Error messages (continued)
Error messages
Display | ODescription | |
OVTR operation and corrective action | ||
| ||
|
| |
|
| |
If condensation is detected, the error number | ||
| flashes and the unit transfers to eject mode. The | |
DEW | drum rotates after the cassette is ejected to | |
| eliminate the condensation. | |
| Once the unit is released from condensation | |
| status, the error message display is cleared and | |
| the VTR is able to be used. | |
| OIf condensation is detected in the eject mode, | |
| the drum starts rotating as soon as it is | |
| detected. | |
| OIf condensation is detected when the cassette | |
| has been inserted, the drum rotation is | |
| stopped, and after the tape is ejected, the | |
| drum starts rotating. | |
| VTR: EJECT | |
| OLeave the power on and wait. | |
|
| |
The unit switches to eject mode and if the | ||
| cassette fails to move up within 6 seconds, this | |
FRONT LOAD | error number flashes on the display. | |
MOTOR | OIf the cassette does not move down inside the | |
| machine even when 6 seconds have elapsed | |
| since the cassette was inserted, the VTR is | |
| transferred to the eject mode. | |
| VTR: STOP | |
| OSet the POWER switch to OFF and then to | |
| ON again. | |
|
| |
If the unloading operation is not completed | ||
| within 6 seconds, this error number flashes on | |
LOADING | the display. | |
MOTOR | OWhen the loading operation is not completed | |
| within 6 seconds, the VTR is transferred to | |
| the eject (unloading) mode. | |
| VTR: STOP | |
| OSet the POWER switch to OFF and then to | |
| ON again. | |
|
| |
If there is no response from the servo | ||
| microcomputer for 1 second or more, this error | |
SERVO | number flashes on the display. | |
CONTROL | VTR: STOP | |
ERROR | OSet the POWER switch to OFF and then to | |
| ON again. | |
|
| |
If 10 seconds or more elapses and the servo | ||
| microcomputer has not followed orders issued | |
SERVO COMM | by the system control microcomputer, this error | |
ERROR | number flashes on the display. | |
| VTR: STOP | |
| OSet the POWER switch to OFF and then to | |
| ON again. | |
|
| |
If automatic adjustment of the reel and capstan | ||
| rotation in eject status was not performed | |
SERVO FG | correctly when the power was turned on, this | |
ERROR | error number flashes on the display. | |
| VTR: STOP | |
| OSet the POWER switch to OFF and then to | |
| ON again. | |
|
|
Display | ODescription | |
OVTR operation and corrective action | ||
| ||
|
| |
|
| |
If the | ||
| specific period of time during the start or end | |
FRONT LOAD | processing operation while loading is underway | |
ERROR | (half position), this error number flashes on the | |
| display. | |
| VTR: STOP | |
| OSet the POWER switch to OFF and then to | |
| ON again. | |
|
| |
If the | ||
| the tape is traveling in the state where the total | |
amount of the tape has not yet been detected | ||
NOT ROTA | after the cassette was inserted, this error | |
| number flashes on the display. | |
| VTR: STOP | |
| OSet the POWER switch to OFF and then to | |
| ON again. | |
|
| |
If there is an abnormally large discrepancy | ||
| between the amount of tape taken up by the | |
WINDUP | ||
ERROR | the supply reel while the tape is traveling after | |
| the total amount of the tape begins to be | |
| detected, this error number flashes on the | |
| display. | |
| VTR: STOP | |
| OSet the POWER switch to OFF and then to | |
| ON again. | |
|
| |
If the tape has not been taken up during | ||
| unloading, this error number flashes on the | |
UNLOAD | display. | |
ERROR | VTR: STOP | |
| OSet the POWER switch to OFF and then to | |
| ON again. | |
|
| |
If the start or end processing operation is not | ||
| completed, this error number flashes on the | |
display. | ||
TIMEOVER | VTR: STOP | |
| OSet the POWER switch to OFF and then to | |
| ON again. | |
|
| |
If the cylinder motor speed is abnormally low, | ||
| this error number flashes on the display. | |
DRUM ROTA | VTR: STOP | |
TOO SLOW | OSet the POWER switch to OFF and then to | |
| ON again. | |
|
| |
If the cylinder motor speed is abnormally high, | ||
| this error number flashes on the display. | |
DRUM ROTA | VTR: STOP | |
TOO FAST | OSet the POWER switch to OFF and then to | |
| ON again. | |
|
| |
If the capstan motor speed is abnormally low, | ||
| the error number flashes on the display. | |
CAP ROTA | VTR: STOP | |
TOO SLOW | OSet the POWER switch to OFF and then to | |
| ON again. | |
|
|
74