Bosch Appliances Divar -Digital Versatile Recorder Exit Menu on Alarms item to Yes

Page 50

Divar Installation Manual Menu system

EN 5-8

Adjust contrast

Select a camera in the menu or press a camera key on the unit. The selected camera image appears.

Vary the manual gain value between -100 and +100 to adjust the contrast.

To set the default value (0), press the F1 key.

>>>Camera controllable

A check mark under a camera number indicates that it can be controlled remotely by the Control Center application.

Press a camera key on the unit to make a camera controllable or not.

By default all cameras are controllable.

>>>Bilinx cameras

Only shown if your Divar is a Divar Bilinx.

A check mark under a camera number indicates that Bilinx control is enabled.

Press a camera key on the unit to enabled or disable Bilinx control for that camera.

By default all cameras are enabled.

If Bilinx cameras are looped-through to multiple Divars, only one Divar is allowed to have Bilinx enabled!

>>SEQUENCES

The sequence in which cameras are displayed on monitor A and monitor B is set in the full screen list menu.

Set the length of time each image remains on the screen by filling in the dwell time value for each monitor.

Dwell time can vary from 1 to 60 seconds. The default value is 5 seconds.

>>>List Full screen monitor A

The sequence list shows the order in which the camera images are displayed in full screen mode (Control Center version 1 only).

Use the arrow keys to select a position in the list. Press a camera key on the unit to enter a camera number in the list.

Press F2 to clear the rest of the list.

Press F1 to restore all defaults. Connected cameras are then listed in ascending order.

>>>List Full screen monitor B

The sequence list shows the order in which the camera images are displayed in full screen mode (Control Center version 1 only).

Use the arrow keys to select a position in the list. Press a camera key on the unit to enter a camera number in the list.

Press F2 to clear the rest of the list.

Press F1 to restore all defaults. Connected cameras are then listed in ascending order.

>>CONFIGURE MONITORS

• To view camera names, and time and date on a monitor set these items to

On.

• Set Motion Display to On to draw attention to any motion that occurs in the designated zones.

• Select the position for the text (top or bottom and fine position +11/-11). Select text intensity. Select the border intensity of the cameos from four values.

• To automatically close the menu when an alarm or event occurs, set the

Exit Menu on Alarms item to Yes.

• The menu is closed after five minutes if you set the Menu Time-outto

On.

Bosch Security Systems

Image 50
Contents Divar Digital Versatile Recorder Page Digital Versatile Recorder Installation manual ChaptersIntroduction Hardware setupQuick install Operating instructionsTechnical specifications Using the Configuration ToolMenu default values Safety Precautions Divar Installation Manual Icons shown on the screen ReferenceDefinition of terms Introduction Digital video recorder for security applicationsFeatures VersionsOn-screen help Package contentsInstallation environment UnpackingAssociated equipment DVD writerQuick install Quick connection Optional connections Powering upPrimary connections First-time useQuick Install Menu DAY Period Enter a Divar name to be used in the network Operating instructions Divar Bilinx with internal DVD writer Front panel controlsDivar Bilinx Indicators KeysPrimary functions Alternate functions Monitor a Viewing picturesViewing Monitor BSequence MultiscreenFull-screen Cameo assignmentPress the zoom key ZoomTo zoom in on a camera picture Press the ALT key Press the ALT key to return the keys to normal operationLive, playback and search modes Live modePlayback mode Search mode Protecting or archiving a video recordingSearch Results Alarms and Triggers Triggers and alarmsAlarms Background eventsIf an input causes an alarm Alarm inputsMotion alarm If a motion detection signal causes an alarmDisk-full alarm Video loss alarmMultiple alarms If the loss of a video signal causes an alarmHardware setup Camera connections SpecificationRack mounting MountingConsole port connection SpecificationsMonitor connections RS232 console port socketKeyboard In RJ11 socket KBD Keyboard connectionsDivar connection Keyboard out RJ11 socket KBD OUTLAN RJ-45 Ethernet socket Network configurationEthernet connection Control port Control port 15-pole D-type socketExternal I/O connection Connecting the InputsConnecting the Alarm Outputs External I/O 25-pole D-type socketConnector unless you connect a disk array Scsi connectionMaintenance Power SupplyTesting Power supply socketDivar Installation Manual Hardware setup Menu system Overview of the menu system Accessing the menu from the unitSetting the dynamic characteristics Main Menu History Local Archiving Authenticity Check Adjust Contrast submenu Bosch Security Systems TIME/DATEExit Menu on Alarms item to Yes System Settings Playback Setup History LOG Setup Administrator Profiles Profile Override Output handling Divar Installation Manual Menu system Configuration Tool UsingGetting started Installing the Configuration ToolStarting the Configuration Tool System requirementsHow to Log To modify the Divar listMaximum number of users LoginMenu structure differences Introducing the main window Settings buttonUsing the Menu tree Overview buttonHelp button Service buttonUsing the control buttons Logout buttonUndo / Redo Refining settingsRefresh Previous / NextDivar Installation Manual Using the Configuration Tool Menu default values YYYY-MM-DD ATM/POS Divar Installation Manual Menu default values Dhcp Administrator Profiles Profile manager Divar Installation Manual Menu default values Technical specifications Electrical Environmental Accessories OptionalMechanical Divar Installation Manual Technical specifications Page Bosch Security Systems B.V