Viking Access Systems f1 gate manual Parts Diagram, Description

Page 4

PARTS DIAGRAM:

Item

Description

Part No.

1

Operator Cover Bolt (2)

VASWCB

2

Operator Cover

VNXF1CV

3

Output Shaft Knob

DWOUK10

4

Output Shaft Cover

VNXSWOSC

5

Clutch Key

VAWRCK20

6

Clutch and Handle

DWCL20

7

Output Arm

DWAR20

8

Output Shaft

DWOP20

9

Control Board

VFLEXPCB

10

Fuse - 15 amp

VNXF15A

11

Fuse - 4 amp

VNXF4A

12

Limit Switch Holder

DWLH10

13

Limit Switch (2)

DULS10

14

Limit Cam & Holder

DWLC10

15

Worm Gear #70 10:1

DWGB70

16

41B30 3/4 Sprocket (Gear)

VASP3034

17

Chain #40x46 Pitches

DWCA10

18

41B10 3/4 Sprocket (Motor)

VASP1034

19

24V DC Gearhead Motor

VAF1MO

20

Brush Kit

VAMBK

21

Chassis

VNXF1CH

22

Loop Rack

VA-LR

23

Battery Switch

DUMRS10

24

Motor Switch

DUMRS10

25

Battery

DUBA12

26

Modular Power Box Assembly

VNXMPB

27

Toroid Transformer - 10 amp

DUTT10

28

Power Box Panel Assembly

VNXUPBPA

29

120V Receptacle

VA120PL

30

Main Power Switch

DUMRS10

31

Alarm

DUAL10

32

Power Harness

VNXSWPH

33

Limit Switch Harness

VNXF1LSH

34

Multi-Part Arm Assembly (Standard)

VA-F1ARM20

Option Swivel Arm Assembly (for inclines up to 10°)

VA-F1SWL20

2

VIKING TECHNICAL SUPPORT 1.800.908.0884

 

 

Image 4
Contents Instructions Viking F-1 Swing Gate Operator Vehicular Gate Operator Revision F1NXMN10.D October Parts Diagram DescriptionOperator References Limit Setup Buttons Control Board ReferencesTable of Contents Important Safety Instructions Important Safety InformationImportant Installation Instructions Important Installation Instructions Maintenance General Safety PrecautionsUL325 Gate Operator Classifications Install the gate operator only whenGlossary Photo Beam non-contact sensor Installation Secondary Entrapment ProtectionEdge Sensor contact sensor Installation When manual operation is requiredManual Release To resume normal operationAudible Alarm Reset Switch Installation Manual Reset for the Audible AlarmSpecifications Single Phase 50Hz / 60HzAlternative Power 24VAC / VDC 60VA or Solar Locate Control ButtonsGate Operator Installation Concrete Pad OptionPost Mounting Option Required ADD-ON PART# VA-F1PSOperator Positioning Technical Tips Operator and Arm GeometryStep Tips for proper ground installation Electrical InstallationHigh Voltage Supply Option Low Voltage Supply Option Solar Supply OptionAt the Limit Cam & Holder assembly Limits Setup1a 1b Limits Setup Two Wire Communication MASTER/SLAVE SetupCable Requirements Wireless Communication Options Required ADD-ON Choose option a or BInitial Settings Timer Hold Open TimerODS Obstruction Detection SensorControl Board Setup Auto Open Power Failure OptionLast Open Power Failure Option Fail Safe ModeWhen the Obstruction Sensor detects an obstruction it will Obstruction Sensor Primary Entrapment ProtectionODS Obstruction Detection Sensor Flashing OverloadViking Lock Mode Use the LCD Display to activate this featureViking Heater To set the heater to turn on at the Close LimitThis page Left Blank Intentionally Accessory Connections Re-Open Photo Beam vehicular SafetyCOM + Check for proper operationOpen-Stop-Close Radio Receiver TypicalOpen Only Anti-Tailgate, Open Commands & Guard Station Open CommandsGuard Station ATG Anti-TailgateViking Loop Rack Accessory Connections Guidelines for Loop InstallationMagnetic Lock, Lock Solenoid Power for the LocksMagnetic Lock Lock Solenoid Synchronization with B-12 Barrier Arm B-12 Synchronization OptionTroubleshooting LED ReferencesTroubleshooting LCD MSG Meaning LCD Display ReferencesTroubleshooting Error Messages Solutions CheckAccess Control Connections Power ConnectionsAppendix a Relays In GeneralGeneral Technical TIP Viking usesCommon Radio Receivers Connections Appendix C Solar ApplicationsPanels Batteries & FuseViking Expansion Products Viking Konnect Diagnostic Tool On-site remoteViking Konnect Master/Slave Kit Secure and reliable OUR Continuous Commitment to Excellence Standard Features