Hitachi CMP307XU manual When you disconnect the power plug, Do not put things on the monitor

Page 7

Caution

Electric shock or other accidents may cause serious injury or damage to

your property.

 

You must to check the user manual of the computer when you connect to the monitor.

The weight of the monitor or obstructing the ventilation hole of the computer equipment may cause distortion or damage of the computer equipment.

Disconnect the power plug from the power point when you carry the monitor.

Carrying the monitor without disconnecting the power plug from the power point may damage the cord and cause a fire or electric shock. You are advised to carry the monitor with two persons. Handle with care when you carry the monitor, particularly take care of glass screen.

When you disconnect the power plug.

You have to grasp the power plug itself, do not pull the power cord.

If you pull the power cord, you may damage it and it may cause a fire or electric shock.

Do not touch the power plug just after disconnecting it from the power point or you may receive an electric shock.

Disconnect the power plug from the power point when you don't use the monitor for a long time.

This is just for your safety.

Do not put the monitor in atmosphere with soot, steam, high humidity, and dust.

It may cause a fire or electric shock.

Do not put the monitor in high temperature atmosphere.

Do not put the monitor in the place exposed to the direct rays of the sun or inside car under the burning sun for a long period of time. Heat may cause a fire, transformation, or melting of the monitor.

Do not put things on the monitor.

Do not put things on the monitor or give some shock to the monitor.

The monitor may fall down or drop from a desk. And it may cause injury.

Caution

You may have serious injury or your property may be damaged unless

you follow the instruction below.

 

Do not bundle the power cord.

It will be heated up or it may cause a fire.

Caution for 200 - 240V operation only

This equipment relies on the protective devices in the building installation for short - circuit and over - current protection. Refer to the following table for the suitable number and location of the protective devices which should be provided in the building installation.

INFORMATIVE EXAMPLES OF PROTECTIVE DEVICES IN SINGLE - PHASE

EQUIPMENT OR SUB - ASSEMBLIES

 

 

Protection

Minimum number

 

 

 

of fuses or circuit -

Location

 

 

against

breaker poles

 

 

 

 

 

 

 

 

 

 

Case A:

Equipment to be connected to POWER SYSTEMS

Earth faults

1

Phase conductor

 

with earthed neutral reliably identified, except for

 

 

 

 

Overcurrent

1

Either of the two conductors

 

Case C below.

Case B:

Equipment to be connected to any supply, including IT

Earth faults

2

Both conductors

 

POWER SYSTEMS and supplies with reversible plugs,

 

 

 

 

Overcurrent

1

Either of the two conductors

 

except for Case C below.

Case C: Equipment to be connected to 3 - wire power

Earth faults

2

Each phase conductor

 

systems with earthed neutral reliably identified.

Overcurrent

2

Each phase conductor

 

 

 

 

 

 

 

Verify that the protective devices in the building installation meets the conditions in the table prior to installing the equipment.

ENGLISH

Remove the power cord for complete isolation!

For complete isolation from the power source, remove the power cord from the monitor or from the wall socket.

5

Image 7
Contents Plasma Inch High Definition Plasma Display Large-screen, high-definition plasma display panel FeaturesContents Safety Guidelines Do not touch the power plug when lightning is close to you Do not damage or modify the power cordEnclosed power cord must be used Be careful of power cord connectionRemove the power cord for complete isolation When you disconnect the power plugDo not put the monitor in high temperature atmosphere Do not bundle the power cordFCC Federal Communications Commission Statement Warning PrecautionsInstallation Instructions Component Names Installation InstructionsRear Monitor rear panel Installation and Cabling Connecting to the PCVideo equipment Connecting to Video EquipmentLoading Batteries Handling the Remote ControllerDegrees degrees About 5m Indicating lamp Power status Turning Power On and OffOperating Instructions Sub input Volume AdjustmentVolume Input SelectionSound Mute Contrast AdjustmentInput Signal Status Display Adjustment status guidanceBrightness On-Screen Display System, EasyMenuMain Menu Picture Sound Display Function Picture Menu ContrastMenu item Selected Adjustment Setup hint Adjustment Item ListSharpness Mute VolumeColor TintMenu item Selected Adjustment NTSC,PAL,SECAM EnglishSwitching inputs Setting an unusedSets to Skip Sets to Select Accelerate switching Do not select when Select whenAutomatic Store Other FeaturesDisplay Registration condition Status Display Example Reset Settings InitializationSignal Check Display menu itemSQ.W Switching the Display MethodSound Mode Power Save ModeSymptoms That Seemingly Appear to be Failures TroubleshootingSymptom Point to check Example SymptomFine pattern flickers when displayed on the screen display Display image appears flowing display 2 RGB inputGeneral Specifications Product SpecificationsGND Signal InputPin Input signal Sync signal type PriorityXGA Recommended Signal ListResolution Horizontal Dot clock Remarks