Bosch Appliances Divar -Digital Versatile Recorder Primary connections, Optional connections

Page 15

Divar Installation Manual Quick install

EN 2-3

Primary connections

1.Connect the cameras to the BNC loop-through camera inputs (automatically terminated).

2.Connect monitor A to the BNC output MON A.

Optional connections

3.Connect monitor B to the BNC output MON B.

4.Connect up to 16 (alarm) inputs via the supplied 25-pin D-type connector board.

5.Connect up to 4 alarm output relays via the supplied 25-pin D-type connector board.

6.Connect a keyboard unit to the KBD IN socket.

7.Connect a pan/tilt/zoom control unit via the supplied 15-pole D-type connector board

8.Connect to your network via the Ethernet port or use the RS232 connector to connect directly to a PC serial port.

9.Connect an external storage unit via the narrow 50-pin high density SCSI-2 port. (For Divars with an internal DVD writer: Do not remove the supplied terminator from the SCSI connector unless you connect a disk array! )

Powering up

10.Switch on all connected equipment.

11.Connect the power cord to the unit.

First-time use

The unit starts with a multiscreen display. The Quick install menu opens the first time you use the unit. Fill in these basic settings to get the unit operational. Select the Install item to save your settings and close the menu. When you close the Quick install menu, the unit begins recording automatically.

To open the Quick install menu at any other time:

1.Press the ALT key to enter the alternate function mode.

>The ALT indicator lights.

2.Press the menu key .

>The main menu appears full-screen on monitor A.

Select the System settings menu and then the Quick install submenu.

Navigating

Use the arrow keys to move through a menu or list.

Use the select key to select a submenu or item.

Use the escape key to go back or to switch off the menu.

Bosch Security Systems

Image 15
Contents Divar Digital Versatile Recorder Page Chapters Digital Versatile Recorder Installation manualOperating instructions Hardware setupQuick install IntroductionUsing the Configuration Tool Menu default valuesTechnical specifications Safety Precautions Divar Installation Manual Reference Definition of termsIcons shown on the screen Digital video recorder for security applications IntroductionVersions FeaturesUnpacking Package contentsInstallation environment On-screen helpDVD writer Associated equipmentQuick install Quick connection First-time use Powering upPrimary connections Optional connectionsQuick Install Menu DAY Period Enter a Divar name to be used in the network Operating instructions Front panel controls Divar BilinxDivar Bilinx with internal DVD writer Keys IndicatorsPrimary functions Alternate functions Monitor B Viewing picturesViewing Monitor aCameo assignment MultiscreenFull-screen SequencePress the ALT key to return the keys to normal operation ZoomTo zoom in on a camera picture Press the ALT key Press the zoom keyLive mode Playback modeLive, playback and search modes Protecting or archiving a video recording Search modeSearch Results Background events Triggers and alarmsAlarms Alarms and TriggersIf a motion detection signal causes an alarm Alarm inputsMotion alarm If an input causes an alarmIf the loss of a video signal causes an alarm Video loss alarmMultiple alarms Disk-full alarmHardware setup Mounting SpecificationRack mounting Camera connectionsRS232 console port socket SpecificationsMonitor connections Console port connectionKeyboard out RJ11 socket KBD OUT Keyboard connectionsDivar connection Keyboard In RJ11 socket KBDNetwork configuration Ethernet connectionLAN RJ-45 Ethernet socket Control port 15-pole D-type socket Control portExternal I/O 25-pole D-type socket Connecting the InputsConnecting the Alarm Outputs External I/O connectionScsi connection Connector unless you connect a disk arrayPower supply socket Power SupplyTesting MaintenanceDivar Installation Manual Hardware setup Menu system Accessing the menu from the unit Setting the dynamic characteristicsOverview of the menu system Main Menu History Local Archiving Authenticity Check TIME/DATE Adjust Contrast submenu Bosch Security SystemsExit Menu on Alarms item to Yes System Settings Playback Setup History LOG Setup Administrator Profiles Profile Override Output handling Divar Installation Manual Menu system Using Configuration ToolSystem requirements Installing the Configuration ToolStarting the Configuration Tool Getting startedTo modify the Divar list How to LogLogin Menu structure differencesMaximum number of users Overview button Settings buttonUsing the Menu tree Introducing the main windowLogout button Service buttonUsing the control buttons Help buttonPrevious / Next Refining settingsRefresh Undo / RedoDivar Installation Manual Using the Configuration Tool Menu default values YYYY-MM-DD ATM/POS Divar Installation Manual Menu default values Dhcp Administrator Profiles Profile manager Divar Installation Manual Menu default values Technical specifications Electrical Accessories Optional MechanicalEnvironmental Divar Installation Manual Technical specifications Page Bosch Security Systems B.V