Bosch Appliances XF Multiscreen, Full-screen, Sequence, Cameo assignment, Freeze image

Page 39
Multiscreen

Divar XF

Operating instructions en 39

 

 

Multiscreen

To view different multiscreen displays on monitor A or B:

1.Press the multiscreen Full-screen key.

A multiscreen display of camera pictures appears on the active monitor.

The camera keys of the selected cameras light (green).

2.Press the multiscreen Sequence key again to go to the next programmed multiscreen view.

If you continue to press the multiscreen Cameo assignment key, the unit cycles through all enabled multiscreen views.

Full-screen

To view a full-screen shot of a camera:

1.Press a camera key.

A full-screen shot of the analog camera you selected appears.

The camera key of the selected analog camera lights (green).

Press the camera key again to display the linked IP camera.

The camera key of the selected IP camera lights (orange).

2.While in multiscreen mode, press enter Freeze imageManual background to view the active cameo in full-screen.

Note:

IP camera numbering starts at 9 on an 8-channel model and at 17 on a 16-channel model. So on a 16-channel unit with IP cameras, camera key 1 selects analog camera 1 and IP camera 17.

Sequence

To view a sequence of live camera pictures of several cameras:

1.Press the sequence Manual background key.

A sequence of camera pictures appears, each for a pre-programmed dwell time.

2.Press the sequence Manual background key to stop sequencing.

Zooming, pressing the multiscreen key, or selecting a single camera also stops sequencing.

Cameo assignment

Assigning cameras to cameos in a multiscreen view:

1.Use the arrow keys to select a cameo.

2.Press and hold a camera key to display and assign that camera’s picture in the active cameo.

3.Alternatively, right click a cameo with the mouse and choose a video input from the context menu.

The cameo assignment that you make is used in playback mode as well as in live mode.

Freeze image

Freezing a camera shot on monitor A:

1.Press the freeze Manual background key to freeze the picture in the active cameo.

2.Press the freeze Manual background key again to return to live viewing.

Alternatively, right click and select Freeze or Unfreeze from the context menu using the mouse.

If you are viewing a camera picture in full-screen mode, then this picture is frozen. The zoom function can be used on a frozen picture. If you change viewing mode, any frozen pictures are released.

Bosch Security Systems

Installation manual

F.01U.135.429 2.5 2009.08

Image 39
Contents en Installation manual Divar XFDigital Hybrid Recorder Page Hardware setup Table of ContentsSafety Quick installOperating instructions Advanced configuration menuUsing the Configuration Tool Technical specifications Menu default valuesImportant safety instructions 1SafetySafety precautions Important NoticesDANGER Coax grounding Class I Laser ProductU.S.A. and Canadian Models Only FCC and ULRack-mount FCC & ICES InformationDisclaimer INFORMATIONS FCC ET ICESMore information Bosch noticesCopyright Trademarks2.1.1 FeaturesIntroduction Digital video recorder for security applicationsOn-screenhelp Package contentsUnpacking 2.1.42.3.1 Installation environmentPower Supply Associated equipmentF.01U.135.429 Installation manual16 en Introduction Divar XFPrimary connections Quick installConnections Powering upInternational Quick install menuFirst-timeuse 3.3.1Time format 3.3.2ScheduleLanguage Time zone3.3.3Recording DVR name 3.3.4NetworkF.01U.135.429 22 en Quick installInstallation manual Divar XFMounting Hardware setupDesktop installation Rack mountingRemoving the front panel Hard disk installation4.3.1 Mounting instructions4.4Camera connections Placing a hard diskRemounting the front panel 4.6.1 SpecificationsAudio connections Monitor connectionsSpecifications Monitor streaming connection4.6.2CVBS SpecificationsPin number Signal nameRS232 COM port connections Keyboard connectionsTermination Signal4.10 Ethernet connectionSignal name 4.12Biphase port4.11 RS485 portPin number BIPHASESpecifications Signal nameConnecting the alarm outputs USB connectorsExternal alarm I/O connection Connecting the inputsDescription ALARM I/OSignal name Pin numberMalfunction relay Power supply4.17Maintenance 4.15Arrow keys Operating instructionsFront panel controls 5.1.1Keys OSD key Indicators Mouse Controls5.1.2 5.3.2 Viewing pictures5.3.1 Monitor ACameo assignment MultiscreenFull-screen SequenceLive mode Accessing playback functionsLive and playback 5.4.1Export ConfigurationOverview of the menu system SearchSearch Access using the front panel keysAccess using the mouse Access using the Intuikey keyboardEvent search 5.6.1Date/time search 5.6.2Search results Search criteria5.7Export Display options 5.8ConfigurationMonitor settings 5.8.1System information Event displaySequence Storage status Video signals5.9.1Status Version InfoLower limit 5.9.2LogbookSensors Sensor nameBackground events 5.10Event handling Logbook resultsAcknowledging an alarm 5.10.1AlarmsIf the loss of a video signal causes an alarm Video loss alarmIf a contact input causes an alarm If a motion detection signal causes an eventInternational 6Advanced configuration menuLeft tabs Top tabsInstallation manual 6.1International6.1.1Language 54 en Advanced configuration menu6.1.2Time/date 6.1.3Time Server Channels 1 to 8 or 1 to Enable video inputVideo & Audio 6.2.1IP camera Enable audio input6.2.2Channels 9 to 16 or 17 to Contrast6.3.2Schedule Setting the dynamic characteristicsSchedule 6.3.16.3.3Exceptions 6.4Recording6.4.4Copy 6.4.1Normal6.4.2Contact 6.4.3Motion6.5.2 No override default6.5Contacts 6.5.16.6Motion 6.7.1General Auto acknowledge alarmsAlarm dwell time 6.7Event6.7.3Motion Sound beeper on alarmActions when entering this profile 6.7.2Contact6.8.1Setup 6.8Network6.7.5Copy Monitor Streaming 6.8.2IP Range 6.8.36.9Storage 6.9.2Settings6.9.3Service 6.10.2Administrator6.10.3 Service6.11 SystemInstallation manual Log contacts -Log motion -Log remote access6.11.4Logging Advanced configuration menu enF.01U.135.429 70 en Advanced configuration menuInstallation manual Divar XFStarting the Configuration Tool Using the Configuration ToolHow to log on Installing the Configuration ToolTo modify the Divar XF list Log on 7.3Introducing the main window7.2.1 Menu structure differences7.3.1 Settings buttonClick Settings Using the Menu treeRefining settings 7.4Using the control buttonsService button Click ServiceInstallation manual Factory DefaultsRefresh 76 en Using the Configuration ToolDefault value Menu default valuesQuick install menu defaults SettingDefault value Monitor view settings defaultsConfiguration menu defaults SettingNavigation SettingDefault value ResetNavigation SettingDefault value ResetNavigation SettingDefault value ResetF.01U.135.429 82 en Menu default valuesInstallation manual Divar XFElectrical Technical specificationsVoltage and Power Alarm HandlingStorage ConnectorsMechanical Electromagnetic and SafetyAccessories Optional 9.1.1Video bitrates bps 9.1.5Page Telefon Bosch Security SystemsRobert-Koch-Straße100 D-85521Ottobrunn Germany