Dell 124T LTO-3 Loader Task Error Types, Code Update Error Types, Scsi Server Task Error Types

Page 46

51

IP Stack Memory Allocation

Verify that the network is properly configured (i.e. no loop-back condition exists).

 

Error

 

 

 

 

Verify that the autoloader operates correctly when properly configured and attached directly to a host

52

IP Stack Can't Free Memory

 

system using a cross-over cable.

 

 

 

 

If all previous steps fail, contact support.dell.com.

53

Stack DTrap Occurred

 

 

 

 

 

 

Loader Task Error Types

 

 

 

 

 

 

60

Drive Init Failed

Check support.dell.com for PowerVault 124T firmware updates.

 

 

 

 

61

Drive Login Error

Check the TapeAlert log for more specific drive error information. Refer to Table 3 for recommended

 

 

 

 

62

Drive Logout/Unexpected Error

 

actions.

 

 

 

 

63

Drive Command Failed

Power cycle the autoloader using the front panel power button and retry the operation.

 

 

64

Drive Response Timeout

 

 

65

Command Flushed From Queue

If all previous steps fail, contact support.dell.com.

 

 

 

 

 

 

66

Drive Manager Not In Correct

 

 

 

State

 

 

67

Drive Reporting Not Ready

 

 

 

 

 

 

68

Autoclean Move Failed

Check the Remote Management Unit autoclean Configuration settings. Insure that a valid cleaning

 

 

 

cartridge is located at the configured location.

 

 

Verify that the cleaning cartridge does not have labels or other matter placed anywhere on the

 

 

 

cartridge except where labels are expected to be placed.

 

 

Try a different cleaning cartridge.

 

 

If the operation fails with two different cleaning cartridges, contact support.dell.com.

 

 

 

 

69

Drive Unload Retry

Check the TapeAlert log for more specific drive error information. Refer to Table 3 for recommended

 

 

 

actions..

 

 

Verify that the cleaning cartridge does not have labels or other matter placed anywhere on the

 

 

 

cartridge except where labels are expected to be placed.

 

 

Try to load a different piece of media.

 

 

Power cycle the autoloader using the front panel power button and retry the operation.

 

 

If all previous steps fail, contact support.dell.com.

 

 

 

 

6D

Drive Communications Error

Check support.dell.com for PowerVault 124T firmware updates.

 

 

Check the TapeAlert log for more specific drive error information. Refer to Table 3 for recommended

6E

Drive Communications Error

 

actions.

 

 

 

 

Power cycle the autoloader using the front panel power button and retry the operation.

 

 

 

 

6F

Loader Communication Error

If all previous steps fail, contact support.dell.com.

 

 

 

 

 

 

Code Update Error Types

 

 

 

 

 

 

70

Failed to Send CUP Cmd to

Verify the firmware images for both the autoloader and drive are the most recent images located at

 

Drive / No Response From Drive

 

support.dell.com.

 

 

 

 

71

CUP Send Failed

Review the firmware update readme file provided with the firmware images.

 

 

72

Drive Update Failed, Media

 

Note: The recommended method for drive firmware update is through the host SCSI interface using

 

Present

 

 

 

 

the DFU utility provided with the firmware images. The recommended method for loader firmware

73

Image Size in Header Too Big

 

 

update is through the Remote Management Unit.

74

Block Erase Failed

 

Verify all SCSI cable and terminator connections between the host and autoloader.

 

 

75

Flash Program Failed

 

 

 

 

 

Verify no media in drive during update.

76

Header Corrupt

 

 

 

 

77

Checksum Error

Power cycle the autoloader using the front panel power button and retry the operation.

 

 

78

Timeout During CUP

 

 

 

 

If all previous steps fail, contact support.dell.com.

79

Reset During Drive Update

 

 

 

 

 

 

7A

Unexpected Reset From Drive

 

 

 

 

 

 

7B

Unexpected Message From PSP

 

 

7C

Personality or Version Check

 

 

 

Failed

 

 

 

 

 

 

7D

SCSI Error During Write Buffer

 

 

 

Command

 

 

 

 

 

 

7E

Uncompressed EDC Failure

 

 

7F

Image Processing Ended Early

 

 

 

 

 

 

SCSI Server Task Error Types

 

 

 

 

 

 

80

Unexpected Response or Data

Verify the host backup application and device driver are at the latest supported revision at

 

Received

 

support.dell.com.

