Runco PL-43DHD, PL-50DHD manual Description, Features and Benefits, Key Features and Benefits

Page 13

Introduction

The PlasmaWall PL-43DHD and PL-50DHD flat-panel plasma monitors bring outstanding picture quality to their respective size categories with true, high-definition native resolution of 1024 x 768 (PL-43DHD) or 1280 x 768 (PL-50DHD) for no-compromise viewing of any video source.

The PlasmaWall is supplied with Runco’s next-generation, Digital High Definition (DHD) Controller, featuring advanced Vivix II™ processing. This controller produces stunning video imagery, elevating even standard NTSC material to near high-definition levels.

Multiple aspect ratio control includes Runco’s VirtualWide™ for viewing 4:3 material in widescreen with no loss of picture quality. The DHD provides for a pure digital signal path from input to output, making this system ready for Runco’s exclusive LiveLink™ DVI cable solution to preserve HD signal quality over long runs.

The PlasmaWall’s black level performance and shadow detail capability have been enhanced with Active Gray Scale Rendering to provide smoother transitions from dark to light, resulting in richly detailed textures even in shadowy scenes.

The PlasmaWall is easily integrated into custom installation systems. Both RS-232C and IR control interfaces are incorporated for simple automation. Its profile is less than 4-1/2 inches thin for wall-mounting simplicity.

The PlasmaWall offers these key features and benefits:

Native Resolution: 1280 x 768 (PL-50DHD) or 1024 x 768 (PL-43DHD)

Multiple Aspect Ratios with VirtualWide™ Mode

160 degree horizontal/vertical viewing angle

Accepts all DTV formats (via outboard decoder), including 1080i, 720p and 480p

Less than five inches deep

DVI Input with High-bandwidth Digital Content Protection (HDCP)

Exceptional detail and artifact-free video enhancement

Vivix™ video processing with 3:2 film detection circuitry

1.3

Description, Features and Benefits

Key Features and Benefits

Runco PL-43DHD and PL-50DHD Owner’s Operating Manual

3

Image 13
Contents PL-43DHD PL-50DHD Page For Plasma Displays Three Year Limited WarrantyRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC DOC Compliance Notice Safety PrecautionsTable of Contents Specifications Maintenance and TroubleshootingAppendix A. PlasmaWall Service Remote Control OperationList of Figures Page About This Manual IntroductionCertain features Using This ManualSignificance. They also provide supplemental information Degrade performance or cause a malfunctionKey Features and Benefits Description, Features and BenefitsOptional Accessories Controls and Functions Controls and IndicatorsPlasmaWall at a Glance PlasmaWall Connectors External Speaker Output Right Main Power SwitchCombination IN/OUT Digital RGB Input 2 DVI-DDHD Controller Front Panel Power ButtonRunco Icon IR SensorLeft Button UP ButtonEnter Button Down ButtonComponent Video RCA connectors HD1 / HD2 Analog BNC connectorsDHD Controller Rear Panel DVI OUTRS-232 Control Port Composite Video InputMain AC Fuse DHD Controller Remote Control DHD Controller Remote ControlEnter IR Output IndicatorLight MenuSVC CinemaISF DAY CustRemote Control InstallationOther surfaces Installation specialist Quick SetupStep Procedure For Details, refer to Considerations InstallationHigh-Altitude Operation Mounting the PlasmaWallVentilation Ambient LightInstallation Connections to the PlasmaWall and DHD Controller Connecting PlasmaWall to the DHD ControllerRS-232 Connection from the DHD Controller to the PlasmaWall Components to the DHD Connecting SourceDVI Connections See Figure DTV or Progressive Component YPbPr Source Analog Computer RGB Connections See Figure Refer to Computer/Video Signal Compatibility on page 58 forTo work Some Macintosh computers may require a Macintosh videoComposite, S-Video and Component Video Connections Composite/S-Video/Component Video Connections See FigureConnection RS-232 Controller11. Installing the Cable Ties Operation Turning on the PowerYou must enter a passcode to access the Service menu Selecting the Input Source Setting the PC Display PropertiesOperation Using the On-Screen Menus Service ISF PresetsInput Source Aspect RatioInput Source Main MenuAspect Ratio HD Pass Thru 1 HD Pass ThruRemote Aspect Ratio Control Description Key Aspect Ratio SettingsPicture Brightness Contrast Color Tint Sharpness PictureTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Input Position ResolutionInput Position Left/Right Up/Down Width Height Overscan ISF Presets ISF Night ISF Day Custom Save Factory Default ISF PresetsInformation Serial Number Hardware Firmware 0002.001B Date Mar 24Gain/Offset Refer to ISF Night Display Color, above You must enter a passcode to access the Calibration menuCalibration Should be used by ISF-certified technicians only ServiceButton takes you from top to bottom in the left column, then Input Names Restore Composite Video Component SDMirror Mode HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Operation Troubleshooting Tips Maintenance and TroubleshootingSymptom Possible Causes Solution Computer/Video Signal Value Description Min/max Stored? Power On/Off Commands CommandSerial Communications Aspect Ratio Commands Image Preset Commands Output Shift Commands Value Description Min/max Stored? Input Position CommandsBkgnd Page PlasmaWall Specifications SpecificationsSpecifications are subject to change without notice PL-43DHD 380 W PL-50DHD 480 WDHD Controller Specifications PlasmaWall Model PL-43DHD Dimensions PlasmaWall DimensionsPlasmaWall Model PL-50DHD Dimensions Resolution Remarks Support Computer/Video Signal CompatibilityInput Refresh Rate Display Quality Refer to Notes Vert Horiz75.1 68.5 Overview Figure A-1. PlasmaWall Service Remote ControlAspect Ratio PowerInfo SET ButtonMpeg Filter Video NR Noise ReductionPage Page Runco CL-810 Owner’s Operating Manual