3.Change of the lubrication method and notes
Details of change and supplement
A procedure and precautions applicable to the products affected by the change were added to “(2) Lubrication method” on
(1)Lubrication method of products affected by the change
1)Set the robot to the posture shown in Fig.
2)Refer to the "5.3.2Installing/removing the cover" on page 44 and remove the covers.
3)Insert the grease shown in Table
4)Replace the covers with the removal procedure in reverse.
(2)Precautions for lubrication
Take note of the following points when lubricating all products, regardless of whether or not they are affected by the change.
CAUTION | Use manual grease gun, and inject grease with pressure 0.03Mpa or less. Do not |
use the grease gun, which derived by the factory air presser to | |
| avoid injecting by too high pressure. |