Troubleshooting the 82357A

Software Installation Checks

Software Installation Checks

When only the red FAIL LED is still ON after 10 seconds, the 82357A has been detected by the host computer, but has not yet been configured for use with the Agilent IO Libraries. Possible causes for this is that the appropriate version of the Agilent IO Libraries or Agilent IO Libraries Suite has not been installed on your PC or the 82357A USB drivers have not been installed.

Check Suspend/Resume Operation

Some Windows operating systems support Power Management which can suspend the PC while the 82357A is in operation. After a Suspend/Resume cycle, the 82357A may not properly resume operation. In this case, you may need to unplug/replug the USB cable to restore 82357A operation. If this does not correct the problem, go to “Verify Agilent IO Libraries Suite Installation”.

NOTE

If your 82357A applications must not be preempted by a PC Suspend event, we recommend you disable Power Management on your PC by using the Control Panel Power Options dialog.

Verify Agilent IO Libraries Suite Installation

When only the red LED is ON after 10 seconds and all Windows Plug and Play Manager activity has ceased, start your troubleshooting sequence by verifying IO Libraries installation. If any action taken results in a change in the LED status, go to “Software Configuration Checks” or to “Hardware Checks”.

1Check Agilent IO Libraries Version. If a version of the Agilent IO Libraries or IO Libraries Suite has been installed, a blue IO icon is normally displayed on the Windows taskbar (on the lower right-hand side of the screen).

IO Libraries Icon

IO Libraries Suite Icon

Chapter 3

49

Image 49
Contents USB/GPIB Interface Converter Page Contents Guide Contents Guide General Information Installing the 82357A Installing the 82357A Before You Install the 82357A Steps to Install the 82357ACheck Your Shipment Before You Install the 82357ACheck System Requirements Checking for Installed Agilent IO Libraries Installing Agilent IO Libraries SuiteInstalling Agilent IO Libraries Suite ‰ Click Start Run 82357A Hardware Description Connecting the 82357AConnecting the 82357A to Your PC Connecting the 82357A to a USB Hub USB Cable 82357A Sequence Windows XP Only Observing Windows Plug and Play ManagerIntroduction Typical Windows Plug and Play Manager Sequence Hardware Installation dialog box appearsConnecting the 82357A Connecting the 82357A Setting 82357A Default Configuration Configuring the 82357AConnecting Multiple 82357As. An Agilent 82357A USB/GPIB Configuring the 82357A Setting 82357A Custom Configuration Configuring the 82357A Connection Expert Connecting a Single Gpib Instrument Connecting Gpib InstrumentsConnecting Multiple Gpib Instruments Establishing Instrument Communication Programming via the 82357AProgramming Gpib Instruments Configuration Accessing Visa Sicl ManualsIntroduction to IO InterfaceTypical System Installation 82357 USB/GPIB Interface Using the 82357A Using the 82357A Initial 82357A Operating States Modes of OperationIntroduction to 82357A Operating Modes Single Mode Features Multiple Mode FeaturesSingle 82357A Operation SRQ Operation Multiple 82357A OperationChanging Configuration Parameters Setting Configuration ParametersChanging Modes of Operation Setting Timeout Floor ValuesIntroduction Setting T1 Value With Visa Setting 82357A High-Performance OperationSetting T1 Value With Sicl Setting Configuration Parameters Chapter Troubleshooting the 82357A Troubleshooting the 82357A Observe the LED States Troubleshooting FlowchartFor telephone and web assistance, see Contacting Agilent on Hardware Checks Reboot the PCCheck USB Cables, USB Interface, Host PC Check Device Manager Verify Agilent IO Libraries Suite Installation Software Installation ChecksCheck Suspend/Resume Operation Software Installation Checks \Windows\inf\agt3579x.inf Verify 82357A USB Driver InstallationChecking IO Control Operation Software Configuration ChecksCheck USB Scanner Check for usbscan.sys Windows 98 SE Only Assigning usbscan Driver to the 82357A 82357A Service Information Service/Support InformationContacting Agilent 82357A User’s Guide Information 82357A User’s Guide Information Guide Contents Government Restricted Rights Guide General InformationTrademark Information Warranty InformationPrinting History Copyright InformationDeclaration of Conformity 82357A Specifications 82357A Specifications General Requirements Technical SpecificationsGpib Modes Operation Supported Supplementary InformationIndex IndexIndex Page 82357-90002