Caution and care

HEAVY OBJECTS SHOULD NEVER BE PLACED ON THE UNIT (E.G., TV)

NEVER TOUCH OR INSERT ANY OBJECT INSIDE THE UNIT

Touching the inside of the cabinet or inserting foreign objects of any kind not only creates a safety hazard but can also cause extensive damage.

PROTECT THE POWER CORD

Damage to the power cord may cause fire or shock hazard. If the mains cord is damaged, switch off the mains outlet and carefully unplug the cord by holding the mains plug.

UNPLUG THE POWER CORD DURING A LONG ABSENCE

Turn off the power and unplug the power cord during a long absence.

MAINTAIN GOOD VENTILATION

Do not obstruct the many ventilation holes on the unit. For maximum ventilation, leave some space around the unit and place the unit on a hard level surface only, and ensure it is not covered during use. Heavy objects should never be placed on the unit.

WHEN NOT IN USE

When not in use always turn OFF the unit's POWER.

CABINET CARE

Never use petroleum-based cleaners. Clean with a soft cloth moistened with soap and water and wipe dry. PVC cables or leads should not be left in contact with the cabinet surface for long periods.

ATTACHING THE FERRITE CORE

The ferrite core is essential to avoid radio interference from the cables connected the unit against peripheral device. Be sure to attach the ferrite core to all cables connected to ALARM IN terminals (GND terminals) and I/O terminals.

INSTALLATION LOCATION

For excellent performance and lasting reliability install in a location that is:-

1.Well ventilated, out of direct sunlight and away from direct heat.

2.A solid vibration-free surface.

3.Free from high humidity, excessive dust and away from magnetic fields.

4.Please ensure that the ventilation fan located on the unit’s back panel is not blocked.

UNSUITABLE LOCATIONS

Placing the unit in the following places might shorten the product life:

Extremely cold places, such as refrigerated warehouses and ice houses

Places where excessive hydrogen sulfide is likely to be generated, such as hot-springs areas

Places or locations with salt air environment.

WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. THIS APPARATUS MUST BE GROUNDED.

MAINS LEAD CONNECTION

The mains lead on this Unit is fitted with a non-rewireable mains plug, incorporating a 5A fuse. If you need to replace the fuse, use a 5A fuse approved by BSI or ASTA to BS 1362, ensuring you refit the fuse cover. If the mains plug is not suitable for the sockets in your home, and you require to remove the plug, remove the fuse, cut off the plug then dispose of the plug immediately, to avoid a possible electric shock hazard. To refit a new plug, follow these instructions; Green-and-yellow: Earth, Blue: Neutral and Brown: Live.

As the colours in the mains lead of this Unit may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows.

•The wire which is coloured green-and-yellow must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol È or coloured green or green-and-yellow.

•The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black. •The wire which is coloured blown must be connected to the terminal which is marked with the letter L or coloured red.

This Unit complies with the requirements of the EC Directive 89/336/EEC, “EMC Directive” , as amended by Directive 93/68/EEC. The requirements for the susceptibility according to EN 55024 and the requirements for interference according to EN 55022 are observed for the operation on residential areas, business, light industrial premises and in small scale enterprises, inside as well as outside of the building. All places of operation are characterised by their connection to the public low voltage power supply system. This unit is manufactured in accordance with EN 60950.

There may be cases when the unit’s built-in MOTION DETECTION function does not operate properly due to external condition or video input signal or other factors.

The user will not be indemnified for problems (e.g., recording failure or playback failure) that occur with either the unit or a connected device during operation. It is recommended that backups of important recordings are made regularly as a precaution against possible breakdowns and accidents.

