Divar Installation Manual Menu system
EN
>>>Disk Full Alarm Setup
•Set the percentage of used disk space at which the
•Set the time in minutes before the disk is full at which a
•Select the number of the output relay that is activated when a disk- full alarm is generated.
•Enable the beeper to activate it when a
>>PLAYBACK SETUP
Use the Playback Setup list to block the playback of recordings from particular cameras after a specified period of time.
•Choose from No Block, 1 to 7 days, 14 days, 21 days, 28 days or 31 days. When the specified time has elapsed, the recordings of that camera from before that time cannot be played back.
>>EVENT SETUP
Use the Event Setup menu to specify the display behavior for an input, detected motion or video loss.
•Set the Alarm Dwell Time to select the period during which the output relay and the beeper remain active after activation.
•Set the Trigger Dwell Time to select the period during which the triggered view mode is displayed after activation.
•The value Follows activates the beeper and relay or view, only as long as the event is present.
>>>Input Setup
•To restore the default input settings select the Clear Input Settings item.
•Select the Display Monitor submenu to choose the view mode and cameras to be displayed when an input is activated.
•Select the number of the output relay to be activated when any alarm input is activated.
•Enable the beeper to activate it when an alarm input is activated.
•Select the Input Name submenu to assign a name to each of the 16 Divar inputs.
•If an alarm panel is connected to the RS232 port and enabled, select the Alarm Input Mapping submenu to associate alarms from the alarm panel with the 16 Divar inputs.
•Select the
Display mon A
•Select the input number (1 to 16) for which you wish to set the view mode.
•If you have controllable cameras, set a camera number and a pre- position number. The specified camera goes to this position when the numbered input is activated.
•Select a view mode. Only view modes that are enabled can be selected.
•If you have selected the
Display mon B
•Select the input number (1 to 16) for which you wish to set the view mode.
•If you have controllable cameras, set a camera number and a pre- position number. The specified camera goes to this position when the numbered input is activated.
•Select up to four cameras to be displayed in sequence.
Alarm Input Mapping
•Only shown if alarm panel is connected and enabled.
•The control console type is displayed.
•For each of the 16 alarm inputs, select either the physical Divar input (the physical input is automattically mapped to its corresponding alarm input number) or an input from the control console (Alarm Panel 1 to Alarm Panel 238).
Bosch Security Systems