 

 

 

 

Image 46
Contents Dell PowerVault 124T LTO-3 Autoloader Users Guide Configuring the Autoloader Setting the Scsi ID Setting EthernetSetting the Subnet Mask Setting the IP AddressSetting an IP Gateway Setting the Snmp Server Setting the TimeSetting the Time Server Scsi Barcode Length Barcode ReaderEnter Setting Passwords Setting MagazinesSetting Security Getting Lost PasswordsBack to Contents Stopping a Diagnostic Test Diagnostic Tests from the Front PanelSetting the Security Front Panel Diagnostic TestsRemote Management Unit Diagnostic Tests Diagnostics Using the Remote Management UnitOnline Services Technical AssistanceAutoTech Service Ftp.dell.comAutomated Order-Status Service Technical Support ServiceBefore You Call Accessories Installation OverviewInstallation Preparation Scsi Bus RequirementsBar Code Reader Choosing a LocationUL Requirements Product OverviewIdentifying Product Components AccessoriesUnpacking the Autoloader Back Panel OverviewScsi cable Scsi terminator Power cable Connecting the Scsi and Power CablesEthernet cable Scsi cable Scsi terminator Preparing the Host and Verifying the Connection Installing the Device DriversClick Update Driver Tape Drive Device DriverAutoloader Device Driver Enabling LUN Support in Linux Back to Contents Overview Operators Panel Functionality Enter PasswordsLogout Insert a Single Cartridge Using CartridgesMoving a Single Cartridge Ejecting a Single Cartridge Using Magazines and Magazine BlanksInward Side of a Magazine Outward Side of a Magazine Ejecting a Magazine Installing a MagazineManually Operating the Magazine Viewing Status Information Viewing PowerVault 124T Autoloader StatusRunning an Inventory MagazinesViewing Tape Drive Status Viewing Firmware VersionViewing Element Status Viewing Tape Drive VersionIP address Viewing Ethernet InformationMAC address NetworkOpening the Remote Management Unit Default Username and PasswordRemote Management Unit Overview Viewing Status InformationFeedback on Pages ConfigurationTime Display System Operations OptionsCompression Cleaning TapeBar Code Reader Setting Network Options Setting the MagazinesSetting the System Time From the Configuration menu, click NetworkingTo set User Administration Setting Front Panel Security OptionsTo Set Network Configuration To set the Client Authorization ControlViewing Error or History Logs Error Logs and DiagnosticsFirmware Library Operations Set to Home Autoloader Environmental Specifications Physical SpecificationsAutoloader Performance Specifications Characteristic Product AloneAutoloader Shock Specifications Autoloader Power SpecificationsAutoloader Vibration Specifications Tape Drive SpecificationsProblem Probable Cause Suggested Action Basic TroubleshootingBefore Contacting Customer Support Operator Control Panel Error Display Checking for ErrorsAutoloader Logs through OCP Autoloader Error DetailAutoloader Logs Autoloader Logs through RMUSystem Shutdown/Disruption Error Types Message Error TypesStack/Global Data Corruption Error Types System Miscellaneous Error TypesMiscellaneous Error Types Tape Drive Error TypesDrive/Media Error Types TCP/IP Stack and Task Error TypesCode Update Error Types Loader Task Error TypesScsi Server Task Error Types Servo Elevator Hardware Error Types Picker/Magazine Servo Error TypesServo Picker Hardware Error Types Magazine Hardware Error Types Servo Motor Error TypesSystem Event Types Barcode Error Types Front Panel Error TypesDiagnostic Error Types TapeAlert Interpretation TapeAlert LogsTapeAlert Logs through OCP TapeAlert Logs through RMUPage Page Page To prepare the autoloader for shipment Returning the Autoloader for ServiceTo Remove the Autoloader from a Rack Packing the Autoloader