SAT measurement

Command Byte Menu

À

MSK 25 can send commands under DiSEqC™ 1.0 but cannot receive them. All the commands requiring DiSEqC™ 2.0 (sending and receiving) are underlined grey in the table below.

Commands in bold are particularly preferred for KATHREIN switching matrices.

Hex Byte

Command

Description

Numbe

 

 

 

r of

 

 

 

data

 

 

 

bytes

00

Reset

Reset DiSEqC™ Microcontroller

-

01

Clr Reset

Delete reset flag

-

02

Stand-by

Switching off peripheral power supply unit

-

03

Power on

Switching on peripheral power supply unit

-

04

Set Contend

Adjustment of contention flag

-

05

Contend

Feedback only if contention flag has been set

-

06

Clr Contend

Delete contention flag

-

07

Adresse

Feedback only if contention flag has not been set

-

08

Move C

Change address when contention flag has been set

1

09

Move

Change address when contention flag has not been set

1

10

Status

Read status register flags

-

11

Config

Read configuration flags

-

14

Switch 0

Read switching status flags (Committed Port)

-

15

Switch 1

Read switching state flags (Uncommitted Port)

-

16

Switch 2

Expansion option

-

17

Switch 3

Expansion option

-

20

Set LO

Calling up of low local oscillator frequency

-

21

Set VR

Calling up the vertical polarisation or clockwise circular

-

 

 

polarisation

 

22

Set Pos A

Select satellite position A

-

23

Set S0A

Select switchoption A

-

24

Set Hi

Calling up of high local oscillator frequency

-

25

Set HL

Calling up of horizontal polarisation or counter-clockwise

-

 

 

circular polarisation

 

26

Set Pos B

Select Satellitenposition B

-

27

Set S0B

Select switchoption B

-

28

Set S1A

Calling up of matrix S1 input A (input B inactive)

-

29

Set S2A

Calling up of matrix S2 input A (input B inactive)

-

2A

Set S3A

Calling up of matrix S3 input A (input B inactive)

-

2B

Set S4A

Calling up of matrix S4 input A (input B inactive)

-

2C

Set S1B

Calling up of matrix S1 input B (input A inactive)

-

2D

Set S2B

Calling up of matrix S2 input B (input A inactive)

-

2E

Set S3B

Calling up of matrix S3 input B (input A inactive)

-

2F

Set S4B

Calling up of matrix S4 input B (Eingang A inactive)

-

30

Sleep

All bus commands ignored, except „Awake“

-

31

Awake

Bus commands again accepted

-

38

Write N0

Setting Port Group 0

1

39

Write N1

Setting Port Group 1

1

3A

Write N2

Expansion option

1

3B

Write N3

Expansion option

1

40

Read A0

Read analogue value A0

-

41

Read A1

Read analogue value A1

-

48

Write A0

Set analogue value A0

1

49

Write A1

Set analogue value A1

1

29

Image 29
Contents MSK 25 Satellite/TV/FM Test Receiver analogue/digital Preface Contents Mpeg Picture Representation option in DVB-C or DVB-T option Safety Rules Signs and SymbolsGeneral Information Additionally included in DeliveryPage Qpsk Overview of FunctionsQAM CofdmLNB 0/5 20 SAT Technical DataDVB-S-MER1 Control Elements Control Elements and IndicatorsConnections right hand side TFT Colour ScreenSAT/DVB-S TV/DVB-C/*DVB-T Short Cut OverviewRF Input Socket ConnectionsExternal DC Voltage Supply Scart OutputSwitching-Off Switching-UpCommissioning Software Accu −−−−− LEV 48.5dBuVFactory Setting on Delivery Setup-MenuSetup Menu Setting Setup Menu Call-UpMains Operation Mains Operation and Battery OperationBattery Operation Standard Change-Over SAT measurement2ndF STD Press 2ndF STDSAT Menu Frequency Entry Frequency Display and Frequency EntryExample FR1508.0MHz LEV 86.5dBuVLevel Overflow and Level Underflow SAT Analogue Level MeasurementSAT DVB-S Level Measurement Locating Satellites Calling up Scan mode Press 2ndF ScanScan Menu LEV-Range2 SAT Example 2ndF 2ndF ExitPress 2ndF Level Bearing for Individual Reception FrequenciesBearing Menu LEV-Range2 SAT Example Bwnarrow SAT Analogue Sound Carrier FrequencyPress 2ndF SC Mpeg Picture Representation option in DVB-S DVB-S MER, BER and Offset MeasurementCalling up DVB-S measurement MER12.6dB MHz BER1.7e-7Press 2ndF LNB LNB Voltage and 22 kHz/60 Hz Change-OverPress 2nF LNB Example LNB14,0V 22kHz 150mAOr + DiSEqC Digital Satellite Equipment ControlHEX Framing Byte MenuPress 2ndF SAT-CTRL Hex Byte Description Address Byte MenuCommand Byte Menu SAT measurement Data Byte Menu Simple Tone Burst DiSEqC2ndF SAT-CTRL 2ndF 2ndF=ANALOG 3=DVBT TV measurementBis DVB-C/DVB-T Change-Over Channel display and channel entry TV Channel Setting Menu Example CHS.11 LEV 62,5dBuVChanging over to special channel Press ./S 1Then press 1 7 5 ./S 2 5 Enter TV Frequency Entry Mode Example CH175,25 LEV 65,0dBuVTV/DVB-C/DVB-T Level Measurement Level Measurement TV AnalogueLEV.dBuV LEV.dBuVLEV-RANGE2 TV Bearing Menu2ndF SC Sound Carrier Distance and Sound Carrier LevelTT1 TT2 Example SC 5.85 MHz BER=2.145E-05 Nicam Sound Bit Error Rate MeasurementMpeg Picture Representation option in DVB-C or DVB-T option DVB-C/DVB-T option, MER, BER and Offset MeasurementMER30.5dB MHz BER2.0e-8 Calling up DVB-C/DVB-T option measurementFrequency Indication and Frequency Entry FM measurementFM Frequency Entry Menu Example LEV 65.0dBuV Then press 9 9 ./S 2 5 EnterFR104.80MHz LEV .dBuV FR104,80MHz LEV¯¯¯.¯dBuV Level MeasurementFr104.80MHz LEV 86.5dBuV LEV-RANGE2 FM SAT Spectrum Spectrum MeasurementTV Spectrum SAT-FullTV Spectrum Menu TV-Full FM SpectrumVHF UHF TV-NarrowCustomer Service MaintenanceChanging the Battery +14.1 dB Signal-to-Noise-RatioTechnical Appendix Instruction Set for 9xx Kathrein Matrix Production Run DiSEqC Commands for Kathrein MatricesInstruction Set for EXR 20 Kathrein Matrix Instruction Set for EXR 22 Kathrein MatrixVRF-CCIR URF-CCIR Channel TablesVHF UHF III Technical Appendix Technical Appendix Technical Appendix Technical Appendix 936.2642/D/1005/ZWT Subject to technical modifications