Toshiba G9000 operation manual Recommended Cable Sizes

Page 59

TABLE 3.4 Recommended Cable Sizes

kVA

Input

Output

Input Side

 

Output Side

Bypass Side

DC Input Side

Cable

 

Torque

Cable

Torque

Cable

Torque

Cable

Torque

Capacity

Voltage

Voltage

Size

 

ft. lbs

Size

ft. lbs

Size

ft. lbs

Size

ft. lbs

 

 

 

 

 

 

 

 

 

 

 

 

80kVA

480V

480V

1 AWG –

 

17-22

1 AWG –

17-22

1 AWG –

17-22

3/0 AWG –

17-22

1/0 AWG

 

ft. lbs

1/0 AWG

ft. lbs

1/0 AWG

ft. lbs

4/0 AWG

ft. lbs

 

 

 

 

100kVA

480V

480V

2/0 AWG –

 

17-22

2/0 AWG –

17-22

2/0 AWG –

17-22

(2) x 1 AWG –

17-22

3/0 AWG

 

ft. lbs

3/0 AWG

ft. lbs

3/0 AWG

ft. lbs

(2) x 2/0 AWG

ft. lbs

 

 

 

 

160kVA

480V

480V

250 MCM –

 

17-22

250 MCM –

17-22

250 MCM –

17-22

(2) x 3/0 AWG –

17-22

300 MCM

 

ft. lbs

300 MCM

ft. lbs

300 MCM

ft. lbs

(2) x 250 MCM

ft. lbs

 

 

 

 

225kVA

480V

480V

500 MCM –

 

17-22

500 MCM –

17-22

500 MCM –

17-22

(2) x 350 MCM –

17-22

(2) x 250 MCM

 

ft. lbs

(2) x 250 MCM

ft. lbs

(2) x 250 MCM

ft. lbs

(2) x 400 MCM

ft. lbs

 

 

 

 

300kVA

480V

480V

(2) x 250 MCM –

 

29-39

(2) x 250 MCM –

29-39

(2) x 250 MCM –

29-39

(3) x 300 MCM –

29-39

(2) x 300 MCM

 

ft. lbs

(2) x 300 MCM

ft. lbs

(2) x 300 MCM

ft. lbs

(3) x 350 MCM

ft. lbs

 

 

 

 

500kVA

480V

480V

(3) x 300 MCM –

 

29-39

(3) x 300 MCM –

29-39

(3) x 300 MCM –

29-39

(4) x 500 MCM –

29-39

(3) x 350 MCM

 

ft. lbs

(3) x 350 MCM

ft. lbs

(3) x 350 MCM

ft. lbs

(5) x 300 MCM

ft. lbs

 

 

 

 

750kVA

480V

480V

(4) x 350 MCM –

 

29-39

(4) x 350 MCM –

29-39

(4) x 350 MCM –

29-39

(6) x 400 MCM –

29-39

(5) x 250 MCM

 

ft. lbs

(5) x 250 MCM

ft. lbs

(5) x 250 MCM

ft. lbs

(6) x 500 MCM

ft. lbs

 

 

 

 

*1 – The cables must be selected to be equal to the sizes listed in the table.

*2 – Voltage drop across power cables not to exceed 2% of nominal source voltage.

*3 – Allowable ampere-capacities based on 75 °C insulated copper conductor at ambient temperature of 30 °C. *4 – All wiring to be in accordance with all applicable national and/or local electrical codes.

