Bosch Appliances XF Introduction, Digital video recorder for security applications, 2.1.1, 2.1.2

Page 13
Introduction

Divar XFIntroduction en 13

2

Introduction

2.1

Digital video recorder for security applications

 

The Divar XF is a video and audio recording system that records multiple camera and audio

 

signals while simultaneously providing live multiscreen viewing and playback.

 

The unit has comprehensive search and playback facilities for viewing stored video. Once

 

configured, all recording takes place in the background without requiring operator

 

intervention. Maximum recording rates of 30 (NTSC) and 25 (PAL) images per second, per

 

channel, are guaranteed. The recording rate and quality are selectable per camera. Up to four

 

internal hard disks can be used to provide various storage capacities for recording.

 

All models have extensive alarm handling functions and telemetry control. Alarm functions

 

include motion detection in user-definable areas of the image on any camera input.

 

The unit can be easily operated and programmed via the front panel control keys, mouse, and

 

the on-screen display menu system. Two monitor outputs provide full-screen, quad, and

 

multiscreen viewing. Connect a KBD (Intuikey) keyboard for PTZ control and to improve the

 

ease-of-use.

 

Looping auto-terminating video inputs and outputs, audio inputs and outputs, alarm inputs

 

and outputs, and remote control connectors are on the rear panel. Two VGA connectors

 

provide outputs for an A and a B monitor. CVBS and Y/C video outputs in either NTSC or PAL

 

are also provided. Monitor A displays full-screen or multiscreen digital pictures that can be

 

frozen and zoomed. Monitor B displays live full-screen or multiscreen pictures.

 

Use the Control Center PC-application via a network for live viewing, playback, and

 

configuration. Five simultaneous users can control multiple Divar XFs. The Divar XF includes

 

an authenticity check for both local and remote playback. A dedicated PC player is provided

 

for playback of secure video files. The PC-based Configuration Tool facilitates the installation

 

of the unit.

 

An SDK (software development kit) is available to integrate the Divar XF into third party

 

management software.

2.1.1

Versions

 

There are various Divar XF models; 8-channel and 16-channel with DVD burner option, each

 

with various storage capacities. Both 8-channel and 16-channel versions operate in exactly the

 

same way except that fewer camera, audio, and alarm inputs are present, and the number of

 

available multiscreen views differs.

 

Optionally, up to 8 IP cameras can be connected (in addition to the 8 or 16 analog input

 

channels).

2.1.2

Manuals

 

Four manuals are supplied:

 

– Installation manual - a detailed description for installers on how to install the product.

 

– Quick Installation guide - gives a brief overview on how to set up and install the product.

 

– Operation manual - a detailed description for end-users on how to operate the unit.

 

– Control Center and Archive Player operation manual - a detailed description for end-users

 

and administrators on how to set up and operate the Control Center and Archive Player

 

software.

2.1.3

Features

 

The Divar XF has the following features:

