Bosch Appliances Divar -Digital Versatile Recorder installation instructions Electrical

Page 76

Divar Installation Manual Technical specifications

EN 8-2

Electrical

Voltage and Power

All models100-240 VAC; 0.7-0.3A, 50/60Hz

Video

Video standard:

PAL/NTSC auto-detect

Resolution:

720 x 576 PAL - 720 x 484 NTSC

AGC:

Automatic adjustment or manual adjustment of gain for

 

each video input

Digital Zoom:

2 or 4 times

Compression:

WAVELET

Inputs:

composite video 0.5-2Vpp, 75 ohm, automatic

 

termination

Outputs:

1Vpp, 75 ohm, sync 0.3 V ± 10%

Alarm Handling:

Inputs:

16 configurable NO/NC

 

max. input voltage 40 VDC

Outputs:

4 relay outputs, configurable NO/NC

 

max. rated 30 VAC - 40 VDC - 0.5A continuous -10VA

Control

RS232:

Output signals according EIA/TIA-232-F

 

max. input voltage ±25V

Keyboard input:

Conform RS485, max. signal voltage ±12V,

 

supply 11V-12.6V at max. 400mA

Keyboard output:

Conform RS485, max. signal voltage ±12V

Bi-Phase:

Impedance 128 ohm, max.

 

overvoltage protection ±40V,

 

max. cable length 1.5km

Bilinx:

Bilinx-enabled controllable cameras via BNC camera

 

connectors (Divar Bilinx version only).

Connectors

Video inputs:

6, 9 or 16 looping BNC, auto-terminating

Ethernet:

RJ45 shielded, 10/100 BaseT according IEEE802.3

Monitors:

BNC (2), MON-A multiscreen, MON-B spot/alarm

Alarm connectors:

Screw terminal input

Bi-Phase:

Screw terminal output

RS232:

DB9 male

Keyboard input:

RJ11 (6-pin)

Keyboard output:

RJ11 (4-pin), conform RS485, 30 units max.

SCSI:

HD 50-pin, max. 6 connected ultra SCSI devices,

 

20Mbytes/sec

Storage

Hard Disks:

80GB -160GB - 320GB - 600GB

 

Expandable via SCSI-2 HD50-pin, up to 6 external

 

storage arrays (17TB max.): type DVAD or DVAS.

File sizes:

High quality: 40Kb

 

Medium quality: 24Kb

 

Standard quality: 16Kb

Record Rate (IPS):

NTSC: 60 total, configurable per camera: 30, 15, 10,

 

7.5, 6, 5, 4, 3, 2, 1, ½, 1/5, 1/10, 0, Never

 

PAL: 50 total, configurable per camera: 25, 12.5, 8, 6,

 

5, 4, 3, 2, 1, ½, 1/5, 1/10, 0, Never

Recording Resolution:

720 x 288 PAL - 720 x 242 NTSC

Bosch Security Systems

Image 76
Contents Divar Digital Versatile Recorder Page Digital Versatile Recorder Installation manual ChaptersHardware setup Quick installIntroduction Operating instructionsMenu default values Using the Configuration ToolTechnical specifications Safety Precautions Divar Installation Manual Definition of terms ReferenceIcons shown on the screen Introduction Digital video recorder for security applicationsFeatures VersionsPackage contents Installation environmentOn-screen help UnpackingAssociated equipment DVD writerQuick install Quick connection Powering up Primary connectionsOptional connections First-time useQuick Install Menu DAY Period Enter a Divar name to be used in the network Operating instructions Divar Bilinx Front panel controlsDivar Bilinx with internal DVD writer Indicators KeysPrimary functions Alternate functions Viewing pictures ViewingMonitor a Monitor BMultiscreen Full-screenSequence Cameo assignmentZoom To zoom in on a camera picture Press the ALT keyPress the zoom key Press the ALT key to return the keys to normal operationPlayback mode Live modeLive, playback and search modes Search mode Protecting or archiving a video recordingSearch Results Triggers and alarms AlarmsAlarms and Triggers Background eventsAlarm inputs Motion alarmIf an input causes an alarm If a motion detection signal causes an alarmVideo loss alarm Multiple alarmsDisk-full alarm If the loss of a video signal causes an alarmHardware setup Specification Rack mountingCamera connections MountingSpecifications Monitor connectionsConsole port connection RS232 console port socketKeyboard connections Divar connectionKeyboard In RJ11 socket KBD Keyboard out RJ11 socket KBD OUTEthernet connection Network configurationLAN RJ-45 Ethernet socket Control port Control port 15-pole D-type socketConnecting the Inputs Connecting the Alarm OutputsExternal I/O connection External I/O 25-pole D-type socketConnector unless you connect a disk array Scsi connectionPower Supply TestingMaintenance Power supply socketDivar Installation Manual Hardware setup Menu system Setting the dynamic characteristics Accessing the menu from the unitOverview of the menu system Main Menu History Local Archiving Authenticity Check Adjust Contrast submenu Bosch Security Systems TIME/DATEExit Menu on Alarms item to Yes System Settings Playback Setup History LOG Setup Administrator Profiles Profile Override Output handling Divar Installation Manual Menu system Configuration Tool UsingInstalling the Configuration Tool Starting the Configuration ToolGetting started System requirementsHow to Log To modify the Divar listMenu structure differences LoginMaximum number of users Settings button Using the Menu treeIntroducing the main window Overview buttonService button Using the control buttonsHelp button Logout buttonRefining settings RefreshUndo / Redo Previous / NextDivar Installation Manual Using the Configuration Tool Menu default values YYYY-MM-DD ATM/POS Divar Installation Manual Menu default values Dhcp Administrator Profiles Profile manager Divar Installation Manual Menu default values Technical specifications Electrical Mechanical Accessories OptionalEnvironmental Divar Installation Manual Technical specifications Page Bosch Security Systems B.V