G9000 Installation and Operation Manual

49

Image 59
Contents Document 4GBA0012 Rev. E January Page Document No GBA0012 Rev. E January Page Important Notice Uninterruptible Power SystemPurpose and Scope of Manual Table of Contents List of Tables List of Figures Power wire connections parallel system configuration How to use this Manual Important Safety Instructions Safety Precautions Environment standard UPS Installation EnvironmentCapacity kVA Bypass Voltage Vac Bypass Rating Aac Breaker a General Definitions Operation Overview CB3 Mccb Single Line Diagram Battery Operation Page 1 UPS Parts Location 80,100kVA UPS cabinet Front Inside View UPS cabinet Front ViewUPS Parts Location 300kVA Door Backside Main Cabinet Backside of Left Door 4 UPS Parts Location 500kVA UPS cabinet Front ViewItem 10 Grounding bar is not shown in .4.5. Refer to Figure 12. SW5 13. SW6 Reset switch Button Test switchCN96 CN95 CN94 1 Parallel I/F PCB IFAU-08 80-225kVALCD Touch Panel Monitor Display External I/F PCB IOAU-09 Figure Signal I/F on IOAU-09 boardDescription of Figures 1.4.1-5 to AC input, AC output, DC input terminal 15 L S/W switch for Service Personnel onlyExternal contact signal terminal block Refer to Figures 3.7.1 to 3.7.4 for details80kVA / 72kW 480V SpecificationsLbs Heating KVA Knockout KBTU/h Width Depth Height Net Weight TypicalWidth Depth Height Gross Weight Lbs KVA UPSAC Input A Detail of SpecificationsCooling Operating TemperaturePhase I 80-225kVA Phase II 300-750kVA Output Capacity of Equipment Number Application Rating of Contactors, Breakers and FusesOperator Controls and Indicators Load on inverter Load on Inverter green Battery operation Battery OP. orangeEPO Button Emergency Power Off button LED DisplayStartup/Shutdown Guidance Figures 2.3.1 to Liquid Crystal DisplayMenu 2 Startup guidance 2 Output values 1 Log menu Fault Indication Input Power FailureMessage TN2 External Signal Terminal BlockSummary Alarm Triggers on fault alarm only OUT8 Total Alarm Triggers on any alarm including faultsTN1 Battery Breaker PanelTerminals 3 to 4 Load on Bypass contact OUT1 Output Contacts for external alarm annunciationTerminals 7 to 8 Battery Operation contact OUT3 Terminals 11 to 12 Battery Low Voltage contact OUT512 Remote Start Contact Connections Input Contacts for remote access of UPSTerminals 9 to 10 Remote Inverter Stop input terminal IN2 Terminals 11 to 12 Battery Temp. High contact input IN3Terminals 13 to 14 Power Demand Command contact input IN4 Used to perform a remote UPS Emergency Power Off EPORemotEyeII Introduction 13.1 Configuration of the RemotEyeII Overview 80-225kVAPSAU-60 Back of the front door Main cabinet RemotEyeIIDPAU-81 SW1 Cable2 Cable3 ProvidedSW1 Back of the front left door Main cabinetProvided PSAU-60 PS1 Cable1 Cable1 3BBA0083P001 Male Cable3 12V Power Cable Cable2 Sub 9-pin Cable15 PSAU-60 PCB PS1 Connector Definition Figure Space requirement for routine maintenance Transportation and InstallationTransportation Installation Installation ProcedureKVA Rating Current Permitted a External Battery SupplyProcedure for Cable Connections UPS Capacity DC VoltageRequired Page Recommended Cable Sizes UPS Terminal Designation Crimp Type Compression LugInput A40,B40,C40 Location of bus bars and terminal blocks Bottom EntryUPS module UPS module 300kVA Detailed Power TerminalsUPS module 500kVA A50, B50, C50 Grounding Bar not shown 18.5UPS module 750kVA AC Output 78.7 A50, B50, C50 Grounding Bar Not shown 19.7BUS BAR Detail TOP View BUS BAR Detail TOP View BUS BAR Connection TOP View Alternate Landing Main Cabinet BUS BAR Connection DC Breaker for Battery Breaker 52Ln *1 AC output CB2 BatteryBypass52S Converter CB1 /Charger Inverter 52C UPS-1 UPS-1 ~~~~~ UPS-1 No.N UPS Use Ethernet STP Shielded Twisted Pair Cable Cat 5 or ~~~~~ Circuit protectors location Operating ProceduresOperation Menu Shut-down ProcedureUPS Bypass Operation ProcedureLCD Screen MMS Operation MMS Start-up ProcedureResponse to UPS Failure UPS Component Parts BatteryReplace battery if its capacity is within this percentage Fault Codes Failure Code List Fault Code CB2 Open DC Unbalanced Overvoltage Engineer Inverter Call Service 52S Abnormal Daily Inspection How to perform daily inspectionPage Variations Consult latest edition of applicableNational and local codes for possible 94 @ 0.9 PF 235 250 AT Kcmil 300 kcmil 27.6 x 32.8 x 855 136 13,463114 150 AT 3/0 100 120 150 AT 3/0149 @ 0.9 PF 372 400 AT Kcmil 35.4 x 32.8 x 1160 144 17,821151 181 250 AT Kcmil 300 kcmil 160 192 250 AT Kcmil 300 kcmil210 @ 0.9 PF 524 600 AT 300 kcmil 2 x 400 kcmil 35.4 x 32.8 x 1230 152 25,060212 255 350 AT Kcmil 2 x 250 kcmil 225 271 350 AT Kcmil 2 x 250 kcmil309 @ 1.0 PF 772 800 AT 400 kcmil 51.2 x 32.7 x 1230 189 31,659312 376 500 AT 250 kcmil 2 x 300 kcmil 300 361 500 AT 4/0 2 x 250 kcmil512 @ 1.0 PF 1292 1400 AT 400 kcmil 4 x 500 kcmil 70.9 x 32.7 x 3300 205 52.8 23.6 42.3521 626 800 AT 300 kcmil 3 x 350 kcmil 500 601 800 AT 300 kcmil 3 x 350 kcmil776 @ 1.0 PF 1935 2000 AT 400 kcmil 6 x 500 kcmil 90.6 x 32.7 x 4255 207 79,147781 939 1400 a 500 kcmil 750 902 1200 a X350 kcmil 4 x 400 kcmilPage Page Industrial Division
Related manuals
Manual 17 pages 22.24 Kb