Table 6-1. Serial Commands (continued)

Command

Parameter

Value

 

Description

(min/max)

Stored?

 

 

 

 

 

 

 

 

 

Miscellaneous Commands

 

 

 

 

BKGND

-100/100

YES

Sets the background color for 4:3 aspect

 

 

 

ratio (-100 = black; 100 = white)

 

 

 

 

BKGND?

NA

NA

Returns background setting value

 

 

 

 

DATE?

NA

NA

Returns product manufacture date

 

 

 

 

DISPLAY

1 or 2

YES

Sets display device input source

 

 

 

(1 = RGB; 2 = DVI/HDMI)

 

 

 

 

DISPLAY?

NA

NA

Returns display device input source value

 

 

 

 

HDINPUTRES

NA

YES

Sets YPbPr input resolution and refresh

 

 

 

rate for HD1/HD2, as follows:

 

 

 

0

= 480i

 

 

 

1

= 480p

 

 

 

2

= 576i

 

 

 

3

= 576p

 

 

 

4

= 720p / 60 Hz

 

 

 

5

= 1080i / 60 Hz

 

 

 

6

= 720p / 50 Hz

 

 

 

7

= 1080i / 25 Hz

 

 

 

Any other value = Auto

 

 

 

 

HWVER?

NA

NA

Returns hardware version number

 

 

 

 

INRES?

NA

NA

Returns input resolution

 

 

 

 

OUTRES

0/5

YES

Sets output resolution, as follows:

 

 

 

0

= 480i

 

 

 

1

= 576i

 

 

 

2

= 480p

 

 

 

3

= 576p

 

 

 

4

= 720p

 

 

 

5

= 1080i

 

 

 

 

OUTRES?

NA

NA

Returns output resolution

 

 

 

 

RGBNN

NA

NA

Sets output color space to RGB with

 

 

 

negative horizontal and vertical sync

 

 

 

 

RGBPP

NA

NA

Sets output color space to RGB with

 

 

 

positive horizontal and vertical sync

 

 

 

 

RGBS

NA

NA

Sets output color space to RGB with

 

 

 

composite sync

 

 

 

 

SWVER?

NA

NA

Returns software version number

 

 

 

 

TRIGGER

1/3

YES

Assigns trigger to currently-selected aspect

 

 

 

ratio

 

 

 

 

 

Runco PL-43DHD and PL-50DHD Owner’s Operating Manual

53

Image 63
Contents PL-43DHD PL-50DHD Page For Plasma Displays Three Year Limited WarrantyRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC DOC Compliance Notice Safety PrecautionsTable of Contents Operation Maintenance and TroubleshootingSpecifications Appendix A. PlasmaWall Service Remote ControlList of Figures Page About This Manual IntroductionDegrade performance or cause a malfunction Using This ManualCertain features Significance. They also provide supplemental informationKey Features and Benefits Description, Features and BenefitsOptional Accessories Controls and Indicators Controls and FunctionsPlasmaWall at a Glance PlasmaWall Connectors Digital RGB Input 2 DVI-D Main Power SwitchExternal Speaker Output Right Combination IN/OUTIR Sensor Power ButtonDHD Controller Front Panel Runco IconDown Button UP ButtonLeft Button Enter ButtonDVI OUT HD1 / HD2 Analog BNC connectorsComponent Video RCA connectors DHD Controller Rear PanelComposite Video Input RS-232 Control PortMain AC Fuse DHD Controller Remote Control DHD Controller Remote ControlMenu IR Output IndicatorEnter LightCust CinemaSVC ISF DAYRemote Control InstallationOther surfaces Quick Setup Installation specialistStep Procedure For Details, refer to Mounting the PlasmaWall InstallationConsiderations High-Altitude OperationVentilation Ambient LightInstallation Connections to the PlasmaWall and DHD Controller Connecting PlasmaWall to the DHD ControllerRS-232 Connection from the DHD Controller to the PlasmaWall Connecting Source Components to the DHDDVI Connections See Figure DTV or Progressive Component YPbPr Source Some Macintosh computers may require a Macintosh video Refer to Computer/Video Signal Compatibility on page 58 forAnalog Computer RGB Connections See Figure To workComposite, S-Video and Component Video Connections Composite/S-Video/Component Video Connections See FigureConnection RS-232 Controller11. Installing the Cable Ties Operation Turning on the PowerYou must enter a passcode to access the Service menu Selecting the Input Source Setting the PC Display PropertiesOperation Using the On-Screen Menus Aspect Ratio ISF PresetsService Input SourceHD Pass Thru 1 HD Pass Thru Main MenuInput Source Aspect RatioRemote Aspect Ratio Control Description Key Aspect Ratio SettingsPicture Brightness Contrast Color Tint Sharpness PictureTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Resolution Input PositionInput Position Left/Right Up/Down Width Height Overscan Serial Number Hardware Firmware 0002.001B Date Mar 24 ISF PresetsISF Presets ISF Night ISF Day Custom Save Factory Default InformationYou must enter a passcode to access the Calibration menu Gain/Offset Refer to ISF Night Display Color, aboveCalibration Should be used by ISF-certified technicians only ServiceButton takes you from top to bottom in the left column, then Input Names Restore Composite Video Component SDMirror Mode HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Operation Maintenance and Troubleshooting Troubleshooting TipsSymptom Possible Causes Solution Computer/Video Signal Command Value Description Min/max Stored? Power On/Off CommandsSerial Communications Aspect Ratio Commands Image Preset Commands Output Shift Commands Value Description Min/max Stored? Input Position CommandsBkgnd Page PL-43DHD 380 W PL-50DHD 480 W SpecificationsPlasmaWall Specifications Specifications are subject to change without noticeDHD Controller Specifications PlasmaWall Model PL-43DHD Dimensions PlasmaWall DimensionsPlasmaWall Model PL-50DHD Dimensions Vert Horiz Computer/Video Signal CompatibilityResolution Remarks Support Input Refresh Rate Display Quality Refer to Notes75.1 68.5 Overview Figure A-1. PlasmaWall Service Remote ControlSET Button PowerAspect Ratio InfoMpeg Filter Video NR Noise ReductionPage Page Runco CL-810 Owner’s Operating Manual