E9 | Time Update Event | The system time was changed. No action required. | ||
Front Panel Error Types |
|
| ||
|
|
| ||
EA | LCD Busy Error | Possible LCD controller problem, software error, or communication error. | ||
|
| • | Power cycle the autoloader. | |
|
| • | Run the Random Moves test. | |
EB | LCD Goto Error | |||
|
| |||
|
| • | If all previous steps fail, contact support.dell.com. | |
|
|
| ||
EC | Login/Password Error | Incorrect login from front panel. | ||
|
| • | Use correct login/password. | |
ED | Socket Error During SNTP | |||
|
| |||
|
|
|
| |
Barcode Error Types |
|
| ||
|
|
|
| |
F0 | Bar Code Init Error | • | Remove magazines and inspect cartridges. Verify that valid barcode labels are being used on all | |
|
|
| cartridges, and | |
|
|
|
| |
F1 | Bar Code Hardware Error | • | If barcode labels are not being used, disable the barcode reader through the Operator Control Panel | |
|
| |||
|
|
| or Remote Management Unit. | |
F2 | Bar Code Baud Rate Error |
| ||
|
| |||
|
| • | Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control | |
F3 | Bar Code Handshake Error |
| Panel (OCP). | |
|
| |||
|
|
| Note: The Random Moves test requires a minimum of two cartridges present within the autoloader. | |
F4 | Bad/Noisy Response From Bar |
|
| |
| Code Reader | • | If all previous steps fail, contact support.dell.com. | |
|
|
| ||
F5 | Checksum Failed | Incomplete barcode label or barcode checksum failed. | ||
|
| • | Repeat test with new cartridge or label. | |
|
| • | If problems recur with the original cartridge or label, replace. | |
|
| • | If all previous steps fail, contact support.dell.com. | |
|
|
| ||
F6 | Barcode No Read | Barcode label not present. | ||
|
| • | Apply valid barcode label to cartridge, or disable the barcode reader through the Operator Control | |
|
|
| Panel or Remote Management Unit. | |
|
|
|
| |
F7 | Barcode Mismatch Error | • | Power cycle the autoloader. | |
|
| • | Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control | |
|
|
| Panel (OCP). | |
|
|
| Note: The Random Moves test requires a minimum of two cartridges present within the autoloader. | |
|
| • | If all previous steps fail, contact support.dell.com. | |
|
|
| ||
F8 | Barcode Duplicate Label Error | Duplicate barcode. | ||
|
|
|
| |
Diagnostic Error Types |
|
| ||
|
|
|
| |
F9 | Diagnostic Test Failure | • | Power cycle the autoloader. | |
|
| • | ||
|
| • | If all previous steps fail, contact support.dell.com. | |
|
|
|
| |
FA | Diagnostic Error, Drive | • | Verify that valid, not data protected media is present for test. | |
| Reporting Write Protect |
|
| |
|
| • | Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control | |
|
|
| Panel (OCP). | |
|
|
| Note: The Random Moves test requires a minimum of two cartridges present within the autoloader. | |
FB | Diagnostic Error, Cleaning Tape |
| ||
| Inserted |
|
| |
|
| • | If all previous steps fail, contact support.dell.com. | |
|
|
| ||
FC | Diagnostic Load Tape Prompt | This is a prompt to manually load a cartridge as required for test. | ||
|
|
|
| |
FD | Diagnostic Unknown Tape | • | Verify that valid, not data protected media is present for test. | |
| Format |
|
| |
|
| • | Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control | |
|
|
| Panel (OCP). | |
|
|
| Note: The Random Moves test requires a minimum of two cartridges present within the autoloader. | |
|
| • | If all previous steps fail, contact support.dell.com. | |
|
|
| ||
FE | Diagnostic Invalid Configuration | This is an indication that a minimum of two pieces of media are required for test. | ||
|
| • | Insure at least two cartridges are present in the autoloader and |