Toshiba 1000 user manual Power Range 2400 VA 208/240

Page 55

9.2Power Range 2400 VA (208/240 V)

Tower

US 208/240 Model

UT1G2L024C6T

Input

Voltage

208 or 240 VAC (161 – 276 V)

 

Voltage Range

+15% to -34%

 

Frequency

50 / 60 Hz auto sensing

 

Power Factor

Greater than 0.97

 

Topology

True on-line Double conversion Input PF correction

Output

Voltage

120/208/240 VAC

 

Capacity (VA)

2400 VA

 

Capacity (W)

1920 W

 

Frequency

50 / 60 (45-65) Hz auto sensing *

 

Wave Form

Sine wave, zero transfer time

 

Load Power Factor

0.8

 

Efficiency

Greater than 87%

 

AC/DC/AC

 

 

Rated Current

10 A @ 240V

 

Overload Capacity

125% for 1 min 130% for 10 sec

 

Crest Factor

3.0 at full load

Battery

DC Voltage

72V / 12 V (9 AH x 6)

 

Backup Time

11 min (full load)

 

Interface

RS-232 and USB standard RemotEye II® and EMD option

Physical

Dimensions

23.2”L x 10.1”W x 27.6”H

 

Weight

154.3 lbs

 

Line Cord

None (Hardwired)

 

Receptacles

None (Hardwired)

Environmen

Operating

32 – 104°F (0 – 40°C)

t

Temperature

 

 

Altitude

3300 ft (1000 m) above sea level

Warranty

 

Three years on electronics

 

 

Two years full replacement on battery (See Toshiba warranty policy for

 

 

full details.)

Output frequency can hard set at 50 or 60 Hz by installing an optional software upgrade. This upgrade enables the user to select a fixed output frequency and simultaneously disables the bypass mode.

Standards – FCC Part 15 Class A (2-3kVA), UL 1778, ICES-0003

Safety – EN 62040-1, Emissions: EN 62040-2, Immunity: EN 62040-2 Category C2

30

Image 55
Contents 1000 &1000+ Series Important Notice Uninterruptible Power System Table of Contents Limitations and Exclusions Manual’s Purpose and Scope Page VII FCC Part EMC StatementsICES-003 Declaration of Conformity Request Safety Alert Symbol / Signal Words General Safety InstructionsPage Special Symbols Important Safety Instructions Qualified Personnel shall Qualified Personnel onlyPage XVI LA Sécurité Conserver CES Instructions Instructions Importantes ConcernantInspection/Storage/Disposal Disposal Storage MaintenanceInstallation Precautions Conductor Routing and Grounding Operating Precautions Maintenance Note Xxiv System Description IntroductionGeneral Description Efficiency Optimizer Function Diagnostic Tests Free Run ModeAuto-Restart System Configuration Shipping StoragePage Environment InstallationUPS Frequency Converter Option 2000VA 3000VA Tower Rear Panel Rear Panel Views 1000VA 1500VA Tower Rear Panel2400VA Tower Rear Panel X1-N or N-X3 120V Half Load 2400VA Power Wiring Options2000 3000 VA Rack mount 2U Rear Panel 1000 1500 VA Rack mount 2U Rear PanelVA Rack mount UPS 3U, Battery Pack 3U Rear Panel 2400 VA Example of Installation of Plug & Play products6000 VA HE Mode SET ON/OFF Front Panel SettingsOutlet GROUP1/GROUP2 RS-232 Standard Interface Port Computer and Alarm ConnectionsDry Contact Interface optional card DB9 Male Connector Outline Facing connectorLoad Segments EPO Port emergency power offUSB Port Network Transient ProtectorButton Operation User’s Guide to OperationsUPS Startup and Shutdown Starting the UPS Shutting Down the UPSControl Panel Functions Normal Display Control panels 1000/1500/2000/3000VAUPS Meters Display UPS ConfigurationsLCD Message Description Page Interpreting UPS Messages Audible AlarmsSilencing an Alarm UPS Manual TestAlarm Description What You Should Do TroubleshootingBattery Servicing MaintenancePower Range 1000-3000 VA 120 Technical SpecificationsPower Range 2400 VA 208/240 Rackmount US 208/240V UT1G1G060C6RKB3 + UT1-BR-0607 General Power Range 6000 VA 208/240Environment RKB2 Power Range 1000-3000 VA 230Backup Time at Partial Loads Uninterruptible Power System Warranty InformationLimitations and Exclusions Modifications