Error messages (continued)

Error messages

Display

ODescription

OVTR operation and corrective action

 

 

 

 

 

E-20

If condensation is detected, the error number

 

flashes and the unit transfers to eject mode. The

DEW

drum rotates after the cassette is ejected to

 

eliminate the condensation.

 

Once the unit is released from condensation

 

status, the error message display is cleared and

 

the VTR is able to be used.

 

OIf condensation is detected in the eject mode,

 

the drum starts rotating as soon as it is

 

detected.

 

OIf condensation is detected when the cassette

 

has been inserted, the drum rotation is

 

stopped, and after the tape is ejected, the

 

drum starts rotating.

 

VTR: EJECT

 

OLeave the power on and wait.

 

 

E-29

The unit switches to eject mode and if the

 

cassette fails to move up within 6 seconds, this

FRONT LOAD

error number flashes on the display.

MOTOR

OIf the cassette does not move down inside the

 

machine even when 6 seconds have elapsed

 

since the cassette was inserted, the VTR is

 

transferred to the eject mode.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-31

If the unloading operation is not completed

 

within 6 seconds, this error number flashes on

LOADING

the display.

MOTOR

OWhen the loading operation is not completed

 

within 6 seconds, the VTR is transferred to

 

the eject (unloading) mode.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-35

If there is no response from the servo

 

microcomputer for 1 second or more, this error

SERVO

number flashes on the display.

CONTROL

VTR: STOP

ERROR

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-37

If 10 seconds or more elapses and the servo

 

microcomputer has not followed orders issued

SERVO COMM

by the system control microcomputer, this error

ERROR

number flashes on the display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-38

If automatic adjustment of the reel and capstan

 

rotation in eject status was not performed

SERVO FG

correctly when the power was turned on, this

ERROR

error number flashes on the display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

Display

ODescription

OVTR operation and corrective action

 

 

 

 

 

E-51

If the take-up reel rotates without engaging for a

 

specific period of time during the start or end

FRONT LOAD

processing operation while loading is underway

ERROR

(half position), this error number flashes on the

 

display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-52

If the take-up reel fails to take up the tape while

 

the tape is traveling in the state where the total

W-UP REEL

amount of the tape has not yet been detected

NOT ROTA

after the cassette was inserted, this error

 

number flashes on the display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-53

If there is an abnormally large discrepancy

 

between the amount of tape taken up by the

WINDUP

take-up reel and the amount of tape supplied by

ERROR

the supply reel while the tape is traveling after

 

the total amount of the tape begins to be

 

detected, this error number flashes on the

 

display.

 

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-55

If the tape has not been taken up during

 

unloading, this error number flashes on the

UNLOAD

display.

ERROR

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-57

If the start or end processing operation is not

 

completed, this error number flashes on the

S-FF/REW

display.

TIMEOVER

VTR: STOP

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-59

If the cylinder motor speed is abnormally low,

 

this error number flashes on the display.

DRUM ROTA

VTR: STOP

TOO SLOW

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-60

If the cylinder motor speed is abnormally high,

 

this error number flashes on the display.

DRUM ROTA

VTR: STOP

TOO FAST

OSet the POWER switch to OFF and then to

 

ON again.

 

 

E-61

If the capstan motor speed is abnormally low,

 

the error number flashes on the display.

CAP ROTA

VTR: STOP

TOO SLOW

OSet the POWER switch to OFF and then to

 

ON again.

