Bosch Appliances Divar -Digital Versatile Recorder Monitor connections, Console port connection

Page 35

Divar Installation Manual Hardware setup

EN 4-3

Monitor connections

Connect the unit to the monitors using 75-ohm video coaxial cables with BNC connectors. The unit provides a 1Vpp CVBS signal.

If the monitor has a loop-through connection and you are not using the loop- through output, then select the 75-ohm impedance setting on the monitor. If the monitor's loop-through output is connected to an additional device, the device's termination is set to 75 ohms and the monitor's termination is set to high impedance. (Note that this is not necessary on devices with automatic termination.)

Specifications

Output signal:

Composite video 1Vpp, 75 Ohm, Sync. 0.3Vpp ±10%

Resolution:

720 x 576 PAL, 720 X 484 NTSC

Connector type:

BNC

Console port connection

The serial RS232 console port connector is used to connect a PC to the unit for configuration or service purposes. Use a null-modem cable to connect the serial port of the PC to the unit. The Baud rate can be selected in the menu system.

The serial RS232 console port connector is also used to connect Bosch D9000 series control panels via an interface unit for Divar alarm activation. Alarm input mapping can be set up in the menu system.

Specification

Connector type:

9-pole D-type male connector

Maximum input voltage:

±25V

Communicaton protocol:

Output signals according EIA/TIA-232-F

RS232 console port socket

Signal Name:

Pin no.

Description

 

DCD_in

1

Carrier detection signal (not used).

 

 

 

RX

2

RS232 receive signal

 

 

 

TX

3

RS232 transmit signal

 

 

 

 

N/C

4

No Connection

 

 

 

 

 

System Ground

5

System Ground

 

 

 

 

 

N/C

6

No Connection

 

 

 

 

RTS

7

RS232 request to send signal

 

 

 

CTS

8

RS232 clear to send signal

 

 

 

 

N/C

9

No Connection

 

 

 

 

 

 

 

 

 

 

 

5

1

 

 

9

6

Panel view

Bosch Security Systems

Image 35
Contents Divar Digital Versatile Recorder Page Chapters Digital Versatile Recorder Installation manualOperating instructions Hardware setupQuick install IntroductionTechnical specifications Using the Configuration ToolMenu default values Safety Precautions Divar Installation Manual Icons shown on the screen ReferenceDefinition of terms Digital video recorder for security applications IntroductionVersions FeaturesUnpacking Package contentsInstallation environment On-screen helpDVD writer Associated equipmentQuick install Quick connection First-time use Powering upPrimary connections Optional connectionsQuick Install Menu DAY Period Enter a Divar name to be used in the network Operating instructions Divar Bilinx with internal DVD writer Front panel controlsDivar Bilinx Keys IndicatorsPrimary functions Alternate functions Monitor B Viewing picturesViewing Monitor aCameo assignment MultiscreenFull-screen SequencePress the ALT key to return the keys to normal operation ZoomTo zoom in on a camera picture Press the ALT key Press the zoom keyLive, playback and search modes Live modePlayback mode Protecting or archiving a video recording Search modeSearch Results Background events Triggers and alarmsAlarms Alarms and TriggersIf a motion detection signal causes an alarm Alarm inputsMotion alarm If an input causes an alarmIf the loss of a video signal causes an alarm Video loss alarmMultiple alarms Disk-full alarmHardware setup Mounting SpecificationRack mounting Camera connectionsRS232 console port socket SpecificationsMonitor connections Console port connectionKeyboard out RJ11 socket KBD OUT Keyboard connectionsDivar connection Keyboard In RJ11 socket KBDLAN RJ-45 Ethernet socket Network configurationEthernet connection Control port 15-pole D-type socket Control portExternal I/O 25-pole D-type socket Connecting the InputsConnecting the Alarm Outputs External I/O connectionScsi connection Connector unless you connect a disk arrayPower supply socket Power SupplyTesting MaintenanceDivar Installation Manual Hardware setup Menu system Overview of the menu system Accessing the menu from the unitSetting the dynamic characteristics Main Menu History Local Archiving Authenticity Check TIME/DATE Adjust Contrast submenu Bosch Security SystemsExit Menu on Alarms item to Yes System Settings Playback Setup History LOG Setup Administrator Profiles Profile Override Output handling Divar Installation Manual Menu system Using Configuration ToolSystem requirements Installing the Configuration ToolStarting the Configuration Tool Getting startedTo modify the Divar list How to LogMaximum number of users LoginMenu structure differences Overview button Settings buttonUsing the Menu tree Introducing the main windowLogout button Service buttonUsing the control buttons Help buttonPrevious / Next Refining settingsRefresh Undo / RedoDivar Installation Manual Using the Configuration Tool Menu default values YYYY-MM-DD ATM/POS Divar Installation Manual Menu default values Dhcp Administrator Profiles Profile manager Divar Installation Manual Menu default values Technical specifications Electrical Environmental Accessories OptionalMechanical Divar Installation Manual Technical specifications Page Bosch Security Systems B.V