2. ” or ENTER is the Enter button.

(a)Press and hold the Enter button for at least 2 seconds to read the parameter settings of the UPS. Press the Enter button again to cycle through each successive parameter.

(b)Ten seconds of inactivity will return the display to the original status.

3. ” or FUNC is the Function button.

(a)Press and hold the Function button for at least 2 seconds to access the selectable parameters. Press the Function button again to cycle through each successive selectable parameter.

(b)Press the Enter button to view or change the displayed parameter.

(c)Ten seconds of inactivity will return the display to the original status.

4.STATUS (2400/6000VA Only) will display the UPS data.

(a)Press and hold the Status button for at least 2 seconds to read the parameter settings of the UPS. Press the Enter button again to cycle through each successive parameter.

(b)Ten seconds of inactivity will return the display to the original status.

5.ESCAPE (2400/6000VA Only) – Press Escape to return to the main display immediately.

7.3Control Panel Functions

The front panel is composed of five LED indicators, an LCD screen, and a speaker for audible alarms.

Rack-mounted units have international symbols stenciled next to the LED indicators

instead of text.

 

 

ON/OFF or

 

— is on when the UPS is turned on (green).

 

ON-LINE or

 

— is on when in the Normal or Static Bypass modes. Also

 

 

indicates that there is voltage at the output terminals (green).

ON-BAT or

 

— is on while operating in the Battery mode.

BYPASS or

 

— is on while operating in the Bypass mode (yellow).

 

22

Image 47
Contents 1000 &1000+ Series Important Notice Uninterruptible Power System Table of Contents Limitations and Exclusions Manual’s Purpose and Scope Page VII ICES-003 EMC StatementsFCC Part Declaration of Conformity Request Safety Alert Symbol / Signal Words General Safety InstructionsPage Special Symbols Important Safety Instructions Qualified Personnel shall Qualified Personnel onlyPage XVI LA Sécurité Conserver CES Instructions Instructions Importantes ConcernantInspection/Storage/Disposal Disposal Storage MaintenanceInstallation Precautions Conductor Routing and Grounding Operating Precautions Maintenance Note Xxiv System Description IntroductionGeneral Description Efficiency Optimizer Function Auto-Restart Free Run ModeDiagnostic Tests System Configuration Shipping StoragePage UPS Frequency Converter Option InstallationEnvironment 2000VA 3000VA Tower Rear Panel Rear Panel Views 1000VA 1500VA Tower Rear Panel2400VA Tower Rear Panel X1-N or N-X3 120V Half Load 2400VA Power Wiring Options2000 3000 VA Rack mount 2U Rear Panel 1000 1500 VA Rack mount 2U Rear PanelVA Rack mount UPS 3U, Battery Pack 3U Rear Panel 2400 VA Example of Installation of Plug & Play products6000 VA HE Mode SET ON/OFF Front Panel SettingsOutlet GROUP1/GROUP2 RS-232 Standard Interface Port Computer and Alarm ConnectionsDry Contact Interface optional card DB9 Male Connector Outline Facing connectorLoad Segments EPO Port emergency power offUSB Port Network Transient ProtectorButton Operation User’s Guide to OperationsUPS Startup and Shutdown Starting the UPS Shutting Down the UPSControl Panel Functions Normal Display Control panels 1000/1500/2000/3000VALCD Message Description UPS ConfigurationsUPS Meters Display Page Interpreting UPS Messages Audible AlarmsSilencing an Alarm UPS Manual TestAlarm Description What You Should Do TroubleshootingBattery Servicing MaintenancePower Range 1000-3000 VA 120 Technical SpecificationsPower Range 2400 VA 208/240 Rackmount US 208/240V UT1G1G060C6RKB3 + UT1-BR-0607 General Power Range 6000 VA 208/240Environment RKB2 Power Range 1000-3000 VA 230Backup Time at Partial Loads Uninterruptible Power System Warranty InformationLimitations and Exclusions Modifications