62 en Advanced configuration menu | Divar XF |
|
|
–Fixed duration: the profile override starts when the input becomes active and continues for the time set in the override duration field.
When a profile override is selected you then choose which of the six profiles is used and the override duration.
6.6Motion
The motion detection feature is configured by selecting the tabs for each individual analog video input. Motion detection on IP channels is possible but should be configured in the IP camera or encoder (if available).
Figure 6.7 Motion menu
1.To draw or delete an active motion detection area:
–Click an arrow in the Edit: field to select a motion area. Four areas can be drawn to detect motion in different areas of the camera image.
–Click Default to set the selected area to its default value.
–Click the Position, Width, and Height buttons to adjust the location and size of the motion area.
–Click Clear to delete the selected area.
–Select and define up to four areas.
2.The Motion indicator indicates the total level of detected motion within the active motion areas. A red marker indicates the peak level. Select Clear indicator to reset the peak level.
3.Adjust the Trigger level to set the motion sensitivity. If the motion indicator exceeds the trigger level, a motion event is generated.
F.01U.135.429 2.5 2009.08 | Installation manual | Bosch Security Systems |