Toshiba KV-7960A instruction manual VCR Display

Page 10

INTRODUCTION

VCR DISPLAY

PREPARATION

1

2

3

4

5

 

COUNT.

ALARM

ALARM

PW.FAIL

H

 

M

M

 

 

 

PLAY

REC

 

 

DEW

SP

 

 

 

 

 

 

 

 

 

 

 

 

TIMER

EP

 

 

6

7

 

8 9

10

 

1Cassette indicator

Lights when a tape is inserted.

2Counter memory indicator

Lights when the counter memory is selected.

3Alarm Memory indicator

7Counter/Alarm Counter/Remaining Tape/Error Mes- sage indicator

Press the ALARM button to display the alarm counter.

Press the ALARM button again to return to display the counter.

Press the TAPE REMAIN button to display the remaining tape time.

When an abnormality occurs during operation, the error code is displayed.

E-1: Abnormality on reel rotation during tape running.

E-3: Abnormality on cylinder rotation during recording and playback.

E-4: Abnormality on tape loading mechanism.

E-5: Video tape is cut.

E-6: Head clog.

E-8: Dew condensation.

RECORDING

OPERATION

 

 

PLAYBACK

OPERATION

 

 

NOTICE

Lights when the alarm memory is selected.

4Alarm indicator

Lights during alarm recording and blinks after an alarm recording cycle is completed.

5PW.FAIL (Power Failure) indicator Blinks when a power failure occurs.

6TAPE operation indicator

Displays as shown below, depending on operational modes.

Playback

 

 

 

 

Other than playback

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Playback

 

PLAY

 

Record

 

 

REC

 

 

 

 

 

 

y

 

 

 

y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Still

 

PLAY

 

Pause

 

 

REC

 

 

 

 

j

 

j

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slow

 

PLAY

 

Time-lapse

 

 

REC

 

 

 

 

 

jy

 

 

jy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field Advance

 

PLAY

 

Fast Forward

 

 

e

 

 

 

jy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reverse

 

 

 

 

 

 

 

 

 

 

 

 

PLAY

 

Rewind

b

 

Playback

 

 

 

 

a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Forward

 

 

 

 

 

 

 

 

 

 

 

 

PLAY

 

 

 

 

 

 

 

Picture Search

 

 

 

 

e

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reverse

 

 

 

 

 

 

 

 

 

 

PLAY

 

 

 

 

 

 

 

Picture Search

 

b

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reverse

 

 

 

 

 

 

 

 

 

PLAY

 

 

 

 

 

 

 

Field Advance

 

a j

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8Dew indicator

Blinks when the dew condensation has developed inside the VCR.

9Timer indicator

Lights when the timer recording button is pressed and the VCR has been set in timer record mode.

10Record/Playback Time indicator Displays record/playback time mode.

9

Image 10
Contents Instruction Manual Important Precautions Please ReadPower-Cord Protection Important Safety InstructionsPower Sources Radiators, heat registers, stovesWhen the power-supply cord or plug is damaged AccessoriesPower Lines To restore the product to its normal operationFeatures Table of ContentsInstructions in Brief Front PanelCassette Compartment Time Mode / SET + buttonsTape Remain button Display buttonRear Panel Installation Word on the Exclusive 3N-100AAS Battery PackSpecification of Battery RemovalVCR Display Press to start play back 1PAUSE/STILL buttonREW button FF buttonConnections Connection with a Video CameraTo REC TRIGG. OUT Typical Connection with the Sequential SwitcherVideo OutputContents of Screen Display Alarm Recall Screen Setting the Clock OperationMonitor screen VCR display ON-SCREEN FunctionsDate-Time Display On-Screen PositionDisplay Screen Changes to the alarm number Alarm numberIs pressed. When an alarm is This function enables to indicate and record informationCounter Displays Alarm MemoryCounter Memory Tape Remain Error MessageCode Number Condition of Abnormality HOW to Operate 24 Hour Virtual Real Time Mode Setting the RECORDING/PLAYBACK TimeA18 20s Fields/s Possible Continuous Virtual Real Time mode Loading a cassette Loading and Unloading a Video CassetteUnloading a Cassette Recording Camera and monitor TV Not been removedRestart Recording Setting the Restart RecordingRestart REC Daily Timer Recording Timer RecordingSetting the Timer Program Program ScreenTo cancel the timer recording, press the Power button or Press the Timer buttonPower goes off and the Timer display lights VCR display Button twice to erasePress the Shift ButtonGRAM.to blink PRO Weekly Timer RecordingPress the Shift Button to blink the MO1 start time FR2 Overlapping ProgramsExample DLYAlarm Recall Display Alarm RecordingOperation at Alarm Input Event RecordingConnecting the Alarm Terminals Cont Setting the Alarm RecordingDisplay Recording time ManualOperation of One-shot Recording Connecting the One-shot terminalONE-SHOT Recording Display Recording fieldsTo release the One-shot Recording mode Operation After Tape END Detection How to Set to Stop at End of TapeSetting contents Buzzer Screen display Counter display Display Operation after detection of tape endPress the + or SET How to Set to Auto Rewind at End of TapeAlarm recording does not operate during auto-rewind Menu ScreenHow to Set to Repeat Record at End of Tape ButtonREC. to select REW →Timing for Camera Switching Recording with the Sequential SwitcherConnection with the Sequential Switcher C D a B C DButton to set the REC REC Trigger Output Selection in the Alarm RecordingRecord mode Trigger SELRecording time mode Time mode for playback Tracking AdjustmentPlayback Picture Using the Shuttle DialREW Stop Search PlayPlayback in Various Modes Search Operation Time Date SearchPress the SET button to Set the Minute to Alarm Search Still picture mode Press the Play buttonSignal Levels of INPUT/OUTPUT Terminals Input/Output Terminal Signal level Additional remarksA2-hour mode 10want to set to Check the playback picture recorded in A2 hour modePress Time Mode button to go to Daily and Periodic InspectionRequest for Periodic Checks Recording Usage frequency Time modeSteps to Take after Daily Checks Tape Usage FrequencyDew Condensation Function/Operation Before Calling Service PersonnelInstallation RecordingPlayback Other mattersAccessories SpecificationsConnector section Warranty card Dew caution sheetToshiba America C.P.INC