Liebert 700VA, GXT3, 3000VA user manual UPS Status Indicators, UPS status indicators

Page 25

Operation and Display Panel

3.2.2UPS Status Indicators

UPS status is indicated by five symbols: fault indicator, AC input indicator, battery indicator, inverter indicator and bypass indicator. Table 5 shows the symbols and their meanings.

Table 5 UPS status indicators

UPS Status

 

 

 

 

 

Indicator

 

Icon

Color

Description

 

 

 

 

 

 

Fault Indicator

 

 

 

Red

On if the UPS has detected a fault; Off if there is no fault

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC input Indicator

 

 

 

Green

On when the mains input power is normal; Off during mains

 

 

 

 

 

 

failure; flashing when mains power is outside specifications

 

 

 

 

 

 

 

 

 

 

 

Battery Indicator

 

 

 

Amber

On when the battery is supplying power; Off when the battery

 

 

 

 

 

 

is not supplying power

 

 

 

 

 

 

 

 

 

 

 

Inverter Indicator

 

 

 

Green

On when the inverter is supplying power; Off when the

 

 

 

 

 

 

inverter is not supplying power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On when the bypass is supplying power; Off when the bypass

 

 

 

 

 

Bypass Indicator

 

 

 

Amber

is not supplying power; flashing when mains power is outside

 

 

 

 

 

specifications

 

 

 

 

 

 

19

Liebert® GXT3

Image 25
Contents Liebert GXT3 UPS 230V 700VA-3000VA Page Table of Contents Troubleshooting MaintenanceOperation CommunicationFigures Page UPS Safety Notes Important Safety PrecautionsInformation for the Protection of the Environment Battery SafetyGlossary of Symbols UPS models, power ratings FeaturesModel Nominal Power Rating Available ModelsAppearance and Components Rear Panel FeaturesAppearance Ventilation Slots Operation and Display PanelMajor Components Operating principle diagramOperating Mode Battery Mode Manual Bypass ModeBattery Recharge Mode Frequency Converter ModeInstallation Preparation for InstallationUnpacking and Inspection What’s IncludedTower Installation Mechanical InstallationConnectors Spacers Support Bases Front Plastic Bezel CoverLiebert GXT3 UPS Operation and Display Panel Rotated Clockwise 90 DegreesPulling inner member from each bracket assembly Rack InstallationInstalling rear member of each bracket assembly Installing inner members Connecting Battery Cables Connecting to AC Mains and LoadsSpecification of input circuit breaker Cable ConnectionConnecting USB Communication Cables Connecting Communication CablesControl Buttons 1 On/Alarm Silence/Manual Battery Test buttonOperation and Display Panel Standby/Manual Bypass buttonLevel Indicators Battery Level Indicators IndicatorsLoad Level Indicators UPS status indicators UPS Status IndicatorsUPS Status Indicator Icon Color Description Manual Battery Test Startup Checklist for the Liebert GXT3Starting the UPS Manual BypassShut Down the Liebert GXT3 Disconnecting Input Power from the Liebert GXT3Communication Liebert IntelliSlot Communication CardsLiebert MultiLink USB Port Communication Configuration ProgramOutput voltage option, all models Terminal Block Communication Any Mode ShutdownOn Battery Battery Mode ShutdownLow Battery Maintenance Replacing the Internal Battery PackBattery Replacement Procedures Replacement battery pack model numbersBattery Connector Battery ChargingInternal Battery Pack Handle Pull Out with Battery Handle Checking UPS Status PrecautionsChecking UPS Functions Troubleshooting UPS SymptomsIndicators Indicator Diagnosis/Audible alarmAudible alarm description Audible AlarmTroubleshooting table Condition AlarmEmerson representative or Emerson Channel Support Input Breaker External Battery Connector Battery CabinetSpecifications of GXT3-700RT230 and GXT3-1000RT230 UPS SpecificationsSee Table Battery run time Recharge TimeOperating temperature parameters Battery cabinet specificationsCabinet Battery run timesProduct Warranty Registration Is t Ne tTwor k Care