Sanyo VCC-WB2000 instruction manual Live View Settings, Resolution Expansion

Page 30

LIVE VIEW Settings

2Live image transmission settings

Select the required setting from the respective drop-down list boxes, and then click the [SET] button.

AFRAME RATE setting

This lets you set the image transmission speed to one of five settings. Images can be transmitted at maximum speed depending on the network environment that the camera is connected to. The default setting is “STEP 5”.

Note: For example, if the maximum transmission speed for the network being connected to is 15 fps, then the images can only be transmitted at a maximum speed of 15 fps, even if the frame rate is set to “STEP 4” or higher.

(Guide to maximum speed)

Menu

Maximum

STEP1

5 fps

STEP2

10 fps

 

 

STEP3

15 fps

 

 

STEP4

20 fps

STEP5

30 fps

 

 

BCOMPRESSION RATIO setting

This lets you set the compression ratio to one of five settings. If a higher compression ratio is used (STEP 1), the volume of image data becomes smaller (the amount of image deterioration becomes greater) and the transmission speed becomes faster.

The default setting is “STEP 3“.

Note: Alarm image recording is carried out at the compression ratio that is specified in the alarm recording settings, not at the setting that is made here.

CRESOLUTION setting

This lets you set the image resolution to one of five settings. The higher the resolution (720x480), the larger is the volume of data. The default setting is “640x480”. The size of the live image screen changes each time the resolution setting is changed.

Note:

When images that are compressed using JPEG2000 are played back, the image refresh rate will vary depending on the performance specifications of the computer being used. In addition, if other applications besides the web browser are running, this may also cause the image refresh rate to become slower or may result in unstable operation. You should avoid running other applications at the same time as much as possible.

Alarm image recording is carried out at the resolution that is specified in the alarm recording settings, not at the setting that is made here.

DEXPANSION setting

This lets you set the enlargement ratio (x2 or x4) for the live image screen. The enlargement ratio will vary depending on the RESOLUTION setting. (Table 1)

(Table 1)

RESOLUTION

EXPANSION

160 x 120

x2, x4

320 x 240

x2

 

 

640 x 480

x1 only

 

720 x 480

 

Note: The images are enlarged to the resolution that is set by the RESOLUTION setting, and the images become coarser.

English

– 29 –

Image 30
Contents VCC-WB2000 Network CameraContents Safety Guard Information to userPrecautions Features AccessoriesOperating environment Name and Function of Each Part Monitor OUT connectorPower indicator Lens mount capName and Function of Each Part Attaching the Lens Attach the CS mount-type lensFor C mount type Flange Back Adjustment Turn on the camera’s powerConnections Basic ConnectionsInserting the wireless LAN card Removing the wireless LAN cardConnections PPP Dial-up Connections Network Camera Settings Network Camera Settings Installation of Plug-in SoftwareClick the Install button Uninstalling the plug-in softwareClick the Finish button Browser Settings Cookie SettingsCamera uses cookies Computer and Camera Settings Sanyo Network CAMERA, the Unit is Network Connection SettingsClosing the initial window Click the Network button in the main menuAccess level Network SET SettingsSet the password UsernameNetwork Speed Http Port NumberWireless LAN SET Settings Current ChannelWEP Encipherment Encryption KEYPPP SET Settings Type in the commands to use for controlling the modemBaud Rate AuthenticationCircuit Type Data SizeMenu Screen and Main Menu AUTO/FINE radio buttonsMenu Screen and Main Menu CAMERA, the Unit is DisconnectedViewing Camera Images Opening and Closing the Initial ScreenWhen you have finished, click the network disconnect button Viewing Camera ImagesSelect the language and then click the SET button Click the Live View button in the main menu Live View SettingsClock Unset indicator Lit green NetcamLive View Settings Resolution ExpansionSaving Images into a Computer View Frame Operations Click the View Frame button in the main menuBack button Camera Title Camera SettingsLive Image IrisElectronic Shutter Camera SettingsBright White BalanceSetting the camera title Type in the new camera title e.g. CAM1Click the SET button Click the Alarm button in the main menu Alarm SettingExternal Alarm Sensor Settings Change the External Alarm setting to NC or noAlarm Setting Motion Detector SET Settings Picture QualityTime Inserting the memory card Alarm Data Recording CapacityExpansion memory cards Removing the memory cardRecording Alarm Data Playing Back Alarm DataClick the Alarm Data indicator while it is red or green Buffer Data View screen Deleting Alarm Images Playing Back Expansion Memory Card ImagesClick the Delete button Pre-alarm and Post-alarm Recording Clock SET Clock SET SettingsDaylight Saving Mode TimezoneFirmware Version RS-232C Settings RS-232C SETStatus Checking SUB-MICROCOMPUTER VersionIf the camera cannot be connected TroubleshootingIs the link indicator flashing? If you forget the IP AddressSpecifications Specifications Dimensions136 mm 85 mm 126 mm 57 mm 12 mm 51 mm Exclusions Page Page Printed on recycled paper 1AC6P1P2545 L5AB2/US 0702KP-CZ