7. 2 Menus
• Select the menu to change the setting by referring the item "7.1 Using the Menues".)
• When the [MENU UP], [MENU DOWN] buttons are pushed, the "→ " on the screen moves up and down. Move the "→ " to the item to change.
( 1 ) SHUTTER (Electronic shutter)
The electronic shutter has three modes; MANU (Manual), SS (Synchro. Scan), EXT TRIG (External trigger).
Set the "→ " to "MODE" and push [DATA UP], {DATA DOWN] button to select the desired mode among "MANU", "SS", "EXT TRIG".
(1. 1) Changing each setting in MANU mode
Move up down |
| Set by pushing | ||||||
By pushing |
| |||||||
| DATA UP, DOWN | |||||||
MENU UP, DOWN |
| |||||||
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
MODE | MANU |
MANU | 50000 |
PART | OFF |
<MODE = MANUAL>
•Shutter mode MANU, SS, E.TRG
•Shutter speed setting
OFF, 100 (1/100s), 250 (1/250s), 500 (1/500s) 1000 (1/1000s), 2000 (1/2000s), 4000 (1/4000s) 10000 (1/10000s), 25000 (1/25000s)
50000 (1/50000s)100000 (1/100000s)
*100 (1/100s) may not be specified at PART (Partial read) ON setting.
• Partial read switch OFF/ON
(a) Changing the shutter speed
1Set the "→ " to MANU by pushing [MENU UP], [MENU DOWN] buttons.
2Set the shutter speed by pushing [DATA UP], [DATA DOWN] buttons.
(b) Partial read setting
1Set the "→ " to PART by pushing [MENU UP], [MENU DOWN] buttons.
2Select either OFF or ON by pushing [DATA UP], [DATA DOWN] buttons.
12