | Other Hand to |
Gently Bend | |
Support |
|
At Rivets |
|
Figure 4-1: Adjusting the Thermocouple
Once installed, the critical point of the thermocouple
MUST make direct contact with the roll as shown in
Figure
Bend
Rivets
Thermal
Junction
Roll
Figure 4-2: Correct Thermocouple Contact
CAUTION
Firmly hold the thermocouple where the “guitar
pick” sensor is riveted to the aluminum base while bending. You can break the sensor off the base if you do not provide this added support.
5.Replace the thermocouple and tighten the screws.
6.Repeat the procedure for the other thermocouple.