ACCESSORY CONNECTIONS

Guidelines for Loop Installation

1. Prevent sharp corners in the geometry of the loop sensor.

2. Install the appropriate number of turns for your loop geometry based on the loop perimeter. Use Table C (below) as a guide.

3. Use XLP (cross-linked-polyethylene) type of wire. This wire reduces the effects of moisture and other environmental events in altering the functionality of the vehicular loop detector.

4. Twist the lead wire at least 6 turns per foot.

5. Use BACKER-ROD to minimize damage to the loop detector wire prior to using the sealant.

6. Place the loop detector wire and adjust the sensitivity of the vehicular loop detector unit in a way to minimize the effects of the gate over the loop detector wire.

! IMPORTANT! Some of the following parameters may affect the proper functionality of the vehicular loop detector.

Consult the manufacturer of the vehicular loop detector and/or loop wire.

• Gate size

• Number of turns in the loop sensor wire

• Distance of the loop sensor wire to the gate at either at the open or close position

Table C - Recommended Number of Turns

Perimeter (ft.)

Number of Turns

 

 

 

105

204

30-403

50-1002

 

5'

Dimension “A” - 5’ for Single Gate

 

 

 

6’ for Dual Gate

A

A

5'

5'

Outside

Center

Inside

Exit

Reopen

Reopen

Loop

Loop

Loop

Loop

 

 

 

5'

Make Even

 

 

with Open Gate

 

 

 

Gate in Open Position

 

VIKING TECHNICAL SUPPORT 1.800.908.0884

3 3

 

 

Image 35
Contents Instructions Viking F-1 Swing Gate Operator Vehicular Gate Operator Revision F1NXMN10.D October Description Parts DiagramOperator References Control Board References Limit Setup ButtonsTable of Contents Important Installation Instructions Important Safety InformationImportant Safety Instructions Important Installation Instructions General Safety Precautions MaintenanceGlossary Install the gate operator only whenUL325 Gate Operator Classifications Secondary Entrapment Protection Photo Beam non-contact sensor InstallationTo resume normal operation Edge Sensor contact sensor InstallationWhen manual operation is required Manual ReleaseManual Reset for the Audible Alarm Audible Alarm Reset Switch InstallationLocate Control Buttons SpecificationsSingle Phase 50Hz / 60Hz Alternative Power 24VAC / VDC 60VA or SolarConcrete Pad Option Gate Operator InstallationRequired ADD-ON PART# VA-F1PS Post Mounting OptionTechnical Tips Operator and Arm Geometry Operator PositioningStep High Voltage Supply Option Electrical InstallationTips for proper ground installation Solar Supply Option Low Voltage Supply Option1a 1b Limits SetupAt the Limit Cam & Holder assembly Limits Setup Cable Requirements MASTER/SLAVE SetupTwo Wire Communication Required ADD-ON Choose option a or B Wireless Communication OptionsObstruction Detection Sensor Initial SettingsTimer Hold Open Timer ODSFail Safe Mode Control Board SetupAuto Open Power Failure Option Last Open Power Failure OptionFlashing Overload When the Obstruction Sensor detects an obstruction it willObstruction Sensor Primary Entrapment Protection ODS Obstruction Detection SensorTo set the heater to turn on at the Close Limit Viking Lock ModeUse the LCD Display to activate this feature Viking HeaterThis page Left Blank Intentionally Check for proper operation Accessory ConnectionsRe-Open Photo Beam vehicular Safety COM + Open Only Radio Receiver Typical Open-Stop-Close ATG Anti-Tailgate Anti-Tailgate, Open Commands & Guard StationOpen Commands Guard StationViking Loop Rack Guidelines for Loop Installation Accessory ConnectionsMagnetic Lock Lock Solenoid Power for the LocksMagnetic Lock, Lock Solenoid Barrier Arm B-12 Synchronization Option Synchronization with B-12LED References TroubleshootingTroubleshooting LCD Display References LCD MSG MeaningTroubleshooting Error Messages Check SolutionsPower Connections Access Control ConnectionsTechnical TIP Viking uses Appendix aRelays In General GeneralCommon Radio Receivers Connections Batteries & Fuse Appendix CSolar Applications PanelsViking Konnect Master/Slave Kit Secure and reliable Viking Konnect Diagnostic Tool On-site remoteViking Expansion Products OUR Continuous Commitment to Excellence Standard Features