Motorola QIP7000 installation manual Agile OOB Tuner Hunting

Page 50

Diagnostics

B

Agile OOB Tuner Hunting

An OOB frequency can be selected manually by pressing the MENU button while in the OOB Status diagnostics screen. To exit this mode, press the MENU button a second time, or press the POWER button.

If the set-top is in the process of hunting for an OOB frequency, control of frequency selection is suspended, i.e. when the set-top is hunting, the ability to press the Menu button on the OOB status screen to display MAN FREQ is not available.

Summary of Manual Selection of the OOB Frequency (OSD Frequency Override in Hunted Mode)

The manual override frequency capability is only displayed if the box is not currently hunting and the operator presses the MENU key while OOB OSD diagnostics are displayed. The MAN Freq displays the LKC and allows the operator to select (via scroll up/down) a specific frequency to check if a valid OOB is on that specific frequency. The MAN Freq parameter is the OOB frequency selected in the frequency selection mode and displayed in MHz, with the specific values of 75.25, 104.20, 72.75, 92.25, 98.25, 107.25, 107.40, 110.25, 116.25, and 103.75.

1.When in the OOB Receiver Status Diagnostic, press the MENU button to enter the frequency selection mode. The frequency of the last known carrier is displayed on the Front Panel. The OSD displays a new “MAN FREQ” line at the bottom of the screen, which indicates the last known carrier frequency. At this point, if desired, the frequency change mode can be exited by pressing the MENU key a second time.

2.Use the UP/DOWN channel or cursor keys to scroll through all 10 frequencies until the desired new OOB frequency is found. The new frequency selections will appear on the Front Panel and on the “MAN FREQ” line of the OSD. When the last known frequency is selected, a DOT will appear in the middle-upper part of the Front Panel.

3.When the desired new frequency has been selected, press the SELECT key to start the search. The manual frequency search will last up to 40 seconds. As the set-top searches, the frequency being searched for will flash on the front panel. On the OSD, the “MAN FREQ” line of text will be cleared, the “HUNT MODE” will display “FIX” to indicate a search on a fixed frequency, and the “OOB FREQ” field will change to the frequency being searched for.

4.If the frequency is found with the proper EMM Provider ID, then the front panel will display the normal OOB receiver status. The OSD “LKC” field will change to display the new frequency.

5.If after 40 seconds the frequency search is not successful, the product will perform a warm reset.

6.TO ABORT A Search without waiting the 40 seconds, the POWER key can be pressed to cause an immediate warm reset.

Note: The front panel will display “hunt” after a cold reset from the front panel. This indicates that the product is in a Round Robin Hunt Mode. The message “hunt” will continue to be displayed until the proper stream is detected.

QIP7000 (P2) Series Hybrid QAM/IP HD Set-top Terminal • Installation Manual

42

574702-001 a

This document is uncontrolled pending incorporation in a Motorola CMS

Image 50
Contents QIP7000 P2 Series Page Safety and Compliance During Installation FCC Declaration of Conformity Contents D02 Operational Check for the Remote ControlD01 D03Figures 1Introduction QIP7232 Front and rear views Features TunersStandard Data Features Company From USA or Canada Outside USA or Canada Getting HelpCalling for Repairs Label Description Front PanelRear Panel Card Lable DescriptionSystem Overview PON OverviewFttp PON carries the following services Service DescriptionWhole Home IP Video CPE overview WAN LAN MoCAOOB Multi-Room DVR Multi room DVR networkInstallation Whole Home IP Video Network InstallationConnect to the ONT During the installationBefore You Begin After you finish connecting the components Checking the Home Coaxial Network TopologyIf you make any changes to the network, repeat steps 1 Video Connection OptionsMarginal MoCA network performance Connection TV Type DescriptionConnection Type Description Audio Connection OptionsClearing the Hard Drive Connecting to the ONT Connecting to the ONT with embedded MoCA MoCA technologyONT1000M Connections Key Name DescriptionConnecting the Home Router embedded MoCA ONT Connecting Homes with Multiple Existing Cable DropsConnecting the Home Router Installation Overview Determine if you are connecting to aCabling to an Hdtv for Video Cabling to an HdtvCabling to an Hdtv for Audio Cabling to an Hdtv for AudioCabling to an Hdtv and A/V Receiver for Video Cabling to an Hdtv and A/V Receiver Cabling to a Standard-Definition TV Cabling to a Standard Definition stereo TVCabling to a Standard-Definition TV, A/V Receiver and VCR Cabling to a Standard Definition TV, A/V Receiver and VCRPort type Description Data Device ConnectionsQIP7000 series front panel provides Feature Testing Procedure Operational Check for the Remote ControlOptimizing the High-Definition Settings Verifying the MoCA NetworkSetting Description Setting Description Graphics Overlaying the Video 4Diagnostics Using the DiagnosticsD01 General Status Example General Status display no error ROM ID General Status fields areField Description Front panel display for Purchase Status diagnostic D02 Purchase StatusPurchase Status fields are FieldFront panel display for the OOB diagnostic D03 Out-Of-Band OOB StatusOut-Of-Band Status fields are Agile OOB Tuner Hunting Front panel display for in-band diagnostic D04 In-Band StatusIn-Band Status fields are Carrier locked Carrier not locked PCR LockD05 Unit Address/Security Front panel display of a unit addressEMM EMM Separable SecurityUnit Address fields are SCC SccecmSeparable Security fields are SignD06 Current Channel Status Current Channel status fields are DigitalCIT CCIAPS DRMD07 Upstream Status Ethernet Return front panel displayEthernet Return fields are D08 Code Modules Front panel display for code modules Code Modules fields are D09 Memory Configuration NvramIEC958PCM D10 Audio/Video StatusAudio Spdif Unmuted BlackField Description D11 Interface/Port Status Page Interface Status fields are D12 User Setting Status Definition 480i format 720 x 480 pixels D13 DVR/Hard Drive Status DVR/Hard Drive Status fields are OSDD14 Application Specific Information Interactive Status fields are UnconfigD15 Interactive Status MacconnectWaitsoack InitwaitdcorcWaitlmack WaitlaorsoConnected Home Status fields are This diagnostic displays the MoCA network statusD16 Connected Home TX Data Rate Connected Home Link Status fields areD17 Key Pad / LED Test 5Troubleshooting Problem Possible SolutionProblem Possible Solution Off standby IP Network Issues Insufficient RF Network ThroughputUsing a diplexer to bypass a line amplifier Bypassing an Amplifier