Agilent Technologies manual Connecting Multiple 82357As. An Agilent 82357A USB/GPIB

Page 22

Installing the 82357A

Step 4: Configuring the 82357A

installation sequence has completed, an Agilent 82357A USB/GPIB Interface Detected dialog box should appear.

3If the Agilent 82357A USB/GPIB Interface Detected dialog box does not appear, and the Connection Expert utility is not running, STOP. See Chapter 3 - Troubleshooting the 82357A before continuing.

NOTE

Connecting Multiple 82357As. An Agilent 82357A USB/GPIB

Detected dialog box should appear each time you plug an 82357A into

a USB port. For example, if you plug three 82357As into USB ports, three dialog boxes should appear. Each dialog box will remain until you remove it by clicking OK (or the x box). These dialog boxes will only appear if Connection Expert is not running.

4Record VISA/SICL Names. For future programming use, you will need to know the VISA Interface Name (also called VISA interface ID) and SICL Interface Name (also called SICL interface ID) as shown on the dialog box. You may want to record these values now. In Connection Expert, you can see these interface IDs displayed in the detail pane

22

Chapter 1

Image 22
Contents USB/GPIB Interface Converter Page Contents Guide Contents Guide General Information Installing the 82357A Installing the 82357A Steps to Install the 82357A Before You Install the 82357ABefore You Install the 82357A Check Your ShipmentCheck System Requirements Installing Agilent IO Libraries Suite Checking for Installed Agilent IO LibrariesInstalling Agilent IO Libraries Suite ‰ Click Start Run Connecting the 82357A 82357A Hardware DescriptionConnecting the 82357A to Your PC Connecting the 82357A to a USB Hub USB Cable 82357A Sequence Windows XP Only Observing Windows Plug and Play ManagerIntroduction Hardware Installation dialog box appears Typical Windows Plug and Play Manager Sequence Connecting the 82357A Connecting the 82357A Configuring the 82357A Setting 82357A Default ConfigurationConnecting Multiple 82357As. An Agilent 82357A USB/GPIB Configuring the 82357A Setting 82357A Custom Configuration Configuring the 82357A Connection Expert Connecting Gpib Instruments Connecting a Single Gpib InstrumentConnecting Multiple Gpib Instruments Programming via the 82357A Establishing Instrument CommunicationProgramming Gpib Instruments Introduction to IO Accessing Visa Sicl ManualsConfiguration InterfaceTypical System Installation 82357 USB/GPIB Interface Using the 82357A Using the 82357A Modes of Operation Initial 82357A Operating StatesSingle Mode Features Multiple Mode Features Introduction to 82357A Operating ModesSingle 82357A Operation Multiple 82357A Operation SRQ OperationSetting Configuration Parameters Changing Configuration ParametersSetting Timeout Floor Values Changing Modes of OperationIntroduction Setting T1 Value With Visa Setting 82357A High-Performance OperationSetting T1 Value With Sicl Setting Configuration Parameters Chapter Troubleshooting the 82357A Troubleshooting the 82357A Troubleshooting Flowchart Observe the LED StatesFor telephone and web assistance, see Contacting Agilent on Hardware Checks Reboot the PCCheck USB Cables, USB Interface, Host PC Check Device Manager Verify Agilent IO Libraries Suite Installation Software Installation ChecksCheck Suspend/Resume Operation Software Installation Checks Verify 82357A USB Driver Installation \Windows\inf\agt3579x.infSoftware Configuration Checks Checking IO Control OperationCheck USB Scanner Check for usbscan.sys Windows 98 SE Only Assigning usbscan Driver to the 82357A 82357A Service Information Service/Support InformationContacting Agilent 82357A User’s Guide Information 82357A User’s Guide Information Guide Contents Guide General Information Government Restricted RightsPrinting History Warranty InformationTrademark Information Copyright InformationDeclaration of Conformity 82357A Specifications 82357A Specifications Technical Specifications General RequirementsSupplementary Information Gpib Modes Operation SupportedIndex IndexIndex Page 82357-90002