SAT measurement
Data Byte Menu
À
A corresponding data byte need not be sent to a command byte unless required by the command byte data byte(s). You can see this from the preceding command byte table. Please learn from the data sheets of the respective instruments which data byte is to be sent to the particular command byte.
Orbit- | Switch setting | Switch setting LNB | Data byte |
position | H/V |
|
|
|
|
|
|
| V | Lo | F0 |
|
|
|
|
1 | V | Hi | F1 |
|
|
|
|
| H | Lo | F2 |
|
|
|
|
| H | Hi | F3 |
|
|
|
|
| V | Lo | F4 |
|
|
|
|
2 | V | Hi | F5 |
|
|
|
|
| H | Lo | F6 |
|
|
|
|
| H | Hi | F7 |
| V | Lo | F8 |
|
|
|
|
3 | V | Hi | F9 |
| H | Lo | FA |
| H | Hi | FB |
| V | Lo | FC |
4 | V | Hi | FD |
| H | Lo | FE |
| H | Hi | FF |
|
|
|
|
Simple Tone Burst DiSEqC™
Simple DiSEqC™ Menu
À
A simplified version of the DiSEqC™ control is the Simple Tone Burst DiSEqC™ procedure. Simple DiSEqC™ allows two different switching states: Tone Burst and Data Burst.
[2ndF] | Call- up |
[9] [9] | |
[0] | Tone Burst entry |
[1] | Data Burst entry |
[ENTER] | Sending of command string |
[2ndF] [2ndF] | Exit |
31