 

 

74

Image 74
Contents Operating Instructions Model No. AJOperating precaution $ this Equipment Must be GroundedIt also Contains Lead Some Components Contents IntroductionFeatures Features Parts and their functions Front panelParts and their functions Recorder Player and Recorder buttonsPlayer Search buttonPreview ReviewVideo AudioWhen the Audio MIX switch is set to 3&4 Audio MIX switchWhen the Audio MIX switch is set to 1&2 VAR RECUnity Local PresetRemote RegenMenu TC PresetShift button Display panel Edit REC REC INHOUT Rear panelIN/OUT Cmonitor OUT connectors Parallel Remote connectorAnalog Audio OUT connectors = Signal GND terminalRecorder ConnectionsSource machine OFFIN/OUT ConnectionsConnections with editing controller Cassettes TapesConsumer-use DV and Dvcam cassettes XL cassettesJog mode Jog/ShuttleAssemble Manual editingPreroll InsertWhen using the AJ-SD965 as the player Switch settings and adjustmentsWhen using the AJ-SD965 as the recorder Automatic editing deck-to-deckAssem Selecting the editing modeAutomatic editing deck-to-deck Match frame processing functionHow to calculate the duration Checking and previewing edit pointsModifying edit points Re-registering an edit pointRetry function Executing and reviewing automatic editingPost-rolling Auto tag function recorder sideAudio split editing Between the video in and OUT points Audio split editing$ Duration display Between the audio in and OUT points$ Releasing variable memory mode Variable memory editing operation procedure$ Selecting the variable memory mode Variable memory editingPF Programmable Function functions Registering setup items in the PF buttonsOperations using the PF buttons Changing the settings Setup initial settingsChanging the file Setup menusSetting and releasing the lock mode SystemLock mode can be set Counter display Setup menusLock mode can be set Loading user filesSaving user files Menu screenSystem menu Local SYS H OffsetSYS SC/H BrightUser menu BasicChara Type Chara H-POSChara V-POS SYS FormatOperation Memory stop function Eject Lamp REC INH LampEject SW INH Interface Edit Confi Edit Edit RPLCE4Edit Rplcec AUD EditTape Protect Time Code TC OUT ADV Vitc OUTSBC EditOUT Vsync YC SEP ModeINT SG Mute SELSetup ESR ModeCCR Mode CmpstCC REC Wide SelectINT Umid RECUmid GEN Umid POSCH3 in LV CH1 in LVCH2 in LV CH4 in LVCUE REC CUE Moni CH SELPCM PB FadeREC PT Mute User menu AudioDV PB ATT CUE OUT Moni CH MON Auto SELREC LINE1 BlankADD Line REC LINE2Teletext SEL REC LINE3REC LINE4 Number of lines which can be set for Teletext LCD Time code Setting the internal time codeTime code/user bit User bitLTC Setting the external time codeTime code/user bit VitcCharacters displayed Operation modeSuperimpose screen Display positionExternal synchronization of video output signals Internal synchronizationVideo output signals and servo reference signal Servo reference signalFade is performed instantaneously to eliminate the noise Audio signal aAudio V fade function Monitor output channel Printed circuit boardAudio recording channel F1 board AudioInner member Rack mountingRack-mounting adaptors Standard rack Fasten it to the rack with set screwsCondensation Video head cleaningMaintenance Attaching the dust cover$ Displaying the Diag menu Error messagesDiag menu $ Warning information display$ Umid information display Error messages$ Displaying the Hours Meter information No RF High Error RateFAN Stop Servo not LockedError messages Reel Torque VTR Stop ErrorReel Rota VTR Stop TOO Fast Torque ERR VTR StopConnector specifications Hardware specificationsExternal interface specifications RS-232C interfaceCommunication parameters Software specifications ProtocolRS-232C interface Send format controller PC 5 VTRReturn format VTR 5 controller PC Error code table$ When the communication has terminated normally Command table $ Commands relating to operation controlRequest $ Commands relating to inquiriesCTL/TC Data STX QCD ETX StatusRemote OUT Connector signalsRemote IN/OUT SUB 25-pin crossover cable supported Connector signalsRS-232C $Digital video Specifications$Video input connector $Digital IN/Analog component OUTSpecifications Other Input/Output ConnectorsMemo Western Zone Panasonic Broadcast & Television Systems CompanyEastern Zone Technical Support