GATE OPERATOR INSTALLATION

Concrete Pad Option

1. Follow the local building code to determine the required depth of the concrete pad.

2.Pad measurements recommended by Viking Access Systems are at least 23” long, 20” wide and 30” deep to ensure the stable operation of the operator, and a minimum of 6” above level grade to avoid any flooding of the machinery.

3.Provide a sufficient number of conduit pathways for all low power accessories such as loop detector leads, maglock, non-contact sensors, contact sensors, safety and other commands. Also provide conduit for the power supply to the operator.

!DO NOT run low voltage and high voltage wiring in the same conduit.

!Provide at least 12” separation between low and high voltage conduits.

1 4

VIKING TECHNICAL SUPPORT 1.800.908.0884

 

 

Image 16
Contents Instructions Viking F-1 Swing Gate Operator Vehicular Gate Operator Revision F1NXMN10.D October Parts Diagram DescriptionOperator References Limit Setup Buttons Control Board ReferencesTable of Contents Important Safety Instructions Important Safety InformationImportant Installation Instructions Important Installation Instructions Maintenance General Safety PrecautionsUL325 Gate Operator Classifications Install the gate operator only whenGlossary Photo Beam non-contact sensor Installation Secondary Entrapment Protection Edge Sensor contact sensor Installation When manual operation is required Manual Release To resume normal operationAudible Alarm Reset Switch Installation Manual Reset for the Audible AlarmSpecifications Single Phase 50Hz / 60HzAlternative Power 24VAC / VDC 60VA or Solar Locate Control ButtonsGate Operator Installation Concrete Pad OptionPost Mounting Option Required ADD-ON PART# VA-F1PSOperator Positioning Technical Tips Operator and Arm GeometryStep Tips for proper ground installation Electrical InstallationHigh Voltage Supply Option Low Voltage Supply Option Solar Supply OptionAt the Limit Cam & Holder assembly Limits Setup1a 1b Limits Setup Two Wire Communication MASTER/SLAVE SetupCable Requirements Wireless Communication Options Required ADD-ON Choose option a or BInitial Settings Timer Hold Open TimerODS Obstruction Detection SensorControl Board Setup Auto Open Power Failure OptionLast Open Power Failure Option Fail Safe ModeWhen the Obstruction Sensor detects an obstruction it will Obstruction Sensor Primary Entrapment ProtectionODS Obstruction Detection Sensor Flashing OverloadViking Lock Mode Use the LCD Display to activate this featureViking Heater To set the heater to turn on at the Close LimitThis page Left Blank Intentionally Accessory Connections Re-Open Photo Beam vehicular SafetyCOM + Check for proper operationOpen-Stop-Close Radio Receiver TypicalOpen Only Anti-Tailgate, Open Commands & Guard Station Open CommandsGuard Station ATG Anti-TailgateViking Loop Rack Accessory Connections Guidelines for Loop InstallationMagnetic Lock, Lock Solenoid Power for the LocksMagnetic Lock Lock Solenoid Synchronization with B-12 Barrier Arm B-12 Synchronization OptionTroubleshooting LED ReferencesTroubleshooting LCD MSG Meaning LCD Display ReferencesTroubleshooting Error Messages Solutions CheckAccess Control Connections Power ConnectionsAppendix a Relays In GeneralGeneral Technical TIP Viking usesCommon Radio Receivers Connections Appendix C Solar ApplicationsPanels Batteries & FuseViking Expansion Products Viking Konnect Diagnostic Tool On-site remoteViking Konnect Master/Slave Kit Secure and reliable OUR Continuous Commitment to Excellence Standard Features