Divar XF | Operating instructions en 49 |
|
|
Alarm recording at input - displays which inputs are in alarm recording mode Motion recording at input - displays which inputs are in motion recording mode
Current recording status - displays video and audio recording status and mode for each input
Sensors
Displays actual temperature and voltage sensor values. If temperature levels are outside of the normal range, the displayed values are yellow. If this occurs, check that the ambient temperature is within the recommended specifications and that there is proper air ventilation. If the temperature reaches a critical level, the unit automatically shuts down. To restart the unit, disconnect the power cord, wait for at least 30 seconds, and then reconnect the power cord.
Sensor name | Lower limit | Upper limit |
|
|
|
Processor | 5 °C / 41 °F | 100 °C / 212 °F |
|
|
|
Air inlet | 5 °C / 41 °F | 45 °C / 113 °F |
|
|
|
Air outlet | 5 °C / 41 °F | 55 °C / 131 °F |
|
|
|
Hard disk #1 | 5 °C / 41 °F | 55 °C / 131 °F |
|
|
|
Hard disk #2 | 5 °C / 41 °F | 55 °C / 131 °F |
|
|
|
Hard disk #3 | 5 °C / 41 °F | 55 °C / 131 °F |
|
|
|
Hard disk #4 | 5 °C / 41 °F | 55 °C / 131 °F |
|
|
|
Table 5.1 Temperature sensors |
|
|
Voltage level | Lower limit | Upper limit |
|
|
|
12 Volt | 10.8 V | 13.2 V |
|
|
|
5 Volt | 4.7 V | 5.3 V |
|
|
|
3.3 Volt | 3.1 V | 3.5 V |
|
|
|
Table 5.2 Power supply levels
5.9.2Logbook
The logbook menu is used to display a filtered history of system events.
Logbook filter
Set various filter criteria to search in a specified time period for various system events.