Sanyo VCC-WB2000 Network SET Settings, Set the password, Username, ID1 ID2 ID3, Access level

Page 19

Network Camera Settings

A NETWORK SET Settings

These settings are used in order to connect the camera to the network.

Note: Check with the network system administrator for details on settings related to the network itself, such as IP address settings.

1

2

3

4

1 Click the [NETWORK] button in the main menu.

The initial NETWORK SET window will be displayed. The default settings for each item will be displayed automatically. Check with the network system administrator or Internet Service Provider if you need to change any of the following settings.

IP ADDRESS

SUBNET MASK

GATEWAY

Default settings displayed

Reset if necessary

2 Set the password.

There are three access levels available (User, Operator and Administrator) and separate passwords can be set for each level. The range of operations varies for each level as shown in the table below.

Username

ID1

ID2

ID3

Access level

User

Operator

Adminis-

 

 

 

trator

Password

1111

2222

3333

(default)

 

 

 

Live image

F

F

F

viewing

 

 

 

Menu

T

F

F

settings

 

 

 

Main menu

 

 

 

button

T

v

F

operation

 

 

 

 

 

 

 

v: Camera settings only

Note: The passwords are set as shown in the table above at the time of shipment from the factory. However, it is recommended that you change them whenever possible for security purposes.

3 Once you have finished changing the settings, click the [SET] button.

– 18 –

English

Image 19
Contents Network Camera VCC-WB2000Contents Information to user Safety GuardPrecautions Accessories FeaturesOperating environment Lens mount cap Monitor OUT connectorPower indicator Name and Function of Each PartName and Function of Each Part Attach the CS mount-type lens Attaching the LensFor C mount type Turn on the camera’s power Flange Back AdjustmentBasic Connections ConnectionsRemoving the wireless LAN card Inserting the wireless LAN cardConnections PPP Dial-up Connections Network Camera Settings Installation of Plug-in Software Network Camera SettingsUninstalling the plug-in software Click the Install buttonClick the Finish button Cookie Settings Browser SettingsCamera uses cookies Computer and Camera Settings Click the Network button in the main menu Network Connection SettingsClosing the initial window Sanyo Network CAMERA, the Unit isUsername Network SET SettingsSet the password Access levelHttp Port Number Network SpeedCurrent Channel Wireless LAN SET SettingsEncryption KEY WEP EnciphermentType in the commands to use for controlling the modem PPP SET SettingsData Size AuthenticationCircuit Type Baud RateAUTO/FINE radio buttons Menu Screen and Main MenuCAMERA, the Unit is Disconnected Menu Screen and Main MenuOpening and Closing the Initial Screen Viewing Camera ImagesViewing Camera Images When you have finished, click the network disconnect buttonSelect the language and then click the SET button Lit green Netcam Live View SettingsClock Unset indicator Click the Live View button in the main menuResolution Expansion Live View SettingsSaving Images into a Computer Click the View Frame button in the main menu View Frame OperationsBack button Iris Camera SettingsLive Image Camera TitleWhite Balance Camera SettingsBright Electronic ShutterType in the new camera title e.g. CAM1 Setting the camera titleClick the SET button Change the External Alarm setting to NC or no Alarm SettingExternal Alarm Sensor Settings Click the Alarm button in the main menuAlarm Setting Picture Quality Motion Detector SET SettingsTime Removing the memory card Alarm Data Recording CapacityExpansion memory cards Inserting the memory cardPlaying Back Alarm Data Recording Alarm DataClick the Alarm Data indicator while it is red or green Buffer Data View screen Playing Back Expansion Memory Card Images Deleting Alarm ImagesClick the Delete button Pre-alarm and Post-alarm Recording Timezone Clock SET SettingsDaylight Saving Mode Clock SETSUB-MICROCOMPUTER Version RS-232C Settings RS-232C SETStatus Checking Firmware VersionIf you forget the IP Address TroubleshootingIs the link indicator flashing? If the camera cannot be connectedSpecifications Dimensions Specifications136 mm 85 mm 126 mm 57 mm 12 mm 51 mm Exclusions Page Page Printed on recycled paper 1AC6P1P2545 L5AB2/US 0702KP-CZ