Toshiba IK-TF5 1P SR 1 Pulse Sync Reset, Pulse Trigger SYNC-RESET Picture Output Timing

Page 26

( 2 ) 1P SR (1 Pulse Sync Reset)

Charge begins to accumulate after the trigger input to the RGB terminal, the vertical sync signal is reset and field images are output.

(2. 1) 1 Pulse Trigger SYNC-RESET Picture Output Timing

Negative polarity mode

Trigger*1

Positive polarity mode

About 1 s

Exposure period*2

Exposure completion

to 1H*3

VD OUT

Video output

VIDEO INDEX

525H (Partial scanning OFF)

175H (Partial scanning ON)

*1: Externally input signal

*2: Exposure time is determined by the setting of "(1.3) Changing each setting in E.TRG mode".

*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro- nized to this and output.

Note:

When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.

26

Image 26
Contents IK-TF5 For Customer UseSafety Precautions Disclaimer May occur in such placesTable of Contents Components Items Controlled by Using on Screen Display Available selectins Preset valueMenu Down button Standard Connection Connector Pin AssignmentsConnection Automatic White Balance Manual White Balance Outline OperationWhite Balance Result displayed MeaningShading Correction Shutter speed mode is EXT Trig modeGain Mode Setting by on Screen Display Using the MenusMenus Changing each setting in Manu modePartial read setting Shutter Electronic shutterChanging each setting in SS synchro. scan mode Changing the shutter speed settingChanging the polarity of inputting trigger pulse setting Changing each setting in E.TRG modeChanging each setting in 1P SNR mode Changing 1P SNR exposure time settingChanging each setting in 1P SR mode Changing 1P SR exposure time settingChanging each setting in PW SNR mode Changing each setting in PW SR mode Changing the gain in Manu mode Changing each setting in RR modeChanging each setting in Gain Gain Video gainWHT BAL White balance Changing R pedestal Changing shading correction modeChanging master pedestal Changing B pedestalOption Adjusting horizontal phaseSync Changing RGB SyncShutter mode HD input VD input Setting to factory setting statusExternal sync signal input conditions External SyncSetting by 1H Setting by the frameUsing the unit with external sync signal Synchro. Scan Operation1P SNR 1 Pulse Sync Non Reset EXT Trig External triggerVD OUT*3 Video Index 1P SR 1 Pulse Sync Reset 1 Pulse Trigger SYNC-RESET Picture Output TimingPW SNR Pulse width trigger SYNC-NON Reset Video output 525H PW SR Pulse width trigger SYNC-RESET 1 Pulse Width Trigger SYNC-RESET Picture Output TimingLong Term Exposure RR Reset restartInput Timing Chart Example Partial Scanning OFF All pixels scanning When Partial Scanning Mode is onPartial Read Partial Scanning onInput Output Signal Specificatoins Vertical Output Waveform Timing Chart CCD Output Waveform Timing ChartHorizontal Output Waveform Timing Chart Specifications RGB, 3CCDSymptom Items to be checked External Appearance DiagramBefore Making a Service Call Imaging Systems Division Limited One 1 Year Warranty of Labor and PartsStep-by-step Procedures How to Obtain Warranty Service