Runco PL-50DHD, PL-43DHD manual Picture Brightness Contrast Color Tint Sharpness

Page 46

Picture

Picture

Brightness

Contrast

Color

Tint

Sharpness

Use the controls in the Picture Menu to calibrate your PlasmaWall for optimum picture quality.

The PlasmaWall has been designed to incorporate setup and calibration standards established by the Imaging Science Foundation (ISF). The ISF has developed carefully crafted, industry-recognized standards for optimal video performance and has implemented a training program for technicians and installers to use these standards to obtain optimal picture quality from Runco video display devices. Accordingly, Runco recommends that setup and calibration be performed by an ISF certified installation technician.

All signal types require separate processing. Therefore, you need to calibrate each DHD Controller input separately. Runco recommends calibrating the inputs in this order:

1.Component SD

2.S-Video 1 / S-Video 2

3.Composite

4.HD/RGB 1 / HD/RGB 2

5.DVI 1 / DVI 2

When you change a picture quality setting, save the change to a

Note preset afterwards. Otherwise, the change will be lost when a different input is selected. (Picture quality settings are saved for

each input separately.) For information about saving settings, refer to ISF Presets on page 40.

Although it may be possible to obtain satisfactory picture quality using the naked eye and regular program material, Runco recommends using the following calibration tools for best results:

External test pattern source – Ovation Multimedia, Video Essentials or AVIA test DVD (or equivalent).

A blue filter (provided with many test DVDs), for color level and tint adjustments.

Connect your test pattern source to the input that you are calibrating and proceed as follows. Perform the adjustments in the order listed here.

Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an acronym for “Picture Line-Up Generation Equipment.”) Figure 4-2shows a typical PLUGE pattern.

Below Black

Above Black

Figure 4-2. Typical PLUGE Pattern for Adjusting Brightness

36 Runco PL-43DHD and PL-50DHD Owner’s Operating Manual

Image 46
Contents PL-43DHD PL-50DHD Page Three Year Limited Warranty For Plasma DisplaysRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions DOC Compliance NoticeTable of Contents Appendix A. PlasmaWall Service Remote Control Maintenance and TroubleshootingSpecifications OperationList of Figures Page Introduction About This ManualSignificance. They also provide supplemental information Using This ManualCertain features Degrade performance or cause a malfunctionDescription, Features and Benefits Key Features and BenefitsOptional Accessories Controls and Functions Controls and IndicatorsPlasmaWall at a Glance PlasmaWall Connectors Combination IN/OUT Main Power SwitchExternal Speaker Output Right Digital RGB Input 2 DVI-DRunco Icon Power ButtonDHD Controller Front Panel IR SensorEnter Button UP ButtonLeft Button Down ButtonDHD Controller Rear Panel HD1 / HD2 Analog BNC connectorsComponent Video RCA connectors DVI OUTRS-232 Control Port Composite Video InputMain AC Fuse DHD Controller Remote Control DHD Controller Remote ControlLight IR Output IndicatorEnter MenuISF DAY CinemaSVC CustInstallation Remote ControlOther surfaces Installation specialist Quick SetupStep Procedure For Details, refer to High-Altitude Operation InstallationConsiderations Mounting the PlasmaWallAmbient Light VentilationInstallation Connecting PlasmaWall to the DHD Controller Connections to the PlasmaWall and DHD ControllerRS-232 Connection from the DHD Controller to the PlasmaWall Components to the DHD Connecting SourceDVI Connections See Figure DTV or Progressive Component YPbPr Source To work Refer to Computer/Video Signal Compatibility on page 58 forAnalog Computer RGB Connections See Figure Some Macintosh computers may require a Macintosh videoComposite/S-Video/Component Video Connections See Figure Composite, S-Video and Component Video ConnectionsRS-232 Controller Connection11. Installing the Cable Ties Turning on the Power OperationSelecting the Input Source Setting the PC Display Properties You must enter a passcode to access the Service menuOperation Using the On-Screen Menus Input Source ISF PresetsService Aspect RatioAspect Ratio Main MenuInput Source HD Pass Thru 1 HD Pass ThruAspect Ratio Settings Remote Aspect Ratio Control Description KeyPicture Picture Brightness Contrast Color Tint SharpnessTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Input Position ResolutionInput Position Left/Right Up/Down Width Height Overscan Information ISF PresetsISF Presets ISF Night ISF Day Custom Save Factory Default Serial Number Hardware Firmware 0002.001B Date Mar 24Gain/Offset Refer to ISF Night Display Color, above You must enter a passcode to access the Calibration menuCalibration Service Should be used by ISF-certified technicians onlyInput Names Restore Composite Video Component SD Button takes you from top to bottom in the left column, thenMirror Mode HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Operation Troubleshooting Tips Maintenance and TroubleshootingSymptom Possible Causes Solution Computer/Video Signal Value Description Min/max Stored? Power On/Off Commands CommandSerial Communications Aspect Ratio Commands Image Preset Commands Value Description Min/max Stored? Input Position Commands Output Shift CommandsBkgnd Page Specifications are subject to change without notice SpecificationsPlasmaWall Specifications PL-43DHD 380 W PL-50DHD 480 WDHD Controller Specifications PlasmaWall Dimensions PlasmaWall Model PL-43DHD DimensionsPlasmaWall Model PL-50DHD Dimensions Input Refresh Rate Display Quality Refer to Notes Computer/Video Signal CompatibilityResolution Remarks Support Vert Horiz75.1 68.5 Figure A-1. PlasmaWall Service Remote Control OverviewInfo PowerAspect Ratio SET ButtonVideo NR Noise Reduction Mpeg FilterPage Page Runco CL-810 Owner’s Operating Manual