Bosch Appliances Divar -Digital Versatile Recorder installation instructions Time/Date

Page 49

Divar Installation Manual Menu system

EN 5-7

TIME/DATE >

MAIN MENU

TIME/DATE

TIME ZONE

GMT

+01:00 WEST-EUROPE

TIME FORMAT

 

24 HOUR

TIME

 

14:00:17

DATE FORMAT

 

YYYY-MM-DD

DATE

 

2002-06-19

SYNCHRONIZE

 

>

DAYLIGHT SAVING

 

YES

START DATE/TIME

 

LAST SUN MAR 02:00

END DATE/TIME

 

LAST SUN SEP 03:00

OFFSET

 

01:00

 

 

 

Select a time zone from the list. (Daylight saving time is adjusted accordingly.)

Fill in the actual time and date.

Select either a 12-hour or a 24-hour clock format.

Select from three date formats which show either the month (MM), the day (DD) or the year (YYYY) first.

Set Daylight Saving to Yes to enable it. Fill in the day, month and time of both change-overs and the offset if it differs from the information associated with your time zone.

>>SYNCHRONIZE

Use the Synchronize function to set the time of the unit from the time of the network. (Synchronize only works if the Divar time is within 7½ minutes of the server time.) Fill in the IP address of the network time server.

The time and date of all other connected units are automatically synchronized every hour from the time and date of the unit with DVR ID 1.

VIEW SETTINGS >

The View Settings menu allows you to set up the display of the individual cameras. You can also set the sequence in which the cameras are displayed and the duration. Use the Configure Monitors submenu to set up the monitor displays.

MAIN MENU

VIEW SETTINGS

CAMERA SETUP

>

SEQUENCES

>

CONFIGURE MONITORS

>

>> CAMERA SETUP

 

Use the Camera Setup menu to access the submenus for setting the camera

 

names, for locking cameras and for controlling cameras.

 

>>>Camera name

Select a camera by pressing a camera key on the unit. The number of the camera is the number of the connector at the rear of the unit to which it is connected.

Enter a name for the selected camera. The name can be up to 16 characters long.

>>>Camera lock-out

Locked cameras are not visible during normal use.

Place a check mark under the number of the camera you wish to lock or press a camera key on the unit to switch the lock on or off.

Select the Set Password submenu and fill in a 4-digit password to restrict access to the camera lock-out menu.

>>>Camera control

Set the Auto Camera Contrast to On to let the system automatically adjust the contrast for each camera.

If you set the Auto Camera Contrast to Off, you can access the

Adjust Contrast submenu.

Bosch Security Systems

Image 49
Contents Divar Digital Versatile Recorder Page Chapters Digital Versatile Recorder Installation manualQuick install Hardware setupIntroduction Operating instructionsMenu default values Using the Configuration ToolTechnical specifications Safety Precautions Divar Installation Manual Definition of terms ReferenceIcons shown on the screen Digital video recorder for security applications IntroductionVersions FeaturesInstallation environment Package contentsOn-screen help UnpackingDVD writer Associated equipmentQuick install Quick connection Primary connections Powering upOptional connections First-time useQuick Install Menu DAY Period Enter a Divar name to be used in the network Operating instructions Divar Bilinx Front panel controlsDivar Bilinx with internal DVD writer Keys IndicatorsPrimary functions Alternate functions Viewing Viewing picturesMonitor a Monitor BFull-screen MultiscreenSequence Cameo assignmentTo zoom in on a camera picture Press the ALT key ZoomPress the zoom key Press the ALT key to return the keys to normal operationPlayback mode Live modeLive, playback and search modes Protecting or archiving a video recording Search modeSearch Results Alarms Triggers and alarmsAlarms and Triggers Background eventsMotion alarm Alarm inputsIf an input causes an alarm If a motion detection signal causes an alarmMultiple alarms Video loss alarmDisk-full alarm If the loss of a video signal causes an alarmHardware setup Rack mounting SpecificationCamera connections MountingMonitor connections SpecificationsConsole port connection RS232 console port socketDivar connection Keyboard connectionsKeyboard In RJ11 socket KBD Keyboard out RJ11 socket KBD OUTEthernet connection Network configurationLAN RJ-45 Ethernet socket Control port 15-pole D-type socket Control portConnecting the Alarm Outputs Connecting the InputsExternal I/O connection External I/O 25-pole D-type socketScsi connection Connector unless you connect a disk arrayTesting Power SupplyMaintenance Power supply socketDivar Installation Manual Hardware setup Menu system Setting the dynamic characteristics Accessing the menu from the unitOverview of the menu system Main Menu History Local Archiving Authenticity Check TIME/DATE Adjust Contrast submenu Bosch Security SystemsExit Menu on Alarms item to Yes System Settings Playback Setup History LOG Setup Administrator Profiles Profile Override Output handling Divar Installation Manual Menu system Using Configuration ToolStarting the Configuration Tool Installing the Configuration ToolGetting started System requirementsTo modify the Divar list How to LogMenu structure differences LoginMaximum number of users Using the Menu tree Settings buttonIntroducing the main window Overview buttonUsing the control buttons Service buttonHelp button Logout buttonRefresh Refining settingsUndo / Redo Previous / NextDivar Installation Manual Using the Configuration Tool Menu default values YYYY-MM-DD ATM/POS Divar Installation Manual Menu default values Dhcp Administrator Profiles Profile manager Divar Installation Manual Menu default values Technical specifications Electrical Mechanical Accessories OptionalEnvironmental Divar Installation Manual Technical specifications Page Bosch Security Systems B.V