Setup menus (continued)
USER menu | <TIME CODE> |
| |||
|
|
|
|
| |
No./Item |
|
|
| Description | |
|
| ||||
|
| ||||
500 | For selecting whether to output the VITC | ||||
| signal at the positions selected by setup | ||||
VITC BLANK | menu items No. 501 (VITC | ||||
| 502 (VITC |
| |||
|
| 0000 | BLANK : VITC signals are not output. | ||
|
| 0001 | THRU : VITC signals are output. | ||
|
| ||||
501 | This sets the position where the VITC signal | ||||
| is to be inserted. |
| |||
VITC |
|
|
|
|
|
|
| [625i system] | [525i system] | ||
|
| 0000 | 7L | 0000 | 10L |
|
| : | : | : | : |
|
| 0004 | 11L | 0006 | 16L |
|
| : | : | : | : |
|
| 0015 | 22L | 0010 | 20L |
| <Note> |
|
| ||
| The same line as the one used for the setup | ||||
| menu items No. 502 (VITC | ||||
| (UMID POS) setting cannot be set. | ||||
|
| ||||
502 | This sets the position where the VITC signal | ||||
| is to be inserted. |
| |||
VITC |
|
|
|
|
|
|
| [625i system] | [525i system] | ||
|
| 0000 | 7L | 0000 | 10L |
|
| : | : | : | : |
|
| 0006 | 13L | 0008 | 18L |
|
| : | : | : | : |
|
| 0015 | 22L | 0010 | 20L |
| <Note> |
|
| ||
| The same line as the one used for the setup | ||||
| menu items No. 501 (VITC | ||||
| (UMID POS) setting cannot be set. | ||||
|
| ||||
503 | This selects the signal to be regenerated | ||||
| when the time code generator (TCG) in the | ||||
TCG REGEN | REGEN mode. |
|
| ||
|
| 0000 | TC&UB : |
|
|
|
| Both the time code and user bit are | |||
|
| regenerated. |
|
| |
|
| 0001 | TC : |
|
|
|
| Only the time code is regenerated. | |||
|
| 0002 | UB : |
|
|
|
| Only the user bit is regenerated. | |||
|
| ||||
504 | This selects whether the time code is to be | ||||
| regenerated during automatic editing using | ||||
REGEN MODE | the unit’s control panel. |
| |||
|
| 0000 | AS&IN : |
|
|
|
| Time code is regenerated with assemble or | |||
|
| insert editing. |
|
| |
|
| 0001 | ASSEM : |
|
|
|
| Time code is regenerated with assemble | |||
|
| editing. |
|
| |
|
| 0002 | INSRT : |
|
|
|
| Time code is regenerated with insert editing. | |||
|
| 0003 | SW : |
|
|
|
| Setting complies with TC (REGEN/PRESET) | |||
|
| switch setting. |
|
| |
|
|
|
|
|
|
No./Item |
| Description |
|
| |
|
| |
505 | This selects the time code to be used when | |
| an external time code is to be used. | |
EXT TC SEL |
|
|
| 0000 | LTC : |
| The LTC of the TIME CODE IN connector is | |
| used. |
|
| 0001 | VITC : |
| The VITC of the input video signal is used. | |
|
| |
506 | This sets the usage status of the user bit of | |
| the time code generated by the TCG. | |
BINARY GP |
|
|
| 0000 | 000 : |
| NOT SPECIFIED (character set not specified) | |
| 0001 | 001 : |
| ISO CHARACTER (8 bits character set based | |
| on ISO646, ISO2022) | |
| 0002 | 010 : UNASSIGNED 1 (undefined) |
| 0003 | 011 : UNASSIGNED 2 (undefined) |
| 0004 | 100 : UNASSIGNED 3 (undefined) |
| 0005 | 101 : PAGE/LINE |
| 0006 | 110 : UNASSIGNED 4 (undefined) |
| 0007 | 111 : UNASSIGNED 5 (undefined) |
|
| |
507 | This selects whether to control the phase | |
| correction of the LTC which is output from | |
PHASE CORR | the TIME CODE OUT connector. | |
| 0000 | OFF : |
| Phase correction control is not performed. | |
| 0001 | ON : |
| Phase correction control is performed. | |
|
| |
508 | This selects whether the CF flag of the TCG | |
| is to ON. | |
TCG CF FLAG |
|
|
| 0000 | OFF : CF flag is OFF. |
| 0001 | ON : CF flag is ON. |
|
| |
509 | This selects the DF or NDF mode for CTL and | |
| TCG. |
|
DF MODE |
|
|
| 0000 | DF : The drop frame mode is used. |
| 0001 | NDF : The |
|
| used. |
| <Notes> | |
| OThe drop frame mode takes effect when the | |
| REMOTE button is set to the local mode | |
| (REMOTE lamp OFF) or when ENA has been | |
| selected as the setup menu item No.001 | |
| (LOCAL ENA). | |
| OThis setup menu is not displayed in the 625i | |
| system. | |
|
| |
510 | This is used to switch the phase of the time | |
| code, which is output from the TIME CODE | |
TC OUT REF | OUT connector, for the external LTC input | |
| when the TCG switch is at the EXT position. | |
| 0000 | V OUT : |
| Time code is synchronized with output video | |
| signal. | |
| 0001 | TC_IN : |
| Time code is synchronized with external time | |
| code input. | |
|
|
|
The underlined items indicates the initial setting.
49