Liebert 700VA, GXT3 Features, Available Models, Product Description, UPS models, power ratings

Page 10

Product Description

1.0PRODUCT DESCRIPTION

The Liebert GXT3 is a compact, online uninterruptible power system (UPS) that continuously conditions and regulates its output voltage. The Liebert GXT3 is designed to supply microcomputers and other sensitive electronic equipment with clean sine wave input power, 700VA to 3000VA at 230V.

Upon generation, AC power is clean and stable. However, during transmission and distribution it is subject to voltage sags, spikes and complete failure that may interrupt computer operations, cause data loss and damage equipment.

The Liebert GXT3 protects equipment from these disturbances. The Liebert GXT3 continuously charges its batteries from the mains, enabling it to supply power to connected loads, even when the mains fail.

This section describes the UPS, its features, models, appearance and components, operating principles and operating mode.

1.1Features

The UPS includes the following features:

Intelligent battery management to extend the battery life

Operation and display panel with LED for monitoring load percentage and battery capacity independently

Flexible network management with Liebert MultiLink® software

Fan fault self-inspection and automated diagnostic function

Intelligent fan operation, automatically changing rotation speed depending on system requirements, to decrease power consumption and noise

Input circuit breaker to ease recovery from overloads

CE mark and safety approval from CE

Communication options: USB port, Liebert IntelliSlot® port and terminal block communication

Dry contacts for remote monitoring

Input power factor greater than 0.99

Output voltage selection function

1.2Available Models

Available models of the UPS are shown in Table 1:

Table 1

UPS models, power ratings

 

 

Model

Nominal Power Rating

 

 

GXT3-700RT230

700VA/630W

 

 

GXT3-1000RT230

1000VA/900W

 

 

GXT3-1500RT230

1500VA/1350W

 

 

GXT3-2000RT230

2000VA/1800W

 

 

GXT3-3000RT230

3000VA/2700W

 

 

 

Liebert® GXT3

4

Image 10
Contents Liebert GXT3 UPS 230V 700VA-3000VA Page Table of Contents Operation MaintenanceTroubleshooting CommunicationFigures Page Important Safety Precautions UPS Safety NotesBattery Safety Information for the Protection of the EnvironmentGlossary of Symbols Model Nominal Power Rating FeaturesUPS models, power ratings Available ModelsAppearance Rear Panel FeaturesAppearance and Components Ventilation Slots Operation and Display PanelOperating principle diagram Major ComponentsOperating Mode Battery Recharge Mode Manual Bypass ModeBattery Mode Frequency Converter ModeUnpacking and Inspection Preparation for InstallationInstallation What’s IncludedConnectors Spacers Support Bases Mechanical InstallationTower Installation Front Plastic Bezel CoverOperation and Display Panel Rotated Clockwise 90 Degrees Liebert GXT3 UPSRack Installation Pulling inner member from each bracket assemblyInstalling rear member of each bracket assembly Installing inner members Specification of input circuit breaker Connecting to AC Mains and LoadsConnecting Battery Cables Cable ConnectionConnecting Communication Cables Connecting USB Communication CablesOperation and Display Panel 1 On/Alarm Silence/Manual Battery Test buttonControl Buttons Standby/Manual Bypass buttonLevel Indicators Battery Level Indicators IndicatorsLoad Level Indicators UPS status indicators UPS Status IndicatorsUPS Status Indicator Icon Color Description Starting the UPS Startup Checklist for the Liebert GXT3Manual Battery Test Manual BypassDisconnecting Input Power from the Liebert GXT3 Shut Down the Liebert GXT3Communication Liebert IntelliSlot Communication CardsLiebert MultiLink USB Port Communication Configuration ProgramOutput voltage option, all models Any Mode Shutdown Terminal Block CommunicationOn Battery Battery Mode ShutdownLow Battery Battery Replacement Procedures Replacing the Internal Battery PackMaintenance Replacement battery pack model numbersBattery Connector Battery ChargingInternal Battery Pack Handle Pull Out with Battery Handle Checking UPS Status PrecautionsChecking UPS Functions Indicators UPS SymptomsTroubleshooting Indicator Diagnosis/Audible alarmTroubleshooting table Audible AlarmAudible alarm description Condition AlarmEmerson representative or Emerson Channel Support Battery Cabinet Input Breaker External Battery ConnectorSpecifications Specifications of GXT3-700RT230 and GXT3-1000RT230 UPSBattery run time Recharge Time See TableBattery cabinet specifications Operating temperature parametersBattery run times CabinetProduct Warranty Registration Twor k Ne tIs t Care
Related manuals
Manual 13 pages 59.68 Kb