Kathrein MSK 25 manual SAT measurement, Standard Change-Over, Press 2ndF STD, =Analogue =Dvbs

Page 17

SAT measurement

Standard Change-Over

In SAT mode, the MSK 25 receives

analogue signals and

DVB-S signals.

SAT Menu Standard Change-Over

À

[2ndF] [STD]

calling up menu standard change-over:

[1] to [2]

select standard

 

1 = analogue

2 = digital (DVB-S)

Examples

Calling up DVB-S standard

Press [2ndF] [STD]

 

 

The LC display indicates the following options:

1=ANALOGUE

2=DVBS

1=27500 2=24500 3=22000 4= USER

1 = analogue standard

2 = digital (DVB-S) standard

When selecting ‚2‘ you will get to the symbol-rate-selection The LC display indicates the following options:

Under the position 4=USER you can enter sample rates from 1,500 up to 32,000 ks and close with ENTER.

Standard menu

 

 

FR:1288.0MHz

SAT

LEV: 66.5dBuV

D

 

 

 

 

Display for DVB-S measurement

When you have selected an option, you will leave the standard menu and the instrument will be set to DVB measurement.

The display indicates ‘D’.

17

Image 17
Contents MSK 25 Satellite/TV/FM Test Receiver analogue/digital Preface Contents Mpeg Picture Representation option in DVB-C or DVB-T option Safety Rules Signs and SymbolsGeneral Information Additionally included in DeliveryPage Qpsk Overview of FunctionsQAM CofdmLNB 0/5 20 SAT Technical DataDVB-S-MER1 Control Elements Control Elements and IndicatorsConnections right hand side TFT Colour ScreenSAT/DVB-S TV/DVB-C/*DVB-T Short Cut OverviewRF Input Socket ConnectionsExternal DC Voltage Supply Scart OutputSwitching-Off Switching-UpCommissioning Software Accu −−−−− LEV 48.5dBuVFactory Setting on Delivery Setup-MenuSetup Menu Setting Setup Menu Call-UpMains Operation Mains Operation and Battery OperationBattery Operation Standard Change-Over SAT measurement2ndF STD Press 2ndF STDSAT Menu Frequency Entry Frequency Display and Frequency EntryExample FR1508.0MHz LEV 86.5dBuVLevel Overflow and Level Underflow SAT Analogue Level MeasurementSAT DVB-S Level Measurement Locating Satellites Calling up Scan mode Press 2ndF ScanScan Menu LEV-Range2 SAT Example 2ndF 2ndF ExitPress 2ndF Level Bearing for Individual Reception FrequenciesBearing Menu LEV-Range2 SAT Example Bwnarrow SAT Analogue Sound Carrier FrequencyPress 2ndF SC Mpeg Picture Representation option in DVB-S DVB-S MER, BER and Offset MeasurementCalling up DVB-S measurement MER12.6dB MHz BER1.7e-7Press 2ndF LNB LNB Voltage and 22 kHz/60 Hz Change-OverPress 2nF LNB Example LNB14,0V 22kHz 150mAOr + DiSEqC Digital Satellite Equipment ControlHEX Framing Byte MenuPress 2ndF SAT-CTRL Hex Byte Description Address Byte MenuCommand Byte Menu SAT measurement Data Byte Menu Simple Tone Burst DiSEqC2ndF SAT-CTRL 2ndF 2ndF=ANALOG 3=DVBT TV measurementBis DVB-C/DVB-T Change-Over Channel display and channel entry TV Channel Setting Menu Example CHS.11 LEV 62,5dBuVChanging over to special channel Press ./S 1Then press 1 7 5 ./S 2 5 Enter TV Frequency Entry Mode Example CH175,25 LEV 65,0dBuVTV/DVB-C/DVB-T Level Measurement Level Measurement TV AnalogueLEV.dBuV LEV.dBuVLEV-RANGE2 TV Bearing Menu2ndF SC Sound Carrier Distance and Sound Carrier LevelTT1 TT2 Example SC 5.85 MHz BER=2.145E-05 Nicam Sound Bit Error Rate MeasurementMpeg Picture Representation option in DVB-C or DVB-T option DVB-C/DVB-T option, MER, BER and Offset MeasurementMER30.5dB MHz BER2.0e-8 Calling up DVB-C/DVB-T option measurementFrequency Indication and Frequency Entry FM measurementFM Frequency Entry Menu Example LEV 65.0dBuV Then press 9 9 ./S 2 5 EnterFR104.80MHz LEV .dBuV FR104,80MHz LEV¯¯¯.¯dBuV Level MeasurementFr104.80MHz LEV 86.5dBuV LEV-RANGE2 FM SAT Spectrum Spectrum MeasurementTV Spectrum SAT-FullTV Spectrum Menu TV-Full FM SpectrumVHF UHF TV-NarrowCustomer Service MaintenanceChanging the Battery +14.1 dB Signal-to-Noise-RatioTechnical Appendix Instruction Set for 9xx Kathrein Matrix Production Run DiSEqC Commands for Kathrein MatricesInstruction Set for EXR 20 Kathrein Matrix Instruction Set for EXR 22 Kathrein MatrixVRF-CCIR URF-CCIR Channel TablesVHF UHF III Technical Appendix Technical Appendix Technical Appendix Technical Appendix 936.2642/D/1005/ZWT Subject to technical modifications