– 8 or 16 looped-through, auto-terminating camera inputs

– 8 or 16 audio inputs

Bosch Security Systems

Installation manual

F.01U.135.429 2.5 2009.08

Image 13
Contents Divar XF en Installation manualDigital Hybrid Recorder Page Safety Table of ContentsQuick install Hardware setupOperating instructions Advanced configuration menuUsing the Configuration Tool Technical specifications Menu default valuesImportant safety instructions 1SafetyImportant Notices Safety precautionsDANGER Coax grounding Class I Laser Product Rack-mount FCC and UL FCC & ICES Information U.S.A. and Canadian Models OnlyDisclaimer INFORMATIONS FCC ET ICESCopyright Bosch noticesTrademarks More informationIntroduction FeaturesDigital video recorder for security applications 2.1.1Unpacking Package contents2.1.4 On-screenhelpPower Supply Installation environmentAssociated equipment 2.3.116 en Introduction Installation manualDivar XF F.01U.135.429Connections Quick installPowering up Primary connectionsFirst-timeuse Quick install menu3.3.1 InternationalLanguage 3.3.2ScheduleTime zone Time format3.3.3Recording DVR name 3.3.4NetworkInstallation manual 22 en Quick installDivar XF F.01U.135.429Desktop installation Hardware setupRack mounting Mounting4.3.1 Hard disk installationMounting instructions Removing the front panelPlacing a hard disk 4.4Camera connectionsRemounting the front panel Audio connections SpecificationsMonitor connections 4.6.14.6.2CVBS Monitor streaming connectionSpecifications SpecificationsRS232 COM port connections Signal nameKeyboard connections Pin number4.10 SignalEthernet connection Termination4.11 4.12Biphase portRS485 port Signal nameSpecifications BIPHASESignal name Pin numberExternal alarm I/O connection USB connectorsConnecting the inputs Connecting the alarm outputsSignal name ALARM I/OPin number Description4.17Maintenance Power supply4.15 Malfunction relayFront panel controls Operating instructions5.1.1Keys Arrow keysOSD key Mouse Controls Indicators5.1.2 5.3.1 Viewing picturesMonitor A 5.3.2Full-screen MultiscreenSequence Cameo assignmentLive and playback Accessing playback functions5.4.1 Live modeOverview of the menu system ConfigurationSearch ExportAccess using the mouse Access using the front panel keysAccess using the Intuikey keyboard SearchDate/time search 5.6.15.6.2 Event searchSearch results Search criteria5.7Export Monitor settings 5.8Configuration5.8.1 Display optionsEvent display System informationSequence 5.9.1Status Video signalsVersion Info Storage statusSensors 5.9.2LogbookSensor name Lower limitEvent handling 5.10Logbook results Background eventsAcknowledging an alarm 5.10.1AlarmsIf a contact input causes an alarm Video loss alarmIf a motion detection signal causes an event If the loss of a video signal causes an alarmLeft tabs 6Advanced configuration menuTop tabs International6.1.1Language 6.1International54 en Advanced configuration menu Installation manual6.1.3 6.1.2Time/dateTime Server Video & Audio Enable video input6.2.1 Channels 1 to 8 or 1 to6.2.2Channels 9 to 16 or 17 to Enable audio inputContrast IP cameraSchedule Setting the dynamic characteristics6.3.1 6.3.2Schedule6.3.3Exceptions 6.4Recording6.4.2Contact 6.4.1Normal6.4.3Motion 6.4.4Copy6.5Contacts No override default6.5.1 6.5.26.6Motion Alarm dwell time Auto acknowledge alarms6.7Event 6.7.1GeneralActions when entering this profile Sound beeper on alarm6.7.2Contact 6.7.3Motion6.8Network 6.8.1Setup6.7.5Copy IP Range 6.8.26.8.3 Monitor Streaming6.9.3Service 6.9.2Settings6.10.2Administrator 6.9Storage6.11 ServiceSystem 6.10.36.11.4Logging Log contacts -Log motion -Log remote accessAdvanced configuration menu en Installation manualInstallation manual 70 en Advanced configuration menuDivar XF F.01U.135.429How to log on Using the Configuration ToolInstalling the Configuration Tool Starting the Configuration ToolTo modify the Divar XF list 7.2.1 7.3Introducing the main windowMenu structure differences Log onClick Settings Settings buttonUsing the Menu tree 7.3.1Service button 7.4Using the control buttonsClick Service Refining settingsRefresh Factory Defaults76 en Using the Configuration Tool Installation manualQuick install menu defaults Menu default valuesSetting Default valueConfiguration menu defaults Monitor view settings defaultsSetting Default valueDefault value SettingReset NavigationDefault value SettingReset NavigationDefault value SettingReset NavigationInstallation manual 82 en Menu default valuesDivar XF F.01U.135.429Voltage and Power Technical specificationsAlarm Handling ElectricalStorage ConnectorsAccessories Optional Electromagnetic and Safety9.1.1 MechanicalVideo bitrates bps 9.1.5Page Robert-Koch-Straße100 D-85521Ottobrunn Bosch Security SystemsGermany Telefon
Related manuals