Setup menus (continued)
USER menu | <INTERFACE> | ||
|
|
|
|
No./Item |
|
| Description |
|
| ||
|
| ||
200 | This selects whether two or more VTRs are | ||
| to be operated in synchronization. | ||
PARA RUN |
|
|
|
|
| 0000 | DIS : No operation in synchronization |
|
| 0001 | ENA : Operation in synchronization |
| <Note> |
| |
| When operating two or more VTRs in | ||
| synchronization, set all the VTRs to ENA. | ||
|
| ||
201 | This selects whether the 9P connector is to | ||
| function when the REMOTE button is set to | ||
9P SEL | the remote mode (REMOTE lamp ON). | ||
|
| 0000 | OFF : Connector does not function. |
|
| 0001 | ON : Connector functions. |
|
| ||
202 | This sets the ID information to be returned to | ||
| the controller. | ||
ID SEL |
|
|
|
|
| 0000 | OTHER |
|
| 0001 DVCPRO | |
|
| 0002 | ORIG |
| <Notes> | ||
| OID information of any VTR except for the | ||
|
| DVCPRO’s is set in OTHER. | |
| OThe ORIG setting should only be used when a | ||
|
| Panasonic controller | |
|
| separately) is connected. | |
|
| ||
203 | This selects whether the PARALLEL (25P) | ||
| connector is to function when the REMOTE | ||
25P SEL | button is set to the remote mode (REMOTE | ||
| lamp ON). | ||
|
| 0000 | OFF : Connector does not function. |
|
| 0001 | ON : Connector functions. |
|
| ||
204 | This selects whether the | ||
| is to function when the REMOTE button is | ||
RS232C SEL | set to the remote mode (REMOTE lamp ON). | ||
|
| 0000 | OFF : Connector does not function. |
|
| 0001 | ON : Connector functions. |
|
| ||
205 | These settings are for selecting the | ||
| communication speed (baud rate). | ||
BAUD RATE |
|
|
|
|
| 0000 | 300 |
|
| 0001 | 600 |
|
| 0002 | 1200 |
|
| 0003 | 2400 |
|
| 0004 | 4800 |
|
| 0005 | 9600 |
|
| ||
206 | These settings are for selecting the | ||
| data length. (Unit: bit) | ||
DATA LENGTH |
|
|
|
|
| 0000 | 7 |
|
| 0001 | 8 |
|
| ||
207 | These settings are for selecting the | ||
| stop bit length. (Unit: bit) | ||
STOP BIT |
|
|
|
|
| 0000 | 1 |
|
| 0001 | 2 |
|
|
|
|
No./Item |
| Description |
|
| |
|
| |
208 | These settings are for selecting the none, | |
| odd or even for the | |
PARITY |
|
|
| 0000 | NON : |
| Parity bit is not used. | |
| 0001 | ODD: |
| An odd number of bits is used for the parity | |
| system. | |
| 0002 | EVEN: |
| An even number of bits is used for the parity | |
| system. | |
|
| |
209 | These settings are for selecting whether the | |
| ACK code is to be returned when a command | |
RETURN ACK | is received from | |
| 0000 | OFF : ACK code is not returned. |
| 0001 | ON : ACK code is returned. |
|
| |
210 | For selecting the method used to detect the | |
| STANDBY COMMAND signal input at the | |
25P STBY CMD | PARALLEL (25P) connector. | |
| 0000 | OFF/ON : |
| Each time active signals are detected, the | |
| STANDBY ON or STANDBY OFF mode is | |
| selected alternately. | |
| 0001 | ON : |
| When active signals are detected in the | |
| STANDBY OFF mode, the unit is transferred | |
| to the STANDBY ON mode. | |
| Nothing happens if they are detected during | |
| an operation in the STANDBY ON mode. | |
|
| |
211 | This selects whether the PARALLEL (25P) | |
| connector is to function when the REMOTE | |
LOCAL 25P | button is set to the local mode (REMOTE | |
| lamp OFF). | |
| 0000 | OFF : Connector does not function. |
| 0001 | ON : Connector functions. |
|
| |
212 | For selecting the remote control connector to | |
| control the slave when the unit is used as the | |
MASTER PORT | master during | |
| 0000 | IN/OUT : The IN/OUT connector is used. |
| 0001 | OUT : The OUT connector is used. |
| <Note> | |
| This setting takes effect only when the REMOTE | |
| button is set to the local mode (REMOTE lamp | |
| OFF). |
|
|
|
|
The underlined items indicates the initial setting.
45