5.KEY LAYOUT

5.1 PROGRAMMING KEYBOARD

5. KEY LAYOUT

5.1 PROGRAMMING KEYBOARD

 

 

 

 

 

CLEAR

SHIFT

SET

NEXT

AUTO

 

 

 

 

 

NEXT

PLU

CODE

 

 

 

 

 

 

 

 

 

 

SEND

RECEIVE

CHANGE

DELETE

RETURN

 

 

 

PLU

PLU

1/4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DELETE

INSERT

DELETE

PROG.

ENTER

TEST

(A)

 

(B)

 

 

 

 

 

 

 

1/2

1

 

!

#

$

%

&

´

?

@

1

2

3

4

5

6

7

8

9

0

*

+

(

)

/

:

;

<

=

>

Q

W

E

R

T

Y

U

I

O

P

[

`

]

^

{

:

}

 

A

S

D

F

G

H

J

K

L

È

É

Â

Ê

Z

X

C

V

B

N

M

SPACE

,

.

ZERO

FEED

NOTE: Blank keys have no function.

Programming Keyboard Function

Name of Key

Function

 

 

 

 

 

 

 

1. Clears numeric data just entered.

 

CLEAR

 

 

 

2. Releases the scale from the error mode.

 

 

 

 

 

 

 

 

 

 

Selects the upper case or lower case.

 

SHIFT

 

 

 

 

 

 

 

 

 

 

 

Calls the PLU # which follows the PLU # currently called.

 

SET

 

 

 

Sets the media transparency on the sensor.

 

NEXT

 

 

 

 

Calls the PLU # registered right after currently called PLU #.

 

NEXT

 

 

PLU

 

 

 

 

 

Sets “AUTO CODE”.

 

AUTO

 

 

 

 

 

CODE

 

 

 

 

 

Changes the PLU # currently called.

 

CHANGE

 

 

PLU

 

 

 

 

 

 

 

 

 

Deletes PLU.

 

DELETE

 

 

 

 

 

PLU

 

 

 

 

 

Prints data set in the currently called PLU.

 

TEST

 

 

 

 

 

 

 

 

 

 

 

Inputs data to the H-9000 system during programming.

 

ENTER

 

 

 

 

 

 

 

 

5- 1

Image 12
Contents 9000N-US Page Safety Summary Precautions Table of Contents Issuing Labels with NET Weight Statement ・・・・・・・・・・・・・・ Programmed Data Verification Reports ・・・・・・・・・・・・・・・・・・・・・・Introduction Accessories Applicable Model∙ H-9000-N-US Description of the model number is as follows Specification PrinterOption LONSTLAN-2P TmccAppearance DisplayKEY Layout Programming KeyboardProgramming Keyboard Function Space SendProg Operation Keyboard and Speed Keyboard Operation Keyboard FunctionPLU PRT ForDT/TM VoidSelf Service Keyboard ZeroKEY Layout Procedure Before Operation Speed KEY SETRemoval and Replacement of Media Removal and Replacement of Media Power Outline of OperationRegistration mode XNOT Available1/4LB KEY 100g, kg KEY LB/kg KEY Tmcc CMT-port communicarion Clerk LabelProgramming Procedures How to access the Programming MenuTitle and Contents of Programming Menu How to enter characters TEC StorePLU Data Edit MenuPLU Data Setting For the UPC#Auto Code Ingredient Message Nutrition Setting When entering PLU#, be careful of the following Daily Value Max digits Contents of Daily value Set the Daily Value TableMemory file is sorted when a memory full error occurs Deleting Nutrition DataMemory file sort PLU Verifying Label Menu Item No Verifies PLU data stored in the scaleAddress and Commercial Message Setting Combination Message Message construction Message display timeScrolling Flashing Curtaining Scrolling up Scrolling down Thank YOUThank YOU Call Thank YOU ANK YOU Call AGASpecial Information Grade LineSpeed KEY Setting Setting Department/Vendor NumberDepartment Number Vendor NumberPrint Format By pressing KeyLabel Format Number Table Format NoDATE/TIME Setting Menu Item NoCMT Operations Error code during PL-3 operation Number of the data disc by using the rotary switchPL-3 Operation Program the fileTransmission Item List Item #CMT Transmission Delay Time Table IN-LINE/LOCALLON System Cancel Retry Data TransmissionPrice Initial #0 #19Default Bar Code Format BAR Code Format① Weigh or Fix Price Format ② By Count FormatFlag PLU # UPC # PC/D Price Weight PLU # UPC # PC/DTitles Transferring Logo Data Verify H-9000=CMTIdiom Setting Error message during data transmissionVendor Setting Free Format Setting Key functionsEnter SP-INFO/NET WT Logo Frequent Shopper Print coordinate How to access Report menu Programmed Data Verification ReportsMenu Set the zone PLU #. Ex. PLU #100 ~108 Password Security Setting Password and Protect MenuR S R S X Z× ー × Calling Menu by Entering Password Operating Procedures How to access REG., M.DOWN, or Rewrap menuMenu REG., M.DOWN, or Rewrap Mode Weigh Weighing OperationFIX Price Operation By Count Operation REG. MANU. BY-COUNT DonutsFor Print Count Operation To check the remaining number, clear the PLU and press KeyExample B When operating in Fix or By Count mode Set the number of labels. Max labels Enter the PLU # Issuing Labels with NET Weight Statement PLUSample label 12-10 TARE/SAVE Function Procedures PlatterCalling and Printing Grade Lines Calling and Printing Logos LogoMenu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by Count Selecting Print ItemDate Change Batch Print Mode with 30 Items Run Assignment Unit Price Change and G.Line/LOGO Call Label Issue Stop or Cancel Visual Commodity Library Dpt #Floating Vendor Price deletion SubtotalHow to access Read or Reset menu Total OperationHourly Total Report Grand Total ReportPLU Total Report Ex. Report MenuVendor Total Report For Enter PLU TotalError Message Table Programming ModeLabel lssue Mode Report and Reset ModeLON System Mode Cleaning the Print Head Troubleshooting Before You Call for ServicePage