IMPORTANT SAFETY PRECAUTIONS

! WARNING

Observe all cautions and warnings in this manual. Failure to do so may result in serious injury or death.

Refer all UPS and battery service to properly trained and qualified service personnel. Do not attempt to service this product yourself.

Opening or removing the cover may expose you to lethal voltages within this unit even when it is apparently not operating and the input wiring is disconnected from the electrical source.

Never work alone.

SAVE THESE INSTRUCTIONS

This manual contains important safety instructions that must be followed during the installation and maintenance of the UPS and batteries. Read this manual thoroughly before attempting to install or operate this UPS.

UPS Safety Notes

The UPS contains no user-serviceable parts except the internal battery pack. Do not remove the cover. Removing the cover may result in electric shock and will invalidate any implied warranty.

The UPS has an internal battery, so the output receptacles of the UPS may carry live voltage even if the UPS is not connected to mains input power.

Before moving or rewiring the UPS, disconnect mains input power and the battery and make sure that the UPS is completely shut down. Otherwise, the output terminal may carry live voltage, presenting an electric shock hazard.

To ensure human safety and normal UPS operation, the UPS must be properly grounded before use.

When the UPS is connected to an IT power distribution system, the short-circuit protection device must be installed on the neutral line.

Install and use the UPS in the following environments:

Temperature: 0°C to 40°C (32 - 104°F); relative humidity: 0% to 95%, non-condensing)

Out of direct sunlight

Away from heat source

Stable surface, not subject to vibrations or shocks

Away from dust and other particulates

Away from corrosive substances, salts and flammable gases

Keep the air inlet and outlet of the UPS unobstructed. Poor ventilation will increase the UPS internal temperature and can shorten the life of the UPS and its batteries.

Keep liquid and other foreign objects away from the UPS.

In case of fire, use a dry chemical fire extinguisher to put out the fire. Using a fluid fire extinguisher may cause electric shock.

This UPS is not intended for use with life support and other designated critical devices. Maximum load must not exceed that shown on the UPS rating label. This UPS is designed for data processing equipment. If uncertain, consult your local dealer or Emerson Network Power® representative.

1

Liebert® GXT3

Image 7
Contents Liebert GXT3 UPS 230V 700VA-3000VA Page Table of Contents Communication MaintenanceTroubleshooting OperationFigures Page UPS Safety Notes Important Safety PrecautionsInformation for the Protection of the Environment Battery SafetyGlossary of Symbols Available Models FeaturesUPS models, power ratings Model Nominal Power RatingVentilation Slots Operation and Display Panel Rear Panel FeaturesAppearance and Components AppearanceMajor Components Operating principle diagramOperating Mode Frequency Converter Mode Manual Bypass ModeBattery Mode Battery Recharge ModeWhat’s Included Preparation for InstallationInstallation Unpacking and InspectionFront Plastic Bezel Cover Mechanical InstallationTower Installation Connectors Spacers Support BasesLiebert GXT3 UPS Operation and Display Panel Rotated Clockwise 90 DegreesPulling inner member from each bracket assembly Rack InstallationInstalling rear member of each bracket assembly Installing inner members Cable Connection Connecting to AC Mains and LoadsConnecting Battery Cables Specification of input circuit breakerConnecting USB Communication Cables Connecting Communication CablesStandby/Manual Bypass button 1 On/Alarm Silence/Manual Battery Test buttonControl Buttons Operation and Display PanelLevel Indicators Battery Level Indicators IndicatorsLoad Level Indicators UPS status indicators UPS Status IndicatorsUPS Status Indicator Icon Color Description Manual Bypass Startup Checklist for the Liebert GXT3Manual Battery Test Starting the UPSShut Down the Liebert GXT3 Disconnecting Input Power from the Liebert GXT3Communication Liebert IntelliSlot Communication CardsLiebert MultiLink USB Port Communication Configuration ProgramOutput voltage option, all models Terminal Block Communication Any Mode ShutdownOn Battery Battery Mode ShutdownLow Battery Replacement battery pack model numbers Replacing the Internal Battery PackMaintenance Battery Replacement ProceduresBattery Connector Battery ChargingInternal Battery Pack Handle Pull Out with Battery Handle Checking UPS Status PrecautionsChecking UPS Functions Indicator Diagnosis/Audible alarm UPS SymptomsTroubleshooting IndicatorsCondition Alarm Audible AlarmAudible alarm description Troubleshooting tableEmerson representative or Emerson Channel Support Input Breaker External Battery Connector Battery CabinetSpecifications of GXT3-700RT230 and GXT3-1000RT230 UPS SpecificationsSee Table Battery run time Recharge TimeOperating temperature parameters Battery cabinet specificationsCabinet Battery run timesProduct Warranty Registration Care Ne tIs t Twor k