Toshiba EO1-32004BE, H-9000N-US owner manual Specification, Printer

Page 9

2.SPECIFICATION

2.1 PRINTER

2. SPECIFICATION

2.1 PRINTER

Item

Description

 

 

Unit Price Presettable

$ 0.01 - 99.99

Minimum Price Display

$ 0.01

Power Requirement

AC 120 V±10%, 60 Hz

Power Consumption

66 W, 1.1 A (Standby: 26 W, 0.39 A)

Temperature Limits

32°F- 104°F (0- 40)

Relative Humidity

35 % - 85 % (No condensation)

Message Display

256 x 64 dots Fluorescent display

Unit Price

4 digits

Total Price

5 digits

Capacity of PLU Memory

3600 PLUs max. (Standard)

Print Head

Thermal Print Head (2 inch wide)

Media Issue Method

On-demand

Dot Density

193 dots/inch (7.6 dots/mm)

Print Speed

3 inch/sec. (76.2 mm/sec.)

Available Print Width

2 inch (50.7 mm)

Recommended Media

 

Thermal Label

VHTS, VLTB (OSP)/Outer diameter: φ 90 mm (Max.)

Variable Length Label

VHTS, VLTB (OSP)/Outer diameter: φ 90 mm (Max.)

Thermal Receipt

FC (RICHO)/Outer diameter: φ 90 mm (Max.)

Interface

CMT/PL-3 interface (Program Loader)

 

LON interface (RS-485)

 

PC-AT KEY interface (Option)

 

TMCC interface (Option)

 

Drawer interface

 

LAN Interface (10 Base T) (Option)

Dimensions (approx.)

11.7 inch (width) x 11.6 inch (depth) x 14.6 inch (height)

 

298 mm (width) x 295 mm (depth) x 372 mm (height)

Weight

9 kg

 

 

Optional Scale Unit

 

(OP-9000N-30M-US)

 

Maximum Capacity

30 lb (17 Kg)

Minimum Scale Division

0.005 lb (0 - 15 lb.)

 

0.001 lb (15 - 30 lb.)

Display Range

0 - 30.05 lb

Weight Display digit

5 digits

Maximum Tare

2.000 lb

 

 

2- 1

Image 9
Contents 9000N-US Page Safety Summary Precautions Table of Contents Programmed Data Verification Reports ・・・・・・・・・・・・・・・・・・・・・・ Issuing Labels with NET Weight Statement ・・・・・・・・・・・・・・Introduction Accessories Applicable Model∙ H-9000-N-US Description of the model number is as follows Printer SpecificationLON OptionSTLAN-2P TmccDisplay AppearanceKEY Layout Programming KeyboardProgramming Keyboard Function Space SendProg Operation Keyboard and Speed Keyboard Operation Keyboard FunctionPLU For PRTDT/TM VoidZero Self Service KeyboardKEY Layout Speed KEY SET Procedure Before OperationRemoval and Replacement of Media Removal and Replacement of Media Outline of Operation PowerXNOT Available Registration mode1/4LB KEY 100g, kg KEY LB/kg KEY Tmcc CMT-port communicarion Clerk LabelHow to access the Programming Menu Programming ProceduresTitle and Contents of Programming Menu TEC Store How to enter charactersMenu PLU Data EditFor the UPC# PLU Data SettingAuto Code Ingredient Message Nutrition Setting When entering PLU#, be careful of the following Set the Daily Value Table Daily Value Max digits Contents of Daily valueMemory file is sorted when a memory full error occurs Deleting Nutrition DataMemory file sort Menu Item No Verifies PLU data stored in the scale PLU Verifying LabelAddress and Commercial Message Setting Message construction Message display time Combination MessageThank YOU Scrolling Flashing Curtaining Scrolling up Scrolling downThank YOU Call Thank YOU ANK YOU Call AGAGrade Line Special InformationSetting Department/Vendor Number Speed KEY SettingDepartment Number Vendor NumberBy pressing Key Print FormatFormat No Label Format Number TableDATE/TIME Setting Menu Item NoCMT Operations Number of the data disc by using the rotary switch Error code during PL-3 operationPL-3 Operation Program the fileTransmission Item List Item #CMT IN-LINE/LOCAL Transmission Delay Time TableLON System Data Transmission Cancel RetryPrice Initial #0 #19BAR Code Format Default Bar Code Format① Weigh or Fix Price Format ② By Count FormatPLU # UPC # PC/D Flag PLU # UPC # PC/D Price WeightTitles Verify H-9000=CMT Transferring Logo DataError message during data transmission Idiom SettingVendor Setting Free Format Setting Key functionsEnter SP-INFO/NET WT Logo Frequent Shopper Print coordinate How to access Report menu Programmed Data Verification ReportsMenu Set the zone PLU #. Ex. PLU #100 ~108 Setting Password and Protect Menu Password SecurityR S R S X Z× ー × Calling Menu by Entering Password How to access REG., M.DOWN, or Rewrap menu Operating ProceduresWeighing Operation Menu REG., M.DOWN, or Rewrap Mode WeighFIX Price Operation REG. MANU. BY-COUNT Donuts By Count OperationFor To check the remaining number, clear the PLU and press Key Print Count OperationExample B When operating in Fix or By Count mode Set the number of labels. Max labels Enter the PLU # PLU Issuing Labels with NET Weight StatementSample label 12-10 Platter TARE/SAVE Function ProceduresCalling and Printing Grade Lines Logo Calling and Printing LogosSelecting Print Item Menu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by CountDate Change Batch Print Mode with 30 Items Run Assignment Unit Price Change and G.Line/LOGO Call Label Issue Stop or Cancel Dpt # Visual Commodity LibraryFloating Vendor Subtotal Price deletionTotal Operation How to access Read or Reset menuGrand Total Report Hourly Total ReportPLU Total Report Ex. Report MenuFor Enter PLU Total Vendor Total ReportProgramming Mode Error Message TableReport and Reset Mode Label lssue ModeLON System Mode Cleaning the Print Head Before You Call for Service TroubleshootingPage