Runco PL-50DHD, PL-43DHD manual Mirror Mode

Page 54

Operation

Analog Out Mode: Select Analog Out Mode from the Service menu to change the characteristics of the analog output signal from the DHD Controller. The choices are RGB-- (separate sync with negative polarity), RGB++ (separate sync with positive polarity) or RGBS (composite sync).

Display Device: The options in the Display Device menu allow you to perform certain adjustments at the plasma display.

Input Source: Select Input Source from the Display Device menu to switch from one DHD Controller output/PlasmaWall input to the other. Use the or button to select RGB or DVI/HDMI, then press ENTER.

Note

Tip

If the DVI 1 or DVI 2 DHD Controller input is active and the input signal is HDCP-encrypted, the RGBHV output of the DHD Controller is disabled.

Use the serial command DISPLAY 1 or DISPLAY 2 to set the Input Source to RGB or DVI/HDMI respectively, so that the DHD Controller retains this setting after a System Reset. (This is not the case when you

change the Input Source in the Display Device menu.) For more information, refer to Miscellaneous Commands on page 53.

Configure: Select Configure from the Display Device menu to perform the following display device adjustments (these are global, independent of any input):

Select Mirror Mode to change the displayed image orientation to suit the installation method; see Figure 4-6.For example, if the PlasmaWall is suspended from a ceiling, you may want to mount it upside down and run the cables upward (toward the ceiling) to make them less visible. In this case, you would use the “XY” mirror mode.

Normal operating state

Left-right reversal

[MIRROR MODE: OFF]

[MIRROR MODE: X]

Up-down, left-right reversal

Up-down reversal

[MIRROR MODE: XY]

[MIRROR MODE: Y]

Figure 4-6. Mirror Mode

Select Left/Right, Up/Down, Width or Height to fine-tune the aspect ratio and image position.

44 Runco PL-43DHD and PL-50DHD Owner’s Operating Manual

Image 54
Contents PL-43DHD PL-50DHD Page Three Year Limited Warranty For Plasma DisplaysRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions DOC Compliance NoticeTable of Contents Appendix A. PlasmaWall Service Remote Control Maintenance and TroubleshootingSpecifications OperationList of Figures Page Introduction About This ManualSignificance. They also provide supplemental information Using This ManualCertain features Degrade performance or cause a malfunctionDescription, Features and Benefits Key Features and BenefitsOptional Accessories Controls and Indicators Controls and FunctionsPlasmaWall at a Glance PlasmaWall Connectors Combination IN/OUT Main Power SwitchExternal Speaker Output Right Digital RGB Input 2 DVI-DRunco Icon Power ButtonDHD Controller Front Panel IR SensorEnter Button UP ButtonLeft Button Down ButtonDHD Controller Rear Panel HD1 / HD2 Analog BNC connectorsComponent Video RCA connectors DVI OUTComposite Video Input RS-232 Control PortMain AC Fuse DHD Controller Remote Control DHD Controller Remote ControlLight IR Output IndicatorEnter MenuISF DAY CinemaSVC CustInstallation Remote ControlOther surfaces Quick Setup Installation specialistStep Procedure For Details, refer to High-Altitude Operation InstallationConsiderations Mounting the PlasmaWallAmbient Light VentilationInstallation Connecting PlasmaWall to the DHD Controller Connections to the PlasmaWall and DHD ControllerRS-232 Connection from the DHD Controller to the PlasmaWall Connecting Source Components to the DHDDVI Connections See Figure DTV or Progressive Component YPbPr Source To work Refer to Computer/Video Signal Compatibility on page 58 forAnalog Computer RGB Connections See Figure Some Macintosh computers may require a Macintosh videoComposite/S-Video/Component Video Connections See Figure Composite, S-Video and Component Video ConnectionsRS-232 Controller Connection11. Installing the Cable Ties Turning on the Power OperationSelecting the Input Source Setting the PC Display Properties You must enter a passcode to access the Service menuOperation Using the On-Screen Menus Input Source ISF PresetsService Aspect RatioAspect Ratio Main MenuInput Source HD Pass Thru 1 HD Pass ThruAspect Ratio Settings Remote Aspect Ratio Control Description KeyPicture Picture Brightness Contrast Color Tint SharpnessTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Resolution Input PositionInput Position Left/Right Up/Down Width Height Overscan Information ISF PresetsISF Presets ISF Night ISF Day Custom Save Factory Default Serial Number Hardware Firmware 0002.001B Date Mar 24You must enter a passcode to access the Calibration menu Gain/Offset Refer to ISF Night Display Color, aboveCalibration Service Should be used by ISF-certified technicians onlyInput Names Restore Composite Video Component SD Button takes you from top to bottom in the left column, thenMirror Mode HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Operation Maintenance and Troubleshooting Troubleshooting TipsSymptom Possible Causes Solution Computer/Video Signal Command Value Description Min/max Stored? Power On/Off CommandsSerial Communications Aspect Ratio Commands Image Preset Commands Value Description Min/max Stored? Input Position Commands Output Shift CommandsBkgnd Page Specifications are subject to change without notice SpecificationsPlasmaWall Specifications PL-43DHD 380 W PL-50DHD 480 WDHD Controller Specifications PlasmaWall Dimensions PlasmaWall Model PL-43DHD DimensionsPlasmaWall Model PL-50DHD Dimensions Input Refresh Rate Display Quality Refer to Notes Computer/Video Signal CompatibilityResolution Remarks Support Vert Horiz75.1 68.5 Figure A-1. PlasmaWall Service Remote Control OverviewInfo PowerAspect Ratio SET ButtonVideo NR Noise Reduction Mpeg FilterPage Page Runco CL-810 Owner’s Operating Manual