Agilent Technologies 82357A manual Accessing Visa Sicl Manuals, Introduction to IO, Interface

Page 31

 

Installing the 82357A

 

Step 6: Programming via the 82357A

Accessing VISA and

You can access .pdf copies of the Agilent VISA User’s Guide and the

SICL Manuals

Agilent SICL User’s Guide for Windows from the blue IO icon on the

 

Windows taskbar. Adobe Reader is required to view these manuals.

 

To access the Agilent VISA User’s Guide, click the IO icon and then click

 

Documentation VISA Users Guide. To access the Agilent SICL User’s Guide

 

for Windows, click the IO icon and then click Documentation SICL Users

 

Guide. To access VISA COM information, and function references for VISA,

 

VISA COM, and SICL, click the IO icon and then click Documentation IO

 

Libraries Suite Help.

Introduction to IO

An IO interface consists of a hardware interface and a software interface.

Interface

One purpose of the Connection Expert utility is to associate a unique

Configuration

software interface ID with a hardware interface.

 

The Agilent IO Libraries Suite uses an Interface ID or Logical Unit Number to

 

identify an interface. This information is passed in the parameter string of

 

the viOpen function call in a VISA program or in the iopen function call in

 

a SICL program.

 

Connection Expert assigns an Interface ID and Logical Unit (LU) Number to

 

the interface hardware, as well as other necessary configuration values for

 

an interface when the interface is configured. Typically, the LU Number is

 

automatically assigned and you can ignore its setting. The LU Number is

 

used internally as a unique identifier. When the IO interface is configured,

 

you can use Agilent VISA, VISA COM, or SICL to program assigned

 

instruments.

Example: IO

For example, the GPIB interface system in the following figure consists of

Interface

a Windows PC with an 82357A USB/GPIB Interface Converter connected

Configuration

between a USB port and three GPIB instruments with GPIB primary

 

addresses of 3, 4, and 5, respectively. The instruments are connected via

 

GPIB cables.

 

For this system, the Connection Expert utility has been used to assign a

 

VISA name of “GPIB1” and a SICL name of “hpib7”. With these names

 

assigned to the interfaces, the VISA/SICL addressing is as shown in the

 

figure.

 

Since unique names have been assigned by Connection Expert, you can

 

use the VISA viOpen command to open the IO paths to the GPIB

 

instruments as shown in the figure. Or, you can use the SICL iopen

 

command to open the IO paths.

Chapter 1

31

Image 31
Contents USB/GPIB Interface Converter Page Contents Guide Contents Guide General Information Installing the 82357A Installing the 82357A Before You Install the 82357A Steps to Install the 82357ACheck Your Shipment Before You Install the 82357ACheck System Requirements Checking for Installed Agilent IO Libraries Installing Agilent IO Libraries SuiteInstalling Agilent IO Libraries Suite ‰ Click Start Run 82357A Hardware Description Connecting the 82357AConnecting the 82357A to Your PC Connecting the 82357A to a USB Hub USB Cable 82357A Sequence Windows XP Only Observing Windows Plug and Play ManagerIntroduction Typical Windows Plug and Play Manager Sequence Hardware Installation dialog box appearsConnecting the 82357A Connecting the 82357A Setting 82357A Default Configuration Configuring the 82357AConnecting Multiple 82357As. An Agilent 82357A USB/GPIB Configuring the 82357A Setting 82357A Custom Configuration Configuring the 82357A Connection Expert Connecting a Single Gpib Instrument Connecting Gpib InstrumentsConnecting Multiple Gpib Instruments Establishing Instrument Communication Programming via the 82357AProgramming Gpib Instruments Interface Accessing Visa Sicl ManualsConfiguration Introduction to IOTypical System Installation 82357 USB/GPIB Interface Using the 82357A Using the 82357A Initial 82357A Operating States Modes of OperationIntroduction to 82357A Operating Modes Single Mode Features Multiple Mode FeaturesSingle 82357A Operation SRQ Operation Multiple 82357A OperationChanging Configuration Parameters Setting Configuration ParametersChanging Modes of Operation Setting Timeout Floor ValuesIntroduction Setting T1 Value With Visa Setting 82357A High-Performance OperationSetting T1 Value With Sicl Setting Configuration Parameters Chapter Troubleshooting the 82357A Troubleshooting the 82357A Observe the LED States Troubleshooting FlowchartFor telephone and web assistance, see Contacting Agilent on Hardware Checks Reboot the PCCheck USB Cables, USB Interface, Host PC Check Device Manager Verify Agilent IO Libraries Suite Installation Software Installation ChecksCheck Suspend/Resume Operation Software Installation Checks \Windows\inf\agt3579x.inf Verify 82357A USB Driver InstallationChecking IO Control Operation Software Configuration ChecksCheck USB Scanner Check for usbscan.sys Windows 98 SE Only Assigning usbscan Driver to the 82357A 82357A Service Information Service/Support InformationContacting Agilent 82357A User’s Guide Information 82357A User’s Guide Information Guide Contents Government Restricted Rights Guide General InformationCopyright Information Warranty InformationTrademark Information Printing HistoryDeclaration of Conformity 82357A Specifications 82357A Specifications General Requirements Technical SpecificationsGpib Modes Operation Supported Supplementary InformationIndex IndexIndex Page 82357-90002