9.PROGRAMMING PROCEDURES

9.2 PLU DATA SETTING

9.2PLU DATA SETTING

Menu Page: 1

Item No.: 1

Setting or changing the contents of PLU (PLU#, UPC#, Commodity Name, etc).

b

<MENU>

Page 1

SET

NEXT

Enter PLU# (max. 6 dig.)

1

AUTO

Set auto code

 

Is status

1

Set tare limit.

 

ENTER

of initial set

 

Max. 2 lb

ENTER

CODE

for the UPC#

 

 

 

#8-2?

 

 

 

 

 

 

 

 

0

 

 

 

NEXT

or

 

 

 

 

 

 

 

PLU

 

 

 

 

 

 

 

 

ENTER

Enter UPC#

ENTER

Enter commodity name.

 

ENTER

 

(Max. 6 dig.)

(max. 32 chars.×4 lines)

 

 

 

 

 

 

 

BY COUNT

Is status

1

 

 

 

 

 

In what mode

of initial set

 

 

 

 

is PLU used?

#1-6?

 

 

 

 

 

 

 

0

 

 

WEIGH

 

 

 

 

 

 

 

 

or FIX

 

Enter quantity for that price. (Max. 2 dig.)

ENTER

Enter unit price.

(max. 4 dig.)

ENTER

Is status

1

of initial set

#26-4?

0

Enter flag of

unit price.

(Refer to NOTE4)

ENTER

Enter shelf life.

(Max. 3 dig.)

ENTER

Is status

1

of initial set

#7-8?

0

Enter PERIOD OF

RELISH (Max. 3 dig.)

ENTER

Is status

1

of initial set

#23-1?

0

Enter tare wignt.

(Max. 2lb)

ENTER

2

Is status

 

of initial set

 

 

#8-1?

Select

 

0 or 1

compulsory tare

 

Is status

1

of initial set

#1-5?

0

Selection Mode Flag

0:Weight

1:By Count

2:Fix Price

ENTER

Is status

1

Safe Handing

Instruction

of initial set

 

 

0: Non Print

#10-5?

 

 

1: Print

 

 

0

 

 

ENTER

Status

1

of initial set

28-4?

See

0NOTE 7.

CHANGE

Enter current

 

 

Enter new

PLU

PLU#

 

ENTER

 

PLU#

ENTER

DELETE

Enter

ENTER

 

Y

or

N

PLU

PLU#

 

 

 

 

 

 

TEST

The setting label is issued.

 

 

(Sorting)

 

 

 

 

 

 

 

 

 

 

Y

b

 

 

 

 

 

 

PROG.

<MENU>

 

 

 

Any key

 

 

 

 

 

 

 

 

 

Page 1

 

 

 

except

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ESC.

Main

 

 

 

(Not Sorting)

 

 

 

 

 

 

 

 

 

The memory file is sorted when a

<MENU>

 

 

 

memory full error occurs.

 

 

 

 

Set tare %

 

 

ENTER

(Max. 99.9%)

 

 

 

 

 

(Price %)

 

 

 

 

Is status

2

Enter discount price

 

or rate.

 

of initial set

 

ENTER

 

(Price: Max. 5 digit

#12-4?

 

 

Rate: Max. 3 digit)

 

 

 

 

0 or 1

 

 

Is status

1

Enter LOGO #.

 

of initial set

 

(#0 - 26)

ENTER

#9-4?

 

or (#0-99)*

 

0

 

 

 

9- 5

*: Selectable by the initial setting #10-7.

Image 27
Contents 9000N-US Page Safety Summary Precautions Table of Contents Programmed Data Verification Reports ・・・・・・・・・・・・・・・・・・・・・・ Issuing Labels with NET Weight Statement ・・・・・・・・・・・・・・Introduction Accessories Applicable Model∙ H-9000-N-US Description of the model number is as follows Printer SpecificationTmcc OptionLON STLAN-2PDisplay AppearanceKEY Layout Programming KeyboardProgramming Keyboard Function Space SendProg Operation Keyboard and Speed Keyboard Operation Keyboard FunctionPLU Void PRTFor DT/TMZero Self Service KeyboardKEY Layout Speed KEY SET Procedure Before OperationRemoval and Replacement of Media Removal and Replacement of Media Outline of Operation PowerTmcc CMT-port communicarion Clerk Label Registration modeXNOT Available 1/4LB KEY 100g, kg KEY LB/kg KEYHow to access the Programming Menu Programming ProceduresTitle and Contents of Programming Menu TEC Store How to enter charactersMenu PLU Data EditFor the UPC# PLU Data SettingAuto Code Ingredient Message Nutrition Setting When entering PLU#, be careful of the following Set the Daily Value Table Daily Value Max digits Contents of Daily valueMemory file is sorted when a memory full error occurs Deleting Nutrition DataMemory file sort Menu Item No Verifies PLU data stored in the scale PLU Verifying LabelAddress and Commercial Message Setting Message construction Message display time Combination MessageThank YOU ANK YOU Call AGA Scrolling Flashing Curtaining Scrolling up Scrolling downThank YOU Thank YOU CallGrade Line Special InformationVendor Number Speed KEY SettingSetting Department/Vendor Number Department NumberBy pressing Key Print FormatFormat No Label Format Number TableDATE/TIME Setting Menu Item NoCMT Operations Program the file Error code during PL-3 operationNumber of the data disc by using the rotary switch PL-3 OperationTransmission Item List Item #CMT IN-LINE/LOCAL Transmission Delay Time TableLON System Initial #0 #19 Cancel RetryData Transmission Price② By Count Format Default Bar Code FormatBAR Code Format ① Weigh or Fix Price FormatPLU # UPC # PC/D Flag PLU # UPC # PC/D Price WeightTitles Verify H-9000=CMT Transferring Logo DataError message during data transmission Idiom SettingVendor Setting Free Format Setting Key functionsEnter SP-INFO/NET WT Logo Frequent Shopper Print coordinate How to access Report menu Programmed Data Verification ReportsMenu Set the zone PLU #. Ex. PLU #100 ~108 R S X Z Password SecuritySetting Password and Protect Menu R S× ー × Calling Menu by Entering Password How to access REG., M.DOWN, or Rewrap menu Operating ProceduresWeighing Operation Menu REG., M.DOWN, or Rewrap Mode WeighFIX Price Operation REG. MANU. BY-COUNT Donuts By Count OperationFor To check the remaining number, clear the PLU and press Key Print Count OperationExample B When operating in Fix or By Count mode Set the number of labels. Max labels Enter the PLU # PLU Issuing Labels with NET Weight StatementSample label 12-10 Platter TARE/SAVE Function ProceduresCalling and Printing Grade Lines Logo Calling and Printing LogosSelecting Print Item Menu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by CountDate Change Batch Print Mode with 30 Items Run Assignment Unit Price Change and G.Line/LOGO Call Label Issue Stop or Cancel Dpt # Visual Commodity LibraryFloating Vendor Subtotal Price deletionTotal Operation How to access Read or Reset menuEx. Report Menu Hourly Total ReportGrand Total Report PLU Total ReportFor Enter PLU Total Vendor Total ReportProgramming Mode Error Message TableReport and Reset Mode Label lssue ModeLON System Mode Cleaning the Print Head Before You Call for Service TroubleshootingPage