Troubleshooting
Problem | Cause | |
|
| |
COVER warning | The filter cover is not correctly attached. | |
indicator lights up. |
| |
The lamp cover is not correctly attached. | ||
| ||
|
| |
|
| |
LAMP warning | Lamp running time has exceeded 2000 | |
indicator lights up or | hours. | |
blinks. |
| |
The lamp has burned out. | ||
| ||
|
| |
|
| |
TEMP warning indicator | The temperature inside the | |
lights up. | extremely high. | |
|
| |
|
| |
FAN warning indicator | The fan is broken. | |
lights up. |
| |
|
|
Remedy
Tightly attach the filter cover.
Tightly attach the lamp cover.
Replace the lamp with a new one.
Replace the lamp with a new one.
Check that the ventilation slots are not covered.
Contact the store where the
•This unit uses a DMDTM chip for the picture display. Their highly accurate technology makes it possible to keep more than 99.99% of effective pixels, however, unexpectedly it can produce less than 0.01% of ineffective pixels. In such a case, missing or flashing of a few pixels can be found on the screen. These are characteristics of DMDTM , not mechanical problems.