Sanyo VCC-WB2000 Attaching the Lens, Attach the CS mount-type lens, For C mount type

Page 8

Attaching the Lens

Use a DC-type automatic iris-type lens (sold separately).

1 Remove the lens mount cap.

3 Connect the lens iris plug to the lens iris output connector of the camera.

Lenses from other manufacturers may have different plug shapes and specifications. In such cases, you may need to rewire the lens iris plug.

1 (–) control coil

3 (+) drive coil

2 (+) control coil

4 (–) drive coil

2 Attach the CS mount-type lens.

Note:

The “L” part of the lens should be 5 mm or less in

length. If a lens that does not

conform to this standard isL used, it will not be possible to

attach the lens correctly.

Gently screw the lens into the camera.

The following automatic iris-type lenses can be used.

VCL-CS8LY (standard, f = 8 mm)

VCL-CS4LY (wide angle, f = 4 mm)

VCL-CS2LY (extra wide angle, f = 2.8 mm)

2

1

2

1

 

 

43

4 3

(Connecting to the lens iris plug)

1Cut off the plug of the lens cable, cut off approximately 8 mm of the insulation, and then strip the ends of the cable sheaths leaving approximately 6 mm of sheath intact.

2Solder the ends of the cable wires to the ends of the pins, and then attach the cover of the lens iris plug.

3

2

For C mount type

In order to allow correct adjustment of the flange back, attach the C mount adapter ring (option) to the lens before attaching the lens to the camera.

English

– 7 –

Image 8
Contents VCC-WB2000 Network CameraContents Safety Guard Information to userPrecautions Operating environment FeaturesAccessories Monitor OUT connector Power indicatorName and Function of Each Part Lens mount capName and Function of Each Part For C mount type Attaching the LensAttach the CS mount-type lens Flange Back Adjustment Turn on the camera’s powerConnections Basic ConnectionsConnections Inserting the wireless LAN cardRemoving the wireless LAN card PPP Dial-up Connections Network Camera Settings Network Camera Settings Installation of Plug-in SoftwareClick the Finish button Click the Install buttonUninstalling the plug-in software Camera uses cookies Browser SettingsCookie Settings Computer and Camera Settings Network Connection Settings Closing the initial windowSanyo Network CAMERA, the Unit is Click the Network button in the main menuNetwork SET Settings Set the passwordAccess level UsernameNetwork Speed Http Port NumberWireless LAN SET Settings Current ChannelWEP Encipherment Encryption KEYPPP SET Settings Type in the commands to use for controlling the modemAuthentication Circuit TypeBaud Rate Data SizeMenu Screen and Main Menu AUTO/FINE radio buttonsMenu Screen and Main Menu CAMERA, the Unit is DisconnectedViewing Camera Images Opening and Closing the Initial ScreenSelect the language and then click the SET button When you have finished, click the network disconnect buttonViewing Camera Images Live View Settings Clock Unset indicatorClick the Live View button in the main menu Lit green NetcamLive View Settings Resolution ExpansionSaving Images into a Computer Back button View Frame OperationsClick the View Frame button in the main menu Camera Settings Live ImageCamera Title IrisCamera Settings BrightElectronic Shutter White BalanceClick the SET button Setting the camera titleType in the new camera title e.g. CAM1 Alarm Setting External Alarm Sensor SettingsClick the Alarm button in the main menu Change the External Alarm setting to NC or noAlarm Setting Time Motion Detector SET SettingsPicture Quality Alarm Data Recording Capacity Expansion memory cardsInserting the memory card Removing the memory cardClick the Alarm Data indicator while it is red or green Recording Alarm DataPlaying Back Alarm Data Buffer Data View screen Click the Delete button Deleting Alarm ImagesPlaying Back Expansion Memory Card Images Pre-alarm and Post-alarm Recording Clock SET Settings Daylight Saving ModeClock SET TimezoneRS-232C Settings RS-232C SET Status CheckingFirmware Version SUB-MICROCOMPUTER VersionTroubleshooting Is the link indicator flashing?If the camera cannot be connected If you forget the IP AddressSpecifications 136 mm 85 mm 126 mm 57 mm 12 mm 51 mm SpecificationsDimensions Exclusions Page Page Printed on recycled paper 1AC6P1P2545 L5AB2/US 0702KP-CZ