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Beginning

ENGLISH

3

Image 3
Contents DX-TL1600EM Features Unplug the Power Cord During a Long Absence Contents Communication settings Major operations and their functions Play button Play Device indicatorsPlay Mode buttons Play Device buttonMajor operations and their functions Terminals Exiting the menu How to use JOG dial and Shuttle ringSetting the character size Basic OperationsCamera mark will be shown on the present time dis- play Setting the present timeDaylight saving Present time displayBasic Operations Multiplexer functionsBasic recording Check the estimated recording time Setting the maximum recording fieldsPress the SET UP button to exit settings Example Choose Select REC Mode B the default setting is aSetting the define group Press the REC buttonPress the Stop button to stop recording Ton on the front of the unit Basic playbackBasic searching function Time date searchMAN Set the start time and end time of copying manually Press the Search button to clear the Time Date Search menuDisplay will return to the present time display Language selection settingYou can copy the data even during Recording Turn the Shuttle ring to the right to start copyingConnections Turning ON/OFF this Unit by peripheral sourceAttaching the ferrite core Peripheral devices to be connected Alarm Recording ConnectionConnecting with peripheral recording devices Connection when using several peripheral recording devicesConfirming the connected device Initial settingsHow to install an external hard disk drive Example Installing a 9GB hard disk drive to ID1Press the Power button again Setting this unit to delay the boot up timeMenu functions Main MenuSUB Menu Operations From **-**-** ****** to Menu functionsSetting character size How to set up / Various settingsHow to display menus Setting Display ModeVarious settings Be changed as follows Capacity remain settingCall OUT setting None No signal is emitted from the Call OUT terminalResetting the Archive Pointer Service menu settingBuzzer setting Power Failure listInitializing menus IM-CHECK Mode settingHDD repeat recording Initial set upClock setting Archive medium overwrite settingInitial SET UP menu will be displayed Auto-eject settingExample Setting Auto Eject to OFF the default is on Archive Data settingMotion Detection setting Backing up a data block containing the alarm recordBacking up a small alarm record FIFO/OVERWRITE Mode settingShowing the recorded period Information menuElapsed time display Values they will remain 2STurn the Shuttle ring twice to the right Quick settingRDD Menu Data Loading setting Menu Data Saving RDD setting CommandsMaximum recording fields setting Various recording settingsVarious recording settings Image quality settingWill be changed as follows Various recording settingsWhen the is assigned, the camera is disabled Changed as followsGround the Alarm in terminal Tection setting in the Initial SET UP menu is onCamera Alarm Rec setting Pre-alarm recording settingMotion menu will appear DET settingCH. motion detection setting Selection camera noSetting the detection mask Sensitivity settingTurn the Shuttle ring to the left to finish setting Test Mode menu will appear Motion threshold settingTest mode setting To finish setting, turn the Shuttle ring to the leftIng the SPLIT/SEQUENCE button How to use the Zoom buttonAge will appear pixelized when enlarged Multiplexer functionsHow to use the camera number buttons Multiplexer functionsSPLIT/SEQUENCE button Multiplexer display Screen SW Pattern settingsSplit 4 Screen setting Split 9 Screen settingImage quality of split screen Please change settingsSplit 16 Screen setting Sequence settingSelected pattern will start flashing Camera title settingDisplaying the title Maximum of 30 seconds can be setRepeat Steps 4 and 5 to input Exit Alarm display settingOperation examples Operation example 1 Simultaneous Backup using the TimerExample of a system using the following peripherals Record settings are made as followsOperation example Making backups as neededOperation examples Operation example 2 Endless Repeat recordingSettings for Motion Detection Setting are made as follows Settings for Timer Program are made as followsComplete the program setting Using the TimerSetting the Timer Timer Setting screenEstimating recording when using the Timer Press the Timer REC buttonTo set other programs, repeat steps 5 through Medium of the peripheral device Using the TimerOverlapping Timer settings DET Application settingAlarm Recording Using the Timer / Alarm RecordingPlease refer to Basic recording on page 12 for details Pre-alarm RecordingVarious recordings Repeat RecordingSeries Recording Series Recording menu settings for both unitsDisplay the Initial SET UP menu Flashing will move to capacity settingVarious playback functions Time date search Monitor display settings and playback operationVarious playback functions / Various search High-speed fast-forward/high-speed rewindSkip Search Alarm List SearchHow to count index signals Various searchCopying from the hard disk to the copying device Various search / Using peripheral devices / Making copiesJump to Start point oldest recording Scsi ID number allocationRestoring items from the archive device to the hard disk Setting of Copy rangeMaking copies Restoring items onto the hard disk from the copying deviceCancelling Copy operation Making copies / Making backupsBackup operation Procedure for settingIndividual settings during Backup operation Making backupsPower failure time display Making backups / Other convenient functionsTimer Backup Power failure reset recordingOther convenient functions Power failure compensation circuitPassword Lock function Example Changing passwordsConnecting with a personal computer Communication settings / Connecting to a personal computerRS-232C settings TCP / IP settingsCommand code and status Connecting to a personal computer / Command codesCommand codes Commands Functions Status, when normal executeDetails of the numbers Initial Setup Service Power Failure Rear Terminal Normal REC SettingTime Date Adjust Communication SettingSmall 1 Large FS1 Split Screen SettingCF? SA?Selected Pattern 1 ~ SKP Skip PWR Power ARC Archive AEJ EjectSPLIT4 AC?Superior QR? DW?PP? Basic Standard MediumStandard Medium Power 3 RemainAS1 AS0Remain AlarmprotFS2 RearArchive Device HDD RESTORE, OverwriteDevice RJ?HDD Near END Backup Near OvertakeBackup System Error RC***AOMain Devicehdd Others~ 1 0 PWR-OFF 1 CONFIG/INITIALIZE Status code Meaning of status Table of Error CodeError code Meaning of error Table of Status CodeCharacter Search Character Search commandsCommands Functions Status,when normal execute Character SearchSample operation Character SearchRecording duration is set to Medium Pre-alarm recording time tableRecording time table Recording duration is set to LongDevice does not respond TroubleshootingIs the Lock indicator light on? Operate Copying device/archiveGlossary Troubleshooting / GlossaryIs peripheral device’s Scsi ID setting set correctly? Check the Access indicator19,20 Canceling27,28 60-6310kΩ5V Input22kΩ terminal 047∝F Specifications